Normal Part (FM-X) Edit
A Normal Part (FM-X) can consist of up to eight Operators. There are two types of Normal Part (FM-X) Edit
displays: Operator Common Edit display, for editing settings common to all eight Operators; and Operator
Edit display, for editing individual Operators.
Operator Common Edit (Common)
From the General display you can set various parameters such as Part Name, Volume, and Pan.
Most parameters are the same as parameters on the Element Common Edit display for Normal Parts
(AWM2) (
) except the following additional parameters as bellows.
Random Pan
Determines the amount by which the sound of the selected Operator is panned randomly left and right for
each note you press. The Pan setting is used as the Center Pan position.
Settings:
0 – 127
Alternate Pan
Determines the amount by which the sound of the selected Operator is panned alternately left and right for
each note you press. The Pan setting is used as the basic Pan position.
Settings:
L64 – C – R63
Scaling Pan
Determines the degree to which the notes (specifically, their position or octave range) affect the Pan
position, left and right, of the selected Operator. At note C3, the main Pan setting is used for the basic Pan
position. Positive settings will cause the Pan position to be set left when you play in the lower range on the
keyboard and to be set right when you play in the higher range on the keyboard. A negative setting will
have the opposite effect.
Settings:
-64 – +0 – +63