Wordclock Setup
217
03D—Owner’s Manual
AUTO NAVIGATE
—This function checks all possible word-
clock sources and then displays a dialog box recommending a
suitable source. Note, however, that this function is not perfect
and in some situations it may not be able to recommend a suit-
able source. The dialog box shown here appears when this func-
tion is selected.
MANUAL
—These options allow you to select the wordclock source.
Internal wordclock at 44.1 kHz
Internal wordclock at 48 kHz
External wordclock via the DIGITAL STEREO IN (AES/EBU or Coaxial).
The STEREO INPUT ASSIGN FLIP switch on the D.in Setup page must be
set so that the AES/EBU or Coaxial signal is assigned to the ST IN.
External wordclock via the BNC WORD CLOCK IN connection
External wordclock via the YGDAI card inputs 1 and 2
External wordclock via the YGDAI card inputs 3 and 4
External wordclock via the YGDAI card inputs 5 and 6
External wordclock via the YGDAI card inputs 7 and 8
The status of these wordclock sources appear as follows.
03D locked to this wordclock source
Usable wordclock present
Wordclock signal present but not synchronized to selected wordclock. If such
a signal is connected and the DIGITAL ST IN SYNC CAUTION or YGDAI IN
SYNC CAUTION preference is set to ON, a warning message appears. See
03D Preferences on page 213 for more information.
No wordclock signal available.
FS
—When the 03D is locked to a wordclock, the sampling rate appears here (48k,
44.1k, or 32k). When it is unlocked, the display shows UNLOCK. If another page is
accessed in the unlocked state, UNLOCK appears on that page too.