19
■
NDP-P25 (plastic type) series
NDP-P25
Type
BP
□
BPT BV
□
BVT
Nominal Diameter
1
˝
(25 mm)
Suction Port
Fluid
Connection
Discharge
Port
BSP 1 or Equivalent to DIN flange DN25 PN10
Supply Port
Rc 3/8
Air
Connection
Exhaust Port
Rc 3/4
Operating Air Pressure *
1
0.2~0.7 MPa
Maximum *
1
Discharge Pressure
0.7 MPa
Discharge Volume/cycle *
2
600 mL
500 mL
600 mL
500 mL
Maximum Discharge Volume
160 L/min
Maximum Air Consumption
1600 L/min(ANR)
1800 L/min(ANR)
1600 L/min(ANR)
1800 L/min(ANR)
Slurry Limitation
3 mm or less
Limitation of Viscosity
Suction Lift 3Pa·s or below
Force In 8Pa·s or below
Temp. 0~70
˚
C
Operating
Ambient
Temperature
Range
Fluid
Temp.
0~60
˚
C
A-weighted emission sound
pressure level *
3
86 dB
A-weighted sound power level
*
4
96 dB
Weight
9.5 kg
12.0 kg
*1. Maximum air pressure for non-metallic pumps decreases with temperature (See 20 page of “Temperature
Pressure Curve”).
*2. Discharge Volume/cycle is highly dependent on application. Contact your local distributor or Yamada for
more information.
*3. The measuring method is based on ISO 3744.