YAMADA FB-8 Instruction Manual Download Page 2

Symptom

Cause

Corrective Measure

Bucket is empty

Fill the grease

Air is trapped in the grease

Remove the air

Pump and hose is clogged with foreign substance Remove the foreign substance
Viscosity of the grease is too high

Use lower viscosity grease

Pump and hose is clogged with foreign substance Remove the foreign substance

Pump does not discharge
the grease

Grease discharge volume
is low

Model No.

Description

Q'ty

GC81007 Grease Hose 1/4”x2m

1

686830 GLC-70 Grease Lock Coupler

1

Model No.

Description

GC81008 Grease Hose 1/4”x3m
GC81010 Grease Hose 1/4”x5m

Model No. Model

Maximum working

pressure

Dimensions

Weight Capacity Usable 

grease

686833

FB-8

69MPa

452×239×450mm

8.6 kg

8 kg

NLGI No.0

2 *

Discharge pressure

Discharge volume

When depressed at 40kg

2.7 mL/stroke

 

 

FOOT OPERATED GREASE PUMP 

 

FB-8  ITEM

 

No.686833 

 

-

 

Precautions on Use

 

The following warnings and cautions are very important. Be sure to observe them. 

 

<WARNING>

 

Gasoline is a high-volatility fuel. Do not use it to clean the pump in 
any case. Otherwise, ignition or explosion may be caused. 

Grease will be discharged at high pressure. Do not turn it toward 
yourself or people. It may cause of injury. 

Wear thick (e.g. leather) gloves, safety goggles, safety helmet, etc. 

If grease gets into your body or eyes, seek medical attention 
immediately. Grease adhering to the skin can cause inflammation 
and thus must be washed out sufficiently with water and soap. 

Please handle grease properly according to the instruction manual 
and SDS of grease maker. 

<CAUTION>

                                                                                           

   

Do not use with other than grease, such as solvent. 

Use of high viscosity grease will produce air pockets and result in 
operation failure. Remove the air pocket in that case. 

-

 

Preparations before Operation

 

Keep away the grease from dust. 

1. 

Open the lid. 

2. 

After wiping the inside of the bucket by clean cloth, fill 

the grease and close the lid. (Fig.1) 

3. 

Tap the pump on a firm surface to displace air pocket 
trapped in the base of the bucket. (Fig.2)

 

 

4. 

Operate the pump by stepping on the foot lever a few 
times until grease comes out. 

 

NOTE

  Air-mixed grease becomes cloudy white. 

 

1.

 

Part Names

 

 

 

 

 

 

 

 

 

 

2.

 

Instructions 

Do not use on damaged or broken grease fittings. Grease fittings 
may fracture and it may cause injury by high pressure grease.

 

1. 

  Press the lever of Grease Lock Coupler.

                                     

 

Slide the coupler onto grease fitting and   
release the lever to connect. 

 

2. 

  Step on the foot lever for greasing .

 

 

3. 

  After finishing the greasing, push the foot     

lever upward to release residual pressure   
in the hose. 

4. 

  Press the lever again to disconnect the 

coupler from grease fitting.   

 

 3.

 

Maintenance and Inspection

 

<CAUTION>

                                                           

Gasoline is a high-volatility fuel. Do not use it to clean the pump in 
any case. Otherwise, ignition or explosion may be caused. 

Troubleshooting and Corrective Measures

 

 

 

Spare Parts

 

 

 

4.

 

Main specifications 

 

 [

Specifications

]  

 
        
 

 

Usable range of NLGI No. is a rough indication.                 

  The range may be different depending on property of the grease. 

                         

 

[

Pump Specifications

 

[

Optional Accessories

]

 

 

 
 
 

5.

 

Limited Warranty

 

 

If an abnormality occurs during normal operation in accordance with the operating 

instructions and other operating cautions within the warranty period (12 months after 
date of purchase) that can be attributed to a manufacturing defect, the defective 
parts of this product will be serviced or the product will be replaced free of charge. 
However, this warranty will not cover compensation for incidental damage or any 
malfunction listed below. 

1. 

Warranty period 

This warranty will be valid for a period of 12 months after the date of purchase. 

2. 

Warranty 

If, during the warranty period, any of the material of the genuine parts of this product or 
the workmanship of this product is found defective, and is so verified by our company, the 
servicing cost will be fully born by our company.

 

3. 

Exclusion 

Even during the warranty period, this warranty does not cover the following. 

1. Malfunction arising from use of parts other than manufacturer-specified genuine parts 

2. Malfunction arising from misuse or operating errors, or lack of storage or maintenance 

care 

3. Malfunction arising from use with a fluid that may cause corrosion, inflation or 

dissolution of the component parts of the product 

4. Irregularity arising from repair made by other than by our firm, our regional office, 

dealer or authorized service personnel 

5. Malfunction arising from modification of the product by other than authorized 

service personnel 

6. Wear and tear of parts that must be regularly replaced in in the course of normal 

operation, such as packings, O-rings and hose. 

7. Malfunction and/or damage due to use with incorrect voltage. 
8. Malfunction and/or damage due to transportation, moving or drop page of the product 

after purchase 

9. Malfunction and/or damage due to fire, earthquake, flood or other force majeure 

10. Malfunction arising from use of compressed air that contains impurities or excessive 

moisture, or use of gases or fluids other than the specified compressed air 

11. Malfunction arising from use of excessively abrasive material or of inadequate grease.  

Furthermore, this warranty does not cover the rubber parts, or other parts used in this 

product and its accessories, which are subject to wear in normal operation. 

hoses

    ・

packings 

  ・

cords

 

 

4. 

Parts 

Parts for this product will be kept available for 5 years after discontinuation of production. 

Once 5 years have elapsed after close of production, availability of parts for this 
product cannot be guaranteed.

   

 

 

No.1-3, 1-Chome, Minami-magome, Ota-ku, Tokyo 143-8504 Japan 
Phone: +81-(0)3-3777-0241    

       

Fax

       

: +81-(0)3-3777-0584 

E-mail: [email protected]    URL: www.yamadacorp.co.jp/global 

 

YAMADA (THAILAND) Co., Ltd.

 

41/79 Moo 6, Bangna-Trad Rd., Bangchalong, Bangplee,Samutprakarn 10540 Thailand 
Phone: +66-(0)2-130-0990      Fax

       

: +66-(0)2-130-0993 

E-mail: [email protected]   

   

URL: www.yamadacorp.co.jp/global

 

INSTRUCTION MANUAL

 

Fig.1

 

Fig.2

 

Grease Lock Coupler 

Grease Hose 

Coupler Holder 

Foot Lever 

Handle 

Bucket 

Lid 

Summary of Contents for FB-8

Page 1: ...レバーを押して カプラーを給脂先のグリースニップルに固定 します 2 レバーから手を離し フットペダルを踏んで グリースアップを行います 3 グリースアップが終わりましたら フットレバ ーを足で押し上げて 圧抜きを行ってください 4 レバーを押して カプラーをグリースニップル から取外します 3 保守 点検 注意 ガソリンは高揮発性の燃料です ポンプの洗浄などには絶対に使用しない でください 引火 爆発の恐れがあります 点検とその対策 予備部品リスト 4 主要諸元 仕様 NLGI No グ リ ー ス ち ょ う 度 の 適 用 範 囲 は 目 安 と な り ま す グリースの性状によっては適用範囲でも使用できない場合があります ポンプ性能 別売アクセサリー 5 保証規定 本製品は 厳重な検査に合格した後 皆様のお手元にお届けしております 取扱説明書 本体注意ラベルなどの注意書に従って正...

Page 2: ...ugh indication The range may be different depending on property of the grease Pump Specifications Optional Accessories 5 Limited Warranty If an abnormality occurs during normal operation in accordance with the operating instructions and other operating cautions within the warranty period 12 months after date of purchase that can be attributed to a manufacturing defect the defective parts of this p...

Page 3: ...注油嘴 连接固定好 2 松开弹簧把手 踩踏踏板 进行注油 3 注油结束后 用脚将脚踏板上抬 将油管内残 留的压力排出 4 结束注油时 捏住弹簧把手 移除连接中的注 油嘴 3 维护保养 定期检查 注意 汽油属于高挥发性燃料 严禁用于油脂泵的清洗 如果使用 会有引发火灾 以及爆炸的危险 定期检查以及对应措施 配件 4 主要规格 规格 NLGI No 油脂的粘度 代表可使用材料的范围基准 但 根据油脂的性质不同 即便是可用材料范围基准以内的油脂 也有不可使用的情况 泵的性能 备选配件 5 保证规定 送到您手中的产品均为经过严格检查的合格产品 虽按照使用说明书 本体注意标签等 注意事项进行正常使用 但在保修期内因本公司的责任发生故障时 从发货日起 12 个 月以内的保修期内 本公司将无偿对该产品进行返修 修理 或者更换新品 但是 所发生的从属性损失的补偿以及发生下列故障时不在保修之列 1 保修期 ...

Reviews: