Yale Fire Safe
User Manual
Treasuring
your freedom
An ASSA ABLOY Group brand
For Models:
Please keep manual safe
for future reference.
English
YFM/310/FG2
YFM/420/FG2
YFM/520/FG2
YDM/420/FG3
9V
Installing
the batteries
Open the safe.
Remove the battery cover located on
the rear of the door.
Place the batteries according to the
illustration at the back of the battery
compartment. Once the batteries
are installed, close the battery
compartment.
Before using your Yale safe you must insert
batteries. The safe requires 4 “AA” (1.5V R06) –
which are included.
1
2
3
1
2
3
Safe
overview
Default user
passcode registration
The lock allows for two user codes. To set an
additional passcode follow the procedure above
but press after pressing the
programming button.
If the batteries of the safe run out you can use a 9V battery to power up the lock.
Opening
the safe
Closing
the safe
Faceplate
Knob
Touch panel
Low battery indicator
9V battery connector
Speaker
Programming button
Battery compartment
Locking bolts
1
2
3
4
5
6
7
8
9
Opening the safe with
emergency battery
Sound on / off
Additional user
passcode registration
Time lock
period setting
1
Open the safe find the programming button
3
Insert code
4
Press the programming button
press
press
2
Wake the safe up by pressig the
programming button
2
ENTER
A one-time passcode ensures the integrity of
your code no matter who is in the room when
you access your safe.
To set a one-time passcode follow the procedure
above but press after pressing the
programming button.
One-time
passcode registration
3
ENTER
Silent input let's you temporarily turn off the feedback signals from the safe to increase your privacy.
If the wrong code is entered more than
5 times the safe will lock down for a
period of time that can be set to
3-9 minutes.
To prevent any access to the safe you
can manually lock the safe down for
01-48 hours.
4
1
2
Press
3
ENTER
press
Lock-down
period
1
3 9
Press
-
Cover
backover
p2
p1
p6
p5
p4
p3
1
Touch the panel
2
Turn the knob
2
Insert code
3
Turn the knob and open the safe
1
Close door
1
2
3
4
5
ENTER
6
7
8
9
0
press code
1
2
3
4
5
ENTER
6
7
8
9
0
Scramble code
press
press
A scramble number input enables personal codes to be hidden within longer sequences of numbers.
The scramble number can be used either before or after the user code.
1
Touch the touch panel
2
Scramble number
code
or
scramble number
1
2
3
4
5
ENTER
6
7
8
9
0
01 48
2
3
-
Press
Press
code
ENTER
press
Touch the panel
1
2
3
4
5
ENTER
6
7
8
9
0
1
2
3
4
5
ENTER
6
7
8
9
0
1
2
3
4
5
ENTER
6
7
8
9
0
1
1
2
3
4
5
ENTER
6
7
8
9
0
1
2
3
4
5
ENTER
6
7
8
9
0
Open the safe and press programming button
Silent opening
The audio feedback can also be completely turned off.
1
Touch the panel
press
2
5
ENTER
Press
press
1
2
3
4
5
ENTER
6
7
8
9
0
3
Insert code
2
ENTER
Press
two times
This product is heavy, be careful when handling
it since it can cause injury.
!
The safe is delivered with the door in the open
position. If you accidentally close the door before
installing the batteries follow instructions to open
the safe with an emergency battery. If you
accidentally close the safe before setting a
personal passcode the
pre-programmed
factory code is 1 2 3 4.
!
Note, during the lock-down period the safe panel will shut
down completely, no-one will be able to operate the safe
.
!
Note, when the time lock sets in the touch pad will not
respond until the until the lock down period has passed
.
!
!
Please note that your user code does not have to
be reset when new batteries are installed.
When batteries need changing there will be a
warning sound when you open the safe.
When batteries need changing there will be a
warning sound when you open the safe.
The passcode can be set between 4-12 digits
Keep a 9V battery available to be able to open
the safe in case the batteries run out
unexpectedly
.
1
Connect the battery to the 9V battery port
on the bottom left of the faceplate
3
I
nsert code
4
5
Turn the knob and open the safe
Replace batteries as instructed under
"Installing the batteries"
2
Touch the panel
The one-time passcode will expire once used.
!
When closing the door ensure the
bolts are fully retracted and that the
knob can’t be turned to the open position.
Open the safe and press programming button
9V
For any inquiries visit
www.yalelock.com
1
2
3
4
5
ENTER
6
7
8
9
0
7
9
8
NB: Pre-set factory code 1,2,3,4
ENTER
press
ENTER
press
Fitting guide
To reduce the risk of theft it is essential
that your safe is securely fixed. Please use
the included bolts and secure to a solid
concrete floor.
For maximum performance and correct
installation a professional locksmith must
install the safe.
For any inquiries visit www.yalelock.com
That the safe is placed horizontally.
To keep the safe in a dry environment
to prevent corrosion to the safe and
locking mechanism.
To use the
fi
xing bolts provided for
installation on a solid concrete
fl
oor.
•
•
•
Before fixing the safe please ensure
:
2
4
1
3
Mark the position of the safe through
fi xing holes.
Remove the safe and drill the holes as
marked.
1
2
Reposition the safe over the holes.
Drop the bolts through the safe and into
the drilled holes. You may have to use a
hammer to drive the bolts down.
Tighten the fi xing bolts fi rmly and ensure
there is no movement of the safe.
3
4
The performance of the safe is dependant on the
quality of the installation and the quality of material
to which the safe is fi xed.
This product is heavy. Incorrect installation may
result in injury.
!
An ASSA ABLOY Group brand
3
4
Summary of Contents for YSB/200/EB1