Yale YFL01-BLK-PKG1.0.2 Quick Start Manual Download Page 12

About the Guide

Operating with Yale View app

Installing

Camera

Step 2

Scan the following QR code or search Yale View app in Google Play or App
Store to download and install the Yale View app.

Step 5

Step 4

Connect your smart phone to your Wi-Fi network, and make sure that
your smartphone is connected to Wi-Fi network with 2.4 GHz band, then 
follow the in app instructions to complete finishing setting up the camera. 

Run the Yale View app, and then register an account for first use.

Step 3

Wait for the camera to finish the booting cycle, and then the camera indicator 
flashes with a green light. 

 Note

If your Wi-Fi network changes or the indicator status changes, 
reset the camera and re-do the setup from step 5 to add it again.  

If you have more than one camera, do step 5 to add them one
by one.

Disclaimer

Using the hook provided, hook one end of the hook into the hole on the 
mounting box, and the other end to the edge of the camera, so you 
can use both hands to complete the installation.

Step 7 

Adjust the light and lens angle, and keep the PIR detector parallel 
to the ground to ensure optimal detection.

Step 1

Power on the camera. 

Step 3

Put away all the wires, attach the camera to the mounting box, and 
fix the camera with mounting screws and apply the screw cover to 
the mounting box. 

Step 4

Step 1

If there is no holes in the wall, insert the drilling template where 
you want the floodlight camera to be installed. Using the drill 
template as a guide drill the two parallel holes on the wall, add the 
wall plugs and move to the next step.  

Note

If you have installed the app, update it to the latest version.

This guide is for informational purpose only. Working with electricity 
can be dangerous unless proper safety precautions are taken. If you 
are not comfortable or are inexperienced with the processes and tools 
described in this manual, we strongly suggest that you hire a licensed 
electrician.

All the design and software here are subject to change without prior 
written notice.

All trademarks and registered trademarks mentioned are the prop-
erties of their respective owners.

Please visit our website or contact your local service engineer for more 
information.

If there is any uncertainty or controversy, please refer to our final 
explanation.

-

-

-

-

Be sure to disconnect the power at the fuse or circuit breaker before 
installation.

Always follow code standards when installing wired connection.

Verify that the supply voltage is correct. Connect fixture to a 
100–240VAC 50/60 Hz power source.

We strongly suggest that you hire a licensed electrician to install the 
camera.

Risk of fire

Do not install the camera near combustible or flammable surfaces.

Note 

Do not connect this light fixture to a dimmer switch or timer.

Make sure that the mounting surface is strong enough to hold at 
least three times of the device weight.

-

-

-
-

-
-

Risk of electrical shock

WARNING

Step 8 

For permanently connected equipment, a readily accessible 
disconnect device shall be incorporated external to the equipment.

-

For pluggable equipment type B or permanently connected 
equipment, the maximum rating of an overcurrent protective 
device to be provided external to the equipment is 20A.

-

Step 2

Turn the adjusting knobs to loosen the lights, and adjust the light 
angles to give space to the mounting screw. Loosen the mounting 
screw to open the mounting box, and then loosen the screw on the 
ground terminal to remove the ground wires.

Attach the mounting box to the wall with the self-tapping screws, 
making sure the UP arrow is in the correct position. 

Step 5

L

N

Connect the two removed yellow and green striped wire (ground 
wires) to the ground terminal again, tighten the screw on the ground 
terminal, and then put back the terminal board with the insulating 
gasket in the mounting box.

Step 6 

Take out the terminal block from the mounting box. Connect the blue 
wires (neutral wires) to the terminals N, and the brown wires (live 
wires) to terminals L, and then the yellow and green strip wire to 
ground terminal on the board.

Part of ASSA ABLOY

Summary of Contents for YFL01-BLK-PKG1.0.2

Page 1: ...YFL01 BLK PKG1 0 2 Version 1 0 2 Floodlight Camera Quick Start Guide...

Page 2: ...QSG 1 Floodlight Camera 1 Mounting Box 1 Mounting Screw 1 Hook 1 Fixing Pack 1 Note In the fixing pack there are 3 wall plugs and 3 self tapping screws Identifying the parts Drilling Template 1...

Page 3: ...Assembly Mounting Screws Mounting Box Camera Ground Terminal Adjusting Knob Bracket Screw Terminal Board Ground Terminal Terminal Board Cable Entry Mounting Hole Insulating Gasket...

Page 4: ...ion 10 Meters 33 feet 3 Meters 10 feet When mounted at 3 m 10 feet off the ground with the PIR lens parallel to the ground the motion detector is optimized to detect human sized objects at up to 10 m...

Page 5: ...Introduction Camera Floodlight Floodlight Built in Mic Lens LED Indicator PIR Detector...

Page 6: ...tus Green light flashing Green light on Red light flashing Green and red light flashing alternately Powered off LED turned off Rebooting after reset Booting Device malfunction Waiting for network Oper...

Page 7: ...ot install the camera near combustible or flammable surfaces Note Do not connect this light fixture to a dimmer switch or timer Make sure that the mounting surface is strong enough to hold at least th...

Page 8: ...te as a guide drill the two parallel holes on the wall add the wall plugs and move to the next step Step 2 Turn the adjusting knobs to loosen the lights and adjust the light angles to give space to th...

Page 9: ...e hole on the mounting box and the other end to the edge of the camera so you can use both hands to complete the installation Step 3 Step 4 Attach the mounting box to the wall with the self tapping sc...

Page 10: ...ground terminal and then put back the terminal board with the insulating gasket in the mounting box Step 6 Take out the terminal block from the mounting box Connect the blue wires neutral wires to the...

Page 11: ...gle and keep the PIR detector parallel to the ground to ensure optimal detection Put away all the wires attach the camera to the mounting box and fix the camera with mounting screws and apply the scre...

Page 12: ...e or search Yale View app in Google Play or App Store to download and install the Yale View app Run the Yale View app and then register an account for first use Step 3 Step 1 Power on the camera Note...

Page 13: ...app instructions to complete finishing setting up the camera Wait for the camera to finish the booting cycle and then the camera indicator flashes with a green light Note If your Wi Fi network changes...

Page 14: ...ed in this manual we strongly suggest that you hire a licensed electrician All the design and software here are subject to change without prior written notice All trademarks and registered trademarks...

Reviews: