6.
Disconnect the negative terminal of the battery.
7.
Move the manual hydraulic levers forward and backward
to relieve the system hydraulic pressure.
8.
Disconnect the Quick-Disconnect hose connectors.
Connecting Attachment Hydraulic Quick-
Disconnect Hoses
NOTE: Step 1
is to be used for lift trucks
equipped with manual hydraulics.
1.
Connect the Quick-Disconnect hose connectors.
2.
Connect the negative terminal of the battery.
3.
Turn the key switch or keyless switch to the
ON
position
and start the engine.
4.
Move the manual hydraulic levers forward and back-
ward, and check the hydraulic system for leaks.
NOTE: Step 5
is to be used for lift trucks
equipped with electro-hydraulics.
5.
Connect the Quick-Disconnect hose connectors.
6.
Connect the negative terminal of the battery.
7.
Turn the key switch or keyless switch to the
ON
position
and start the engine.
8.
Move the mini-levers forward and backward, and check
the hydraulic system for leaks.
Stopping
Stop the lift truck as gradually as possible. Hard braking
and wheel sliding can cause the forklift to tip or the load to
fall off of the forks and damage the load or hurt someone.
Operating Procedures