Use provided hex wrench to turn valves. 

NEVER force valves out of closer. NEVER 

completely close backcheck valve. 

Door must be open to adjust spring 

closing power. Refer to chart. 

Do not use 

a power drill. Warranty will be void.

• 

“DA” suffix (Delayed Action) is an optional feature.

 

•  For special applications, a separate door and frame 

preparation template is packed with these instructions. Use 

this instruction sheet for installation sequence and closer 

adjustments only. 

•  Doors should be hung on ball bearing or anti-friction hinges.

Mounting Hardware

Door or Frame

Drill

Closer, H/O Shoe or Optional PA Bracket:  

1/4-14 x 1-1/2 Oval Flat Head Mach. Screw

Wood

3/16" (4.76mm)

Closer, H/O Shoe or Optional PA Bracket: 

 

1/4-20 x 3/4 Oval Flat Head Mach. Screw

Metal

Drill #7 (.201 dia. or 5.10mm)

 

Tap 1/4-20

H/O Shoe to Optional PA Bracket: 

1/4-20 x 1/2 Oval Flat Head Mach. Screw

Closer: 

Sleeve Nut and Bolt (SNB)

 

(optional)

Hollow Metal

9/32" (7.00mm) thru

 

3/8" (9.50mm) door face opposite to closer

Aluminum or Wood

3/8" (9.50mm) thru

Closer: 

Thru Bolt and Grommet Nut (TBGN)

 

(optional)

All

9/32" (7.00mm) thru

 

3/8" (9.50mm) dia. x 3/8" (9.500mm) deep, 

door face opposite to closer

•  A separate door stop is recommended.

•  Always consult door/frame manufacturer for fastener compatibility.

•  Door and frame must be properly reinforced.

• 

Adjust closing time speed between 3 and 7 seconds from 90° to 0°. 

Greater closing times may be required for elderly or handicapped.

•  These door closers should NOT be installed on exposed side 

(weather side) of exterior doors.

• 

Dimensions are given in inches (millimeters).

ATTENTION:

 

An incorrectly installed or improperly adjusted door closer can 

cause property damage or personal injury. These installation 

instructions should be followed to avoid the possibility of 

misapplication or misadjustment.

Closer Adjustments 

Do not over tighten 

cap or cover screws.

Pinion Cap and Cover 

Latch

Backcheck

Sweep

Architectural (“A”) covers 

cannot be used on parallel 

mounted closers with doors 

swinging over 120°.

Regular Arm

Top Jamb Mount

Parallel Arm

 

Optional

Delayed Action

Before You Begin 