background image

10

An ASSA ABLOY Group brand

P/N AYRD210-INST-FUL Rev B

Lockout Mode

: This feature is enabled by the Master code. When enabled, it restricts all 

user PIN code access. When attempting to enter a code while the unit is in Lockout, the 
Status Indicator flashes RED and BLUE; the keypad flashes as well.

Low Battery

: When battery power is low, the Status Indicator flashes RED. If battery 

power is completely lost, use the key override. 

Master PIN Code

: The Master code is used for programming and for feature settings. 

NOTE: The default Master Pin Code must be changed prior to programming the 

lock. 

The Master code will also operate the lock.

Privacy Mode

: This button located under the thumb turn on the inside escutcheon, ac-

tivates and deactivates the keypad and is indicated by a BLUE flash every ten (10) sec-
onds. It is also overridden by mechanically operating the thumb turn or key.

Auto Re-lock Time

: After successful code entry and the unit unlocks, it will automatically 

re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to 
thirty (30) seconds.

    

One Touch Re-Lock: 

When the bolt is retracted, activating the keypad will extend the bolt   

    (during Auto Re-Lock duration or when Auto Re-Lock is disabled). 

Shutdown Time

: The unit will shutdown for a default of sixty (60) seconds and not allow 

operation after the wrong code entry limit has been met. When the unit is in Shutdown, 
the Status Indicator flashes RED and BLUE; the keypad flashes as well.

Audio Mode

: Choosing 

Disable (3)

 in Audio mode shuts off the code confirmation tone 

playback for use in quiet areas. Audio mode is enabled or disabled through feature pro-
gramming by the Master code.

Status LED

: Located on inside escutcheon. 

User PIN Code

: The User code operates the lock. Maximum number of user codes is 

250 with Network Module; without Network Module, maximum is 25 user codes.

Wrong Code Entry Limit

: After a specified number of unsuccessful attempts at entering 

a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is 
adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no 
RF network enabled - default is 5; 10 with RF network enabled). 

    

Definitions

Settings

Factory Defaults

Master Code

12345678

Auto Re-lock

Enabled

Audio

Enabled

Re-lock Time

*30 Seconds

Wrong Code Entry Limit

*5 Times

Shutdown Time

*60 Seconds

    Factory Defaults

*Adjustable with Network Module

Summary of Contents for Real Living YRDZB

Page 1: ...lable on our website in printed Spanish and French Go to www yalerealliving com Click Product Information Documentation and then Installation Instructions Este documento est disponible en espa ol en n...

Page 2: ...U4A YRHCPZB0 Zigbee Model s YRDZW YRDZB This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed t...

Page 3: ...lf correctly To reset the lock to factory default see the following The following procedure clears the automatic handing of the lock and returns the lock to programming default deleting all user codes...

Page 4: ...erf rence qui peut causer l op ration peu d sir e For the U4A YRHCPZB0 and 6982A YRHCPZB0 the following statement applies This equipment complies with FCC IC radiation exposure limits set forth for an...

Page 5: ...Instructions Door Marker Outside Escutcheon Bolt Strike Plate Screw Pack Keys Included in the box COMPONENTS AND TOOLS Inside Escutcheon Inside Mounting Plate Battery Cover 4 AA Alkaline Batteries IN...

Page 6: ...om of battery cover 3 Remove the inside mounting plate with gasket from the back door side of the inside escutcheon Battery Cover Inside Escutcheon C The outside escutcheon with gasket remains assembl...

Page 7: ...the outside escutcheon route the cable through 2 1 8 diameter hole Figure 3A INSTALL LOCK Figure 4A Figure 3B Figure 3A 4 Holding the outside escutcheon flush to the door position the inside mounting...

Page 8: ...on PCB as in Fig 6A 6B Figure 6B Figure 7A Figure 6A CAUTION Use care when assembling to ensure that the cable lies against the back recessed area of the inside escutcheon Fig 6A Position and bend cab...

Page 9: ...acy Mode Button Menu and Icons Used in This Guide Cylinder Click the indicated number Enter Master PIN code 4 8 digits in length Factory default 12345678 Press the Star key on the keypad to Enter or A...

Page 10: ...lt is retracted activating the keypad will extend the bolt during Auto Re Lock duration or when Auto Re Lock is disabled Shutdown Time The unit will shutdown for a default of sixty 60 seconds and not...

Page 11: ...number to be registered 1 25 followed by the key 4 Enter a 4 8 digit PIN code for the User number followed by the key Set Up User Codes Note When registering User codes the code must be entered with i...

Page 12: ...tting M M User PIN Deletion Audio Mode All Code Lock out Network Module Setting Enable Enable Register Disable Delete Disable User Number UN 1 25 without network module 1 250 with network module 1 2 U...

Page 13: ...perly aligned and door is free swinging b Check hinges They should not be loose or have excessive wear on knuckles Bolt will not deadlock a Check for sufficient clearance of the bolt within the strike...

Page 14: ...enabled Disable Auto Re lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN codes will not register PIN codes must consist of 4 to 8 digits to regis...

Page 15: ...T The batteries must be removed prior to removing and or inserting the network module Remove batteries Remove and or insert network module Reinstall batteries Installing the Network Module Use feature...

Page 16: ...after plastic guide is removed F Remove cylinder by pulling towards the door side of escutcheon Before installing cylinder please be sure you have correct length tailpiece 2 Install new cylinder A Re...

Page 17: ...Network Module Up to 25 Users Location Door Number User User Name User PIN Code User Type User Name User PIN Code Master User 13 User 1 User 14 User 2 User 15 User 3 User 16 User 4 User 17 User 5 Use...

Page 18: ...r ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User...

Page 19: ...ompany Yale is a registered trademark of Yale Security Inc an ASSA ABLOY Group company All rights reserved Yale Real Living is a trademark of Yale Security Inc an ASSA ABLOY Group company Copyright 20...

Reviews: