Lockout Mode
: This feature is enabled by the Master code. When enabled, it restricts all
user PIN code access. When attempting to enter a code while the unit is in Lockout, the
Status Indicator flashes RED and BLUE; the keypad flashes as well.
Low Battery
: When battery power is low, the Status Indicator flashes RED. If battery
power is completely lost, use the key override.
Master PIN Code
: The Master code is used for programming and for feature settings.
NOTE: The default Master Pin Code must be changed prior to programming the
lock.
The Master code will also operate the lock.
Privacy Mode
: This button located under the thumb turn on the inside escutcheon, ac-
tivates and deactivates the keypad and is indicated by a BLUE flash every ten (10) sec-
onds. It is also overridden by mechanically operating the thumb turn or key.
Auto Re-lock Time
: After successful code entry and the unit unlocks, it will automatically
re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to
thirty (30) seconds.
One Touch Re-Lock:
When the bolt is retracted, activating the keypad will extend the bolt
(during Auto Re-Lock duration or when Auto Re-Lock is disabled).
Shutdown Time
: The unit will shutdown for a default of sixty (60) seconds and not allow
operation after the wrong code entry limit has been met. When the unit is in Shutdown,
the Status Indicator flashes RED and BLUE; the keypad flashes as well.
Audio Mode
: Choosing
Disable (3)
in Audio mode shuts off the code confirmation tone
playback for use in quiet areas. Audio mode is enabled or disabled through feature pro-
gramming by the Master code.
Status LED
: Located on inside escutcheon.
User PIN Code
: The User code operates the lock. Maximum number of user codes is
250 with Network Module; without Network Module, maximum is 25 user codes.
Wrong Code Entry Limit
: After a specified number of unsuccessful attempts at entering
a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is
adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no
RF network enabled - default is 5; 10 with RF network enabled).
Definitions
Settings
Factory Defaults
Master Code
12345678
Auto Re-lock
Enabled
Audio
Enabled
Re-lock Time
*30 Seconds
Wrong Code Entry Limit
*5 Times
Shutdown Time
*60 Seconds
Factory Defaults
*Adjustable with Network Module