Yale PINTR634SS Use, Care And Installation Manual Download Page 4

4

Electrical & Installation requirements

IMPORTANT

Observe all governing codes and ordinances.

It is the customer’s responsibility:

• 

To contact a qualified electrical installer.

• 

To assure that the electrical installation is adequate and in 

conformance with National Electrical Code, ANSI/NFPA 70 — 

latest edition*, or CSA Standards C22.1-94, Canadian Electrical 

Code, Part 1 and C22.2 No.0-M91-latest edition** and all local 

codes and ordinances.

• 

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that the 

ground path is adequate.

• 

Do not ground to a gas pipe.

• 

Check with a qualified electrician if you are not sure range hood 

is properly grounded.

• 

Do not have a fuse in the neutral or ground circuit.

IMPORTANT

• 

Save Installation Instructions for electrical inspector’s use.

• 

The range hood must be connected with copper wire only.

• 

The range hood should be connected directly to the fused 

disconnect (Or circuit breaker) box through metal electrical 

conduit.

• 

Wire sizes must conform to the requirements of the National 

Electrical Code ANSI/NFPA 70 — latest edition*,or CSA 

Standards C22.1-94, Canadian Electrical Code Part 1 and 

C22.2 No. 0-M91 - latest edition** and all local codes and 

ordinances.

• 

A U.L.- or C.S.A.-listed conduit connector must be provided at 

each end of the power supply conduit (at the range hood and at 

the junction box).

Copies of the standards listed may be obtained from:

* National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269

** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575

BEFORE INSTALLING THE HOOD

For the most efficient air flow exhaust, use a straight run or as 

few elbows as possible.

CAUTION: Vent unit to outside of building, only. 

2  At least two people are necessary for installation. 

3  Fittings material is provided to secure the hood to most types 

of walls/ceilings, consult a Qualified Installer, check if they 

perfectly fit with your cabinet/wall. 

Do not use flex ducting.

5  COLD WEATHER installations should have an additional 

backdraft damper installed to minimize backward cold air flow 

and a nonmetallic thermal break to minimize conduction of 

outside temperatures as part of the ductwork. The damper 

should be on the cold air side of the thermal break. The break 

should be as close as possible to where the ducting enters the 

heated portion of the house. 

6  Make up air: Local building codes may require the use of 

Make-Up Air Systems when using Ducted Ventilation Systems 

greater than specified CFM of air movement. The specified 

CFM varies from locale to locale. Consult your HVAC 

professional for specific requirements in your area

Product Dimensions

A

G

E

F

I

D

C

B

H

J

J

Models

PINSV628SS PINSV134SS PINTR628SS PINTR634SS PINTR146SS

A

28½” (71.9 c m) 34½” (87.6 cm) 28½” (71.9 c m) 34½” (87 .6 cm) 46½” (117.8 cm)

B

15 

3

4

” (39.9 cm)

18” (45.7 cm)

C

5

7

16

” (13.8 cm)

D

6

1

2

” (16.4 cm)

E

22" (56 cm)

27

9

16

” (70 cm)

22" (56 cm)

27

9

16

” (70 cm)

F

12 

3

8

” (31.4 cm)

G

24" 

5

/

16

(61.8 cm)

29

13

16

” (75.7 cm)

24" 

5

/

16

(61.8 cm)

29

13

16

” (75.7 cm)

H

10

1

16

” (25.6 cm)

I

10” (25.4 cm)

J

3

4

” (1.9 cm)

Summary of Contents for PINTR634SS

Page 1: ...n et d installation Gu a de instalaci n uso y mantenimiento READ AND SAVE THESE INSTRUCTIONS LISEZ CES INSTRUCTIONS ET CONSERVEZ LES LEA Y GUARDE ESTAS INSTRUCCIONES LIB0184495A Printed in Mexico 07 2...

Page 2: ...for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring this appliance Requirement 120 V AC 6...

Page 3: ...ood only in conjunction with ranges or range tops rated at maximum 90 KBTU s WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cau...

Page 4: ...tional Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 BEFORE INSTALLING THE HOOD 1 For the most eff...

Page 5: ...gsaw or keyhole saw Flat blade screwdriver Metal snips Phillips screwdriver Parts needed Home power supply cable 12 7 mm UL listed or CSA approved strain relief 3 UL listed wire connectors 1 wall or r...

Page 6: ...an acceptable level of ventilating performance This hood is intended for household use PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC APPLICATION Check your ceiling height and hood height before se...

Page 7: ...uld use the spacers Install Range Hood into Hood Cabinet The range hood attaches to the hood cabinet using four mounting screws and washers NOTE Hood cabinet must be capable of supporting Prepare Rang...

Page 8: ...RICAL SHOCK HAZARD IWARNING DISCONNECT POWER BEFORE SERVICING REPLACE ALL PARTS AND PANELS BEFORE OPERATING FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK 1 Disconnect power 2 Locate termina...

Page 9: ...o turn the range hood lights On 2 Turn the light switch to the OFF position to turn the range hood lights Off Operating the blower 1 Turn the blower switch at 1 to turn the range hood on 2 Turn the bl...

Page 10: ...e trays as needed in dishwasher or hot detergent solution to clean 5 Replace grease drip tray 6 Reinstall filters grasp filter handles and place front edge of filter into the hood 7 Push up on the bac...

Page 11: ...urchaser for products purchased for ordinary residential use in North America Including the United States Guam Puerto Rico US Virgin Islands Canada This warranty is non transferable and applies only t...

Page 12: ...rder les fils de cet appareil Exigence 120 V c a 60 Hz circuit de d rivation de 15 V c a 20 Hz de 15 ou 20 A Fran ais Avis de s curit important 13 Exigences lectriques et D Installation 14 Dimensions...

Page 13: ...NSV134SS et PINTR146SS utilisez cette hotte uniquement avec des cuisini res ou des dessus de cuisini re d une capacit maximale de 90 KBTU I AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE GRAISSE...

Page 14: ...Association Batterymarch Park Quincy Massachusetts 02269 La CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 AVANT D INSTALLER LA HOTTE 1 Pour assurer la ventilation la plus...

Page 15: ...hillips Pi ces n cessaires C ble d alimentation domestique Serre c ble de 1 2 12 7 mm homologation UL ou CSA 3 connecteurs de fils homologu s UL Bouche de d charge murale ou travers le toit corres pon...

Page 16: ...efficacit de la capture de la fum e et de l humidit et la performance de ventilation S IL VOUS PLA T LIRE L INSTALLATION POUR UNE INSTALLATION SP CIFIQUE Avant de choisir la hotte v rifiez la hauteur...

Page 17: ...un foret de 3 mm A B C D E Mur Axe central DIMENSIONS TROU DE MONTAGE Mod le DIM A DIM B DIM C DIM D DIM E PINTR146SS 2 5 cm 101 16 25 6 cm 1415 16 38 cm 2913 16 75 8 cm 1 4 6mm PINTR634SS 1 8 3mm PIN...

Page 18: ...s C Connecteurs de fils homologation UL D Conducteurs verts ou nus ou vert jaune de liaison la terre E C ble d alimentation lectrique du domicile F Serre c ble homologation UL ou CSA ter l opercule ar...

Page 19: ...tilateur Pour faire fonctionner les lampes 1 Tournez le commutateur d clairage sur la position ON pour allumer les lumi res 2 Placer le commutateur d clairage la position OFF arr t pour teindre les lu...

Page 20: ...nstaller le plateau d gouttement graisse 6 R installer les filtres saisir les poign es du filtre et placer le rebord avant du filtre dans la hotte 7 Pour bien fixer le filtre pousser vers le haut sur...

Page 21: ...ERT Cette garantie s tend l acheteur original de produits achet s pour un usage domestique habituel en Am rique du Nord Y compris Etats Unis Guam Porto Rico les Iles virgin Am ricaines le Canada Cette...

Page 22: ...eado de este aparato desactive el circuito de energ a el ctrica en el panel de servicio y desbloquee el panel Requisito Circuito auxiliar de 120 V AC 60 Hz 15 20 A Espa ol Aviso de Seguridad Important...

Page 23: ...combinaci n con cocinas o encimeras con una capacidad m xima de 78 KBTU Para los modelos PINSV134SS y PINTR146SS utilice esta campana s lo en combinaci n con cocinas o encimeras con una capacidad m xi...

Page 24: ...Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 ANTES DE INSTALAR LA CAMPANA 1 Para obtener una circulaci n del fluj...

Page 25: ...llador Phillips Caladora o sierra Tijeras para corte de metal Partes necesarias Cable de alimentaci n el ctrica Conducto de cable de 12 7 mm aprobado por UL o CSA 3 conectores de cables aprobados por...

Page 26: ...pulgada 2 54 cm superior a 36 91 4 cm disminuir la eficiencia en la captura de humo y humedad as como el desempe o de ventilaci n Para uso electrodom stico POR FAVOR LEA EL MANUAL DE INSTALACI N PARA...

Page 27: ...entro DIMENSIONES DE LOS ORIFICIOS DE INSTALACI N Modelo DIM A DIM B DIM C DIM D DIM E PINTR146SS 2 5 cm 101 16 25 6 cm 1415 16 38 cm 2913 16 75 8 cm 1 4 6mm PINTR634SS 1 8 3mm PINSV134SS PINTR628SS 1...

Page 28: ...a lista de UL y conecte los cables negros B juntos Use conectores de cables que est n en la lista de UL y conecte los cables blancos A juntos ADVERTENCIA PELIGRO DE CHOQUE EL CTRICO ADVERTENCIA CONECT...

Page 29: ...trol a la posici n ON para encender las luces 2 Gire el control a la posici n OFF para apagar las luces Funcionamiento del motor 1 Gire el control a la posici n 1 para encender la campana 2 Gire el co...

Page 30: ...avaplatos o con soluci n jabonosa caliente 5 Vuelva a colocar las graseras 6 Reinstale los filtros A A Filtro de grasa Reemplazo de las l mparas LED Apague la campana de cocina y espere a que la l mpa...

Page 31: ...sta garant a se extiende al comprador original de productos adquiridos para uso residencial en Norte Am rica incluyendo Estados Unidos Guam Puerto Rico Islas V rgenes de EU y Canad Esta garant a no es...

Page 32: ...32...

Reviews: