Yale HSA6200 Installation, Programming, Operating Download Page 12

12

Setting or changing your keypad PIN 
code

1

 Press the Panic button A, enter “0000” (default 

code).  The LED will flash continuously to indicate 
keypad test (programming) mode.

2

 Press panic button B.

3

 Enter new 4-digit PIN code.

4

 Press Arm button to confirm.

5

 Press disarm twice to quit the changing code 

process. Or wait for 5 minutes for the keypad to 
quit test mode automatically.

• If the code change is successful the LED will flash 

twice. If there is an error the LED will flash 4 times.

• If the PIN code doesn’t change, repeat the above 

procedure quickly without gaps.

• Write your code in the space provided below so 

you don’t forget it

• If you wish to change the PIN code again, you will 

need to enter your new changed PIN code instead 
of “0000” as described in step 1.

• If there are 4 attempts to guess the code by 

entering random 4 digit numbers, the keypad 
will lock out for one minute after the fourth failed 
attempt.

My PIN code

Arming the system

To arm the system press the “arm” button on the
keypad/keyfob. The siren will beep and flash
once. You can now leave your premises.

• A keypad will arm the system with a 20 second 

exit period to leave the premises. Any detectors 
activated during this time will be ignored by the 
system.  The system can be armed when inside 
the protected area of your premises.

• A keyfob will arm the system instantly without 

a 20 second exit delay.  Any detector activated 
afterwards will trigger an instant alarm.  The 
system should be armed when outside the 
protected area of your premises.

• The system does not have an audible countdown 

during the exit period.

• System tampers will be active during the exit 

period.

Disarming the system

Keypad:

 

Press disarm followed by your PIN code.

The siren will beep and flash twice.

• If the system has been armed with a keypad there 

will be a 20 second entry period started when the 
first detector is activated (usually a window/door 
contact on the main point of entry). During this 
entry period all detectors will be ignored. 

• The siren will beep once when the first detector is 

triggered.

• The system can be disarmed from inside the 

protected area of your premises.

• If the system is not disarmed before the entry 

period expires, the alarm will be activated.

• The system does not have an audible countdown 

during the entry period.

• System tampers will be active during the entry 

period.

Keyfob:

 

Press “disarm”, the siren will beep and flash 

twice.

• If the system has been armed with a keyfob there 

will be no 20 second entry period and any detector 
activation will give an instant alarm.

• The system should be disarmed from outside the 

protected area of your premises.

 

Stopping the alarm

Keypad:

 

Press disarm followed by your PIN code.  

Keyfob:

 

Press disarm.

The siren will be silenced and then beep and flash 
twice.

Using the system

Arm and disarm the system and practice using it. Trigger the alarm by arming the system and 
opening protected doors/windows and walking past PIRs. Now’s the time to set our pin code 
and show the rest of the family how simple it is to use.

5

Summary of Contents for HSA6200

Page 1: ...Siren Based Alarm System Installation Programming Operating Keep this manual safe for reference and future maintenance Yale Consumer Helpline 01902 635998 ...

Page 2: ...ystem Each part of the system is tamper protected Any unauthorised tampering with the system will result in an alarm This feature can be turned off by the user when a battery change is required Entry Exit feature for System with remote keypad The system has a 20 second entry exit time This feature allows you time to leave the home when arming the system Upon entering the feature allows time to dis...

Page 3: ... based system 8 4 Mounting alarm devices 9 5 Using the system 12 Adding accessories 14 Changing the batteries 15 Specifications 17 Trouble shooting 18 Key points Back cover Accessories available HSA6020 Passive infra red PIR detector HSA6030 3 x Passive infra red PIR detectors HSA6010 Door window contact HSA6060 Remote control keyfob HSA6080 Remote keypad HSA3045 Help button HSA3070 Smoke detector...

Page 4: ... Install additional detectors if there are closed doors preventing smoke from reaching detectors Help button accessory The help button provides extra protection for you and your family When help is needed the button can activate your alarm immediately even when the system is disarmed Mount on bedroom wall or by the front door Not clearly visible to an intruder Easily accessible Out of reach of chi...

Page 5: ...es Ensure that the keypad is not visible from the outside of the premises Mount at chest height for ease of use Designed for indoor use only Extend the system Extend the system in the future to increase your security or as your needs change For example add extra PIR detectors in bedrooms and extra door window contacts Yale R Yale Door Window contacts Use one door window contact on a door that is u...

Page 6: ... lid 2 Square siren only remove the left hand cover not battery compartment 3 Move the programming switches to Master On switch 4 and Clear On switch 1 4 Switch the power switch to on and the 3 strobe LEDs will now flash side to side with one short beep 5 Move the Clear switch to the Off position PIR movement detectors 1 Pull out the plastic pull tab on the back of the PIR This will activate the b...

Page 7: ...et Extension terminals Learn Test button Learn Test button On Off switch Help button accessory Remove the cover by loosening the fixing screw and insert the 12V battery supplied as shown Please ensure you observe battery polarity Door window contacts 1 Remove the cover of each door window contact by loosening the fixing screw 2 Insert two AAA batteries into each detector as shown The indicator LED...

Page 8: ...signal then press disarm twice to quit test mode If device learning takes more than 3 minutes and the learn mode expires the learn button on the siren will need to be pressed again to add more devices repeat step 2 above 4 Press the Learn button on the siren to exit the learn mode the middle LED will flash once and there will be a single short beep to indicate that normal siren operation has been ...

Page 9: ...5 Press Arm with the Keypad Keyfob 6 If there are 5 short beeps when armed the tamper switch is NOT fully depressed and will need to be adjusted Unset the system by pressing Disarm on your keypad then 0000 or just Disarm on the keyfob Disable tamper as described above before adjusting the siren tamper switch If there is a gap between the wall and the tamper switch mechanism pack with a suitable sp...

Page 10: ...holes are for corner mounting 5 Drill holes into the wall using the knockout holes on the base as a template 6 Fit wall plugs and secure the PIR base with the screws provided 7 Fit the PIR back together and tighten bottom screw the PIR installation is complete The PIRs have a built in sleep timer to save battery power If there is no movement in front of the PIRs for 1 minute the PIRs will become r...

Page 11: ...es into the mounting surface using the holes in the knockouts on the base as template 4 Fit wall plugs if required and secure with the screws provided 5 Fit sensor back together and tighten screw 6 Test sensor by pressing the test button and opening and closing the door window The LED should light when the door window is opened Installation is complete Mounting the Help button 1 Break through the ...

Page 12: ...will trigger an instant alarm The system should be armed when outside the protected area of your premises The system does not have an audible countdown during the exit period System tampers will be active during the exit period Disarming the system Keypad Press disarm followed by your PIN code The siren will beep and flash twice If the system has been armed with a keypad there will be a 20 second ...

Page 13: ... smoke detector The smoke detector will indicate a fire by sounding its built in siren lighting the LED and activating the external siren and strobe Smoke detection When smoke is detected the device will activate for a minimum of 10 seconds with a two tone alarm and flashing LED for a local fire alarm The detector will also activate the external siren and strobe Pressing the test button when in an...

Page 14: ...ction Tamper protection will automatically rearm after 1 hour 7 Press Disarm twice to exit Keyfob 1 Press the Arm and Home buttons together and continuously for 5 seconds until the LED stops flashing to switch off the tamper while installing the new device The siren will beep in response 2 Press the Home and Emergency buttons together and continuously for 5 seconds until the LED stops flashing the...

Page 15: ...n section 4 2 Loosen the case screw and remove door window sensor from base to reveal battery 3 Using a screwdriver gently lever out the old battery 4 Insert new CR2032 coin cell with the side uppermost 5 Press battery into holder firmly with finger and thumb until a click is heard 6 Refit sensor on base and tighten bottom case screw Switch tamper protection back on Door window sensor case tamper ...

Page 16: ...050 HSA6060 HSA6080 HSA6090 HSA6091 HSA3045 HSA3070 Date 16 11 06 On behalf of ASSA ABLOY Ltd ASSA ABLOY Ltd School Street Willenhall West Midlands England WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 300 220 1 V2 1 1 2006 04 EN 301 489 1 V1 6 1 2004 12 EN 301 489 3 V 1 4 1 2002 08 EN 60 950 2001 A11 corrigendum 2004 ...

Page 17: ...ply 3V 2 x AAA alkaline cells 3 years typical domestic service life Smoke detector Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 6V 4 x AAA alkaline cells 3 years typical domestic service life Keyfob remote control Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 12V 23A MN21 alkaline miniature lighter battery 3 years typical domestic service life Keypa...

Page 18: ... into the Siren see either Programming the siren based system or Adding accessories sections PIR PIR does not respond to movement Previous movement has triggered the PIR sleep timer is preventing subsequent movement detection Arm system and vacate protected room for at least 1 5 minutes before testing PIR is slow to respond This is normal the PIR has sophisticated false alarm filtering that will f...

Page 19: ...19 ...

Page 20: ...to satisfying end user needs for security safety and convenience Yale UK School Street Willenhall West Midlands WV13 3PW Tel 44 0 1902 364647 Fax 44 0 1902 364692 www yale co uk Key points Stopping the alarm Keypad Press Disarm and enter your PIN code on the Keypad Keyfob Press Disarm If any of the devices beep or flash they have either been tampered with See trouble shooting page 18 or require a ...

Reviews: