background image

P/N YRL-LTSINSTL-FUL Rev D

1

®

®

Yale  Assure Lock  Lever Touchscreen

Installation and Programming Instructions

(YRL226)

#7 wood & #8-32

machine x 20mm

Combination screws 

x4

M4 x 22mm

Pan head machine

screws

x2

#8-32 x 5/16"

Machine screws

x2

Optional

Network Module

Battery Cover

Key

AA Alkaline

Batteries

Latch

Strike Plate

Interior Mounting Plate

Interior Lock

Battery Cover

Template

Keys

Levers

Cylinder

®

FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY

Before you begin

for step-by-step installation

instructions & to register

your product

DOWNLOAD

THE BILT APP

WARNING

This product can expose you to lead

 which is known to the state of 

California to cause cancer and birth defects or other reproductive harm. 
For more information go to www.P65warnings.ca.gov.

Summary of Contents for Assure Lock Lever Touchscreen YRL226

Page 1: ...trike Plate Interior Mounting Plate Interior Lock Battery Cover Template Keys Levers Cylinder FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY Before you begin for step by step installation instructions to register your product DOWNLOAD THE BILT APP WARNING This product can expose you to lead which is known to the state of California to cause...

Page 2: ...sel Pencil Tape Measure Level Tools necessary only for new doors or adjusting existing prep Template Tools Needed Standard Phillips Head Screwdriver Backset 2 3 8 60mm or 2 3 4 70mm 2 3 8 through bolt posts 2 3 4 through bolt posts Note Adjustment based on backset O optional default PULL ...

Page 3: ...P N YRL LTSINSTL FUL Rev D 3 Checking Measurements See Door Prep Template 2 3 8 or 2 3 4 60mm or 70mm Backset 2 1 8 54mm Diameter 1 3 8 or 1 3 4 35mm or 44 5mm Door Thickness ...

Page 4: ... left hand door Exterior Inswinging Door Interior Left Hand Reverse Right Hand Reverse Face a door swinging open toward you If it swings open to the right it is a right hand reverse door If it swings opens to the left it is a left hand reverse door Exterior Outswinging Door Interior Curve of latchbolt must contact strike plate first Frame Door Latchbolt Curve Strike Plate Exterior Interior Outside...

Page 5: ...cessary for new doors or adjusting existing prep 1 25mm Deep Drill holes 1 2 way through door then complete from other side to prevent splitting 2 1 8 54mm Dia 2 3 8 60mm or 2 3 4 70mm Backset 1 25mm Dia See Door Prep Template Inside of Door Frame Frame ...

Page 6: ...P N YRL LTSINSTL FUL Rev D 6 x4 1 Installing Latch Strike Plate Right Hand Installation Shown Outside of Door Frame ...

Page 7: ... D 7 2 Outside of Right Hand Door Inside of Right Hand Door Installing Touchscreen Right Hand Installation Shown TOP mark must be on top surface and tailpiece in vertical position Incorrect orientation will cause lock to fail ...

Page 8: ...P N YRL LTSINSTL FUL Rev D 8 x2 3 Installing Interior Mounting Plate Right Hand Installation Shown Inside of Right Hand Door Inside of Right Hand Door ...

Page 9: ...9 4 P N YRL LTSINSTL FUL Rev D Attaching the Cable Assembly Right Hand Installation Shown Inside of Right Hand Door ...

Page 10: ...P N YRL LTSINSTL FUL Rev D 10 5 X2 Installing Interior Lock Right Hand Installation Shown X Inside of Right Hand Door Click ...

Page 11: ...P N YRL LTSINSTL FUL Rev D 11 Outside of Right Hand Door Cylinder must be installed with bar away from latch Bar Latch 6 Installing Exterior Cylinder ...

Page 12: ... D 12 7 8 Installing Exterior Lever Installing Interior Lever Outside of Right Hand Door Inside of Right Hand Door Press pin while installing lever so lock is not damaged Press pin while installing lever so lock is not damaged ...

Page 13: ...N YRL LTSINSTL FUL Rev D 13 Testing Thumbturn Operation Outside of Right Hand Door Outside of Right Hand Door Test with door open If thumbturn operation test fails check installation beginning with Step 3 ...

Page 14: ...P N YRL LTSINSTL FUL Rev D 14 Testing Key Operation Outside of Right Hand Door Outside of Right Hand Door Test with door open If key operation test fails check installation beginning with Step 6 ...

Page 15: ...LTSINSTL FUL Rev D 15 9 Installing Optional Network Module NOTE If a network module was included with your lock it is in a separate box with additional module installation instructions Inside of Right Hand Door ...

Page 16: ...16 10 Inside of Right Hand Door Installing Batteries Cover Congratulations you ve installed the Yale Assure Lock Lever Touchscreen YRL226 Using Your Lock instructions will help you customize your lock Welcome to Yale Real Living ...

Page 17: ...on installation or after resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed See of Programming Instructions below 1 Enter Entry Code Press If touchscreen operation test fails check installation beginning with Step 2 Enter Entry Code Press OR ...

Page 18: ...batteries 2 Remove the interior lock to access the reset button 3 The reset button see image above is marked 4 Re insert 3 batteries and hold the reset button for 3 seconds 5 While still holding the reset button insert the 4th battery and hold the reset button for an additional 3 seconds 6 Release the reset button 7 Re install the interior lock onto the door Upon reset Master Entry Code creation i...

Page 19: ...k is properly seated on the mounting bracket b Ensure that the square shaped spindle has Top writing and arrow facing upwards c Place the tailpiece in the vertical position d Verify that the thumb turn is in the horizontal unlocked position I m getting an alert when I try to lock or unlock the door electronically a Do not turn or depress the lever during operation this could cause a jam alarm b Ch...

Page 20: ...en the latch is retracted activating the keypad will extend the latch during Auto Re lock duration or when Auto Re lock is disabled When One Touch Re lock is not in use disabled any valid PIN code will re lock the lock Volume Enabled Low The volume setting for entry code verification is set to Low 2 by default otherwise it can be set to High 1 or Silent 3 for quiet areas Language English Choosing E...

Page 21: ...or All Code Lockout Mode Indicator Battery Back up Hold a 9V battery to the terminals in case of dead lock batteries and no key Press to wake keypad or lock door Enter Master Entry Code and press to access Settings Menu Press to enter or unlock Interior Lock Thumbturn Inside Indicator Light Speaker Mechanical Key Back up entry method ...

Page 22: ...ing and use of lock is not possible until this step has been successfully completed Press Press Register Master Code Press the gear key to continue Enter a 4 to 8 digit code followed by PIN the gear key Registered Creating Master Entry Code Creating a Master Entry Code must be performed upon installation or after ...

Page 23: ...r Entry code Press Max user codes 250 with Network Module Max user codes 25 without Menu Mode enter number press the gear key to continue Press Adding more User Codes To end programming Press User Entry Codes Master Entry Code must be created first Enter 4 8 digit Entry Code Enter 4 8 digit Entry Code ...

Page 24: ...ress Press Press Press Deleting one entry code Enter 4 8 digit entry code Press To delete all entry codes Does not delete Master Entry Code Menu Mode enter number press the gear key to continue Press Press Enter To delete one entry code you must enter the entry code you wish to delete ...

Page 25: ... N Rev D YRL LTSINSTL FUL 24 Entry Code Management With Network ModuleUp to 250 Users Duplicate if necessary Entry Code Master Code Chart User Name 4 Press Unlocking Door with Entry Code Enter Entry Code ...

Page 26: ...in Disable 1 Press Yale logo to wake up lock 2 Enter Master Entry Code followed by icon Lock Response Welcome to the Settings Menu Press each number to hear available settings and then press the settings icon to enter 3 Enter digit corresponding to the function to be performed followed by the icon Follow the voice commands The Master Entry Code must be created prior to any other programming of the...

Page 27: ... batteries Check that the cable is firmly connected to the interior lock Check to see if Auto Re lock is enabled Disable Auto Re lock to lock the door manually If low battery indicator is lit change batteries Entry codes must consist of 4 to 8 digits The same entry code cannot be used for multiple users Management of entry codes is set by the authority of the Master Code which is set first Contact t...

Page 28: ...e interference by one or more of the following measures Industry Canada Cet appareillage numérique de la classe A répond à toutes les exigences de l interférence canadienne causant des règlements d équipement Class B Equipment Ÿ Consult the dealer or an experienced radio TV technician for help Ÿ Connect the equipment into an outlet on a circuit different from that to which the receiver is connecte...

Page 29: ... If you re adding a new Yale Smart Module follow the instructions included with it P N AYR202 ZW INSTAL FUL Rev E Removing a Yale Z Wave Plus Smart Module from your Assure Lock Z Wave System 1 Install the Yale Smart Module into the slot above the battery compartment IMPORTANT The batteries must be removed before removing the Yale Smart Module Remove battery cover Remove batteries Insert or remove ...

Page 30: ...on is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Industry Canada Ÿ Consult the dealer or an experienced radio TV technician for help THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS En ver...

Page 31: ...rated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network To Enroll the Module Inclusion Mode Enter the 4 8 digit Master code followed by the key PIN Press the key followed by the key Press the key followed by the key To Unenroll the Module Exclusion Mode Enter the 4 8 digit Master code followed by the key PIN Press the key followed by the key...

Page 32: ...ice may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux d Industrie CNR Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil...

Reviews: