23
Battery is fully charged
0x80
0x05
After a low battery alert was observed, the lock
was powered down and powered back up with
full battery.
0x08
0x0D
Handing Cycle
completed
0x81
0x00
Right-handed install
0x06
0xFE
0x01
Left-handed install
0x06
0xFE
Door Lock needs Time
set / RF Module Power
Cycled
0x82
0x00
Power to the lock was restored and the locks
RTC was cleared. The controller should set the
time to ensure proper logging.
0x08
0x01
Disabled user entered at
keypad
0x83
0x (01-
max
users)
A disabled user pin code was entered at the
keypad
0x06
0xFE
Valid user but outside of
schedule
0x84
0x (01-
max
users)
A valid user can be both a normal user and a
non-Access user. If a non-access user is out of
schedule this alarm will be sent instead of the
non-access alarm.
0x06
0xFE
Tamper Alarm
0xA1
0x01
keypad attempts exceed code entry limit
0x06
0X10
0x02
front escutcheon removed from main
0x06
0xFE
Low Battery Alarms ³
0xA7
0x
(Current
%)
Low Battery
Starting at 4.6V
0x08
0x0A
0xA8
0x
(Current
%)
Critical Battery Level
Starting at 4.4V
0x08
0x0B
Integrated BLE Lock
⁴
0xE2
0x00
Integrated BLE Lock
0x06
0x03
0x01
Integrated BLE Auto Relock
0x06
0x09
Integrated BLE Unlock
⁴
0xE3
0x00
Integrated BLE Unlock
0x06
0X04
0x01
Integrated BLE Auto Unlock
0x06
0X04
Homekit BLE Lock
⁴
0xE4
0x00
Integrated Homekit BLE Lock
0x06
0x03
Homekit BLE Unlock
⁴
0xE5
0x00
Integrated Homekit BLE Unlock
0x06
0X04
¹ Deleting all user codes will also delete any associated schedules (year day and daily repeating scheduled pin codes) assigned to user codes.
² This requires additional Hardware and calibration within the Yale Access App.
³ The Yale lock also supports a 3
rd
low battery alarm: too low to operate. This alarm is sent out as a Battery Report (with value = 0xFF)
through the Battery Command Class. This is the last low battery alarm level before the product stops functioning. Starting at 4.2V (0x8104)
⁴
Needs Yale Access App setup.