Yale Assure Lever YRL236 Installation And Programming Instructions Download Page 28

28

P/N YRL-LKFPBINSTL-FUL Rev A

Product Support Tel 1-855-213-5841 • www.yalehome.com

Ÿ

 Reorient or relocate the receiving antenna.

Equipment Regulations. 

FCC:

Class B Equipment 

Industry Canada:

Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

This equipment has been tested and found to comply with the limits for a Class B digital

Ÿ

 Increase the separation between the equipment and receiver.

Ÿ

 Connect the equipment into an outlet on a circuit different from that to which the  receiver is connected.

This Class A digital apparatus meets all requirements of the Canadian Interference Causing

Ÿ

 Consult the dealer or an experienced radio/TV technician for help.

Warning: 

Changes or modifications to this device, not expressly approved by 

ASSA ABLOY Residential Group, Inc.

 could void the 

user's authority to operate the equipment.

Yale® and Yale Real Living® are registered trademarks of ASSA ABLOY Residential Group, Inc.  

Assure Lever™ is a trademark of ASSA ABLOY Residential Group, Inc. 

Other products' brand names may be trademarks or registered trademarks of their respective 

owners and are mentioned for reference purposes only. 

© Copyright 2019. All rights reserved. Reproduction in whole or in part without the express written 

permission of ASSA ABLOY Residential Group, Inc. is prohibited.

Summary of Contents for Assure Lever YRL236

Page 1: ...Machine screws x2 Battery Cover Key AA Alkaline Batteries Latch Strike Plate Interior Mounting Plate Interior Lock Battery Cover Template Levers Before you begin for step by step installation instructions to register your product DOWNLOAD THE BILT APP Yale Assure Lever Key Free Push Button Installation and Programming Instructions YRL236 Optional Smart Module Key Free Cylinder Yale Smart Module is...

Page 2: ...L FUL Rev A 2 Preparing to Install Utility Knife Drill Wood Mortise Chisel Pencil Tape Measure Level Tools necessary only for new doors or adjusting existing prep Template Tools Needed Standard Phillips Head Screwdriver ...

Page 3: ...P N YRL LKFPBINSTL FUL Rev A 3 Checking Measurements 2 3 8 or 2 3 4 60mm or 70mm Backset 2 1 8 54mm Diameter 1 3 8 or 1 3 4 35mm or 44 5mm Door Thickness 1 25mm Diameter ...

Page 4: ...or Exterior Inswinging Door Interior Left Hand Reverse Right Hand Reverse Face a door swinging open toward you If it swings open to the right it is a right hand reverse door If it swings opens to the left it is a left hand reverse door Exterior Outswinging Door Interior Outside of Door Curve of latchbolt must contact strike plate first Frame Door Latchbolt Curve Strike Plate Exterior Optional Smar...

Page 5: ...Door Frame Necessary for new doors or adjusting existing prep 1 25mm Deep Inside of Door Frame Frame Drill holes 1 2 way through door then complete from other side to prevent splitting 2 1 8 54mm Dia 2 3 8 60mm or 2 3 4 70mm Backset 1 25mm Dia ...

Page 6: ... 6 x4 1 Installing Latch Strike Plate Right Hand Installation Shown 2 3 8 through bolt posts 2 3 4 through bolt posts Note Adjustment based on backset O optional default PULL Outside of Door Frame Backset 2 3 8 60mm or 2 3 4 70mm ...

Page 7: ...v A 7 2 Outside of Right Hand Door Inside of Right Hand Door Installing Push Button Right Hand Installation Shown TOP mark must be on top surface and tailpiece in vertical position Incorrect orientation will cause lock to fail ...

Page 8: ...P N YRL LKFPBINSTL FUL Rev A 8 x2 3 Installing Interior Mounting Plate Right Hand Installation Shown Inside of Right Hand Door Inside of Right Hand Door ...

Page 9: ...4 P N YRL LKFPBINSTL FUL Rev A Attaching the Cable Assembly Right Hand Installation Shown Use cable hooks for proper cable routing Inside of Right Hand Door Ensure cable is securely fastened into adapter ...

Page 10: ...P N YRL LKFPBINSTL FUL Rev A 10 5 X2 Installing Interior Lock Right Hand Installation Shown X Inside of Right Hand Door Click ...

Page 11: ...P N YRL LKFPBINSTL FUL Rev A 11 6 Installing Exterior Key Free Cylinder Outside of Right Hand Door Key free cylinder must be installed with bar away from latch Bar Latch ...

Page 12: ...P N YRL LKFPBINSTL FUL Rev A 12 7 Installing Exterior Lever Outside of Right Hand Door Press pin while installing lever so lock is not damaged ...

Page 13: ...P N YRL LKFPBINSTL FUL Rev A 13 8 Installing Interior Lever Inside of Right Hand Door Press pin while installing lever so lock is not damaged ...

Page 14: ...tside of Right Hand Door Outside of Right Hand Door Test interior and exterior operation with door open Test thumbturn and both levers in locked and unlocked positions If operation fails check installation beginning with Step 3 and refer to Hardware Troubleshooting ...

Page 15: ...nal Smart Module if included NOTE If a Smart module was included with your lock it is in a separate box with additional module installation instructions Inside of Right Hand Door Batteries must not be installed prior to inserting and or removing module ...

Page 16: ...STL FUL Rev A 16 10 Inside of Right Hand Door Installing Batteries Cover Congratulations you ve installed the Yale Assure Lever Key Free Push Button YRL236 Programming Instructions will help you customize your product ...

Page 17: ...be created upon installation or after resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed See of Programming Instructions below 1 If push button operation test fails check installation beginning with Step 2 Enter Entry Code Press ...

Page 18: ...reset button for 3 seconds 2 Remove the interior lock to access the reset button 7 Re install the interior lock onto the door Upon reset Master Entry Code creation is the only option available and must be performed prior to any other programming of the lock When resetting the lock all user codes including the Master Entry Code are deleted All programming features are reset to original default sett...

Page 19: ...me 60 Seconds Audio Mode Enabled One Touch Locking Enabled Inside Indicator Light Disabled Off Automatic Re lock Time 30 Seconds While Yale has included several features to prevent lockout 9 Volt battery jumper low battery warnings it is still possible for a lockout situation to occur Because this product does not have a mechanical override a key Yale recommends to use this product in an environme...

Page 20: ...in the horizontal unlocked position I m getting an alert when I try to lock or unlock the door electronically a Do not turn or depress the lever during operation this could cause a jam alarm b Check that thumb turn does not have anything preventing it from physically rotating c Verify that you can rotate thumb turn freely My lock is not making any sound when I push buttons a Using the programming ...

Page 21: ...P N YRL LKFPBINSTL FUL Rev A 21 Programming Instructions Speaker Master Entry Code must be created before any further programming Max User Codes 250 with Smart Module and 25 without ...

Page 22: ...r Entry Code Enter 4 8 digit Master Entry Code Creating a Master Entry Code must be performed upon installation or after resetting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed Press Press ...

Page 23: ...ress Press Press code flashes Press Enter Master Entry Code Press Master Entry Code must be created first Max user codes 250 with Smart Module and 25 without Enter 4 8 digit Entry Code Press Adding more User Codes To end programming Enter 4 8 digit Entry Code Press Press ...

Page 24: ...P N YRL LKFPBINSTL FUL Rev A 24 3 Unlocking Door with Entry Code Enter Entry Code Press Duplicate if necessary Code Chart User Name Entry Code Master Entry Code Management ...

Page 25: ...de the lock will automatically re lock after thirty 30 seconds Audio Mode The audio setting for entry code verification is set to Enable 1 by default otherwise it can be set to Disable 3 for quiet areas Inside Indicator Light Located on the interior escutcheon Shows active status Locked of lock and can be enabled or disabled in the Advanced Lock Settings Main Menu selection 3 Low Battery When batte...

Page 26: ... lock M U This function appears only with network module installed Default settings in bold Master PIN Code Setting User PIN Code Registration Continue Complete Register Delete Continue Complete M 2 1 Join the Network Enable Disable Disable Enable Complete Exit the Network Audio Mode All Code Lockout Mode Network Module Setting Advanced Lock Settings Automatic Re lock Disable 30 sec Inside Indicat...

Page 27: ...g Symptom Suggested Action When batteries are replaced Smart Module locks have a real time clock that will be set through the User Interface UI it is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time DST ...

Page 28: ...r is encouraged to try to correct the interference by one or more of the following measures This equipment has been tested and found to comply with the limits for a Class B digital Ÿ Increase the separation between the equipment and receiver Ÿ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected This Class A digital apparatus meets all requiremen...

Page 29: ...ion Mode Enter the 4 8 digit Master code followed by the key PIN Press the key followed by the key Press the key followed by the key To Unenroll Remove the Module Exclusion Mode Enter the 4 8 digit Master code followed by the key PIN Press the key followed by the key Press the key followed by the key Factory Reset If No Controller See the Lock Installation Manual Please use this procedure only whe...

Page 30: ...que d interférence aux autres utilisateurs le type d antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente ne dépasse pas ce qui est PIRE nécessaire pour une communication réussie Section 7 1 3 of RSS GEN This Device complies with Industry Canada License exempt standard s RSS Operation is subject to the following two conditions 1 this device may not caus...

Page 31: ...rated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network To Enroll the Module Inclusion Mode Enter the 4 8 digit Master code followed by the key PIN Press the key followed by the key Press the key followed by the key To Unenroll the Module Exclusion Mode Enter the 4 8 digit Master code followed by the key PIN Press the key followed by the key...

Page 32: ...ice may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux d Industrie CNR Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil...