background image

1033348-15/15

dIsAsseMblY

reMove all gear and accessories. 

• Use 5/32” hex wrench to loosen coupler sleeve screws, 

open couplers. 

• Remove hoops. If coupler housings remain attached to 

hoops, pull the housings off the hoop. 

• Slide coupler housings up. Open coupler sleeves and 

remove.

• Remove floor screws from foot disks. 
• Remove wall screws from wall plates or Universal Mounting 

Plate. (If using Universal Mounting Plate, remove screws 

from back of plate and detach vertical assembly.) 

• Detach top tube by pulling top sleeve from the vertical pole. 
• Remove sleeve and unscrew wall plate from top tube. 
• Detach foot assembly by pulling bottom sleeve from the 

vertical pole. Remove sleeve. 

• Unscrew foot disk from foot tube.  
• Disassemble hoops: Depress pegs in connectors and pull 

side tubes away from hoops. 

CARe ANd 

MAINTeNANCe

Wipe with a wet cloth or use a 

solution of soap and water. do 

not use abrasive cleaners
.

• Unit must be secured to walls at 

four locations. 

• If storing heavy items, feet must 

be secured to the floor. 

• Prior to each use check for any 

loose parts, wear, or damage. 

Discontinue use immediately 

if the unit should become 

damaged or malfunctions. 

• Replace any cracked or bent 

parts immediately.

This product is covered by

YAKIMA’s 

“Love It Till You Leave It”

 limited lifetime Warranty

To obtain a copy of this warranty, go online to www.yakima.com

or email us at [email protected]

or call (888) 925-4621

K E E P   T H E S E   I N S T R U C T I O N S !

dO NOT OveRlOAd ThIs PROduCT

Approximate base unit load Capacity:

800 lbs. evenly distributed over product

 

 

Approximate hoop load Capacity:

 

 

 

 

    200 lbs. eACh hOOP

overloading this product could result in serious injury or damage to property.

TeChNICAl AssIsTANCe OR RePlACeMeNT PARTs

CONTACT YOuR deAleR OR CAll (888)925-4621

MONdAY ThROuGh fRIdAY, 7:00 AM TO 5:00 PM, PsT

37

Summary of Contents for GroundControl

Page 1: ...talled by a professional installer such as a licensed contractor Incorrect installation use of unauthorized parts or unintended use of this product may void your warranty use supplied hardware Use onl...

Page 2: ...red Tools Power Drill 1 8 drill bit Pen or Pencil 12 tape measure 24 level Stud Finder for walls with hidden studs Horizontal Pieces Horizontal Connectors x12 Stud Finder Magnet style stud finders are...

Page 3: ...covering see Installing on Bare Studs special instructions If you need to secure GroundControl to a concrete or masonry wall use the optional Anchor Kit available from your authorized YAKIMA GroundCo...

Page 4: ...s of the horizontal tubes to complete one hoop ASSEMBLE HORIZONTAL HOOPS Attach wall plates to top tubes or use Mounting Plate If your wall studs are not 32 apart you must use the Universal Mounting P...

Page 5: ...end of the foot tube all the way onto foot disk but do not tighten 5 6 Assemble vertical sleeves onto foot tubes 7 Combine foot tube assemblies to vertical tubes Enclose the metal tube inside the two...

Page 6: ...ies Use this hole for walls with studs Attach wall plates to strut tubes The convex bumps of the plate go into the end of the top tube Secure with plate screw If you are using Universal Mounting Plate...

Page 7: ...r to accommodate the difference in wall depths Concrete or masonry requires the Anchor Kit Follow Anchor kit instructions If your floor is uneven adjust the height of the feet until unit is level Dete...

Page 8: ...n yet Attach strut tubes to walls 18 check the distance again 32 81 28 cm Couplers LOOSEN the screws on the couplers Slide the coupler housings off the sleeves Open the coupler sleeves 19 Sleeve Housi...

Page 9: ...nging sleeve screws and hand tighten the with the included 5 32 hex key do not over tighten Concrete Floors Do not drill through the feet The concrete bit can cause damage to the feet It may be necess...

Page 10: ...be added to either side of your GroundControl Unit More than one kit can be added depending upon the available space Before you Begin The Extender Kit increases the width of the GroundControl by 32 in...

Page 11: ...s by pulling them from the hoop Leave couplers attached Depress pegs on the horizontal tubes and pull side tube away from hoop Leave connectors in the side tubes Remove side tubes from the side that w...

Page 12: ...he entire unit before assembly and installation Review measurements in Step 31 and 32 You may need one or more Universal Mounting Plates if the wall studs do not align with the installation KIT CONTEN...

Page 13: ...er 31 Outer corners require vertical assemblies be attached to the wall at 13 3 8 from the corner From the corner measure 13 3 8 13 97 cm Mark this measurement Add 32 81 28 cm from the mark away from...

Page 14: ...lies 36 existing installations remove hoops then side tubes new installations begin at step 1 If you have an installed Base Unit and you are adding a Corner Kit and Base Unit you must detach the stand...

Page 15: ...NCE Wipe with a wet cloth or use a solution of soap and water Do not use abrasive cleaners Unit must be secured to walls at four locations If storing heavy items feet must be secured to the floor Prio...

Reviews: