70
WIRES-X Software
Main Screen
●
Receiving status
The signal receiving status of the node and the repeating status of the received signal are shown.
During digital operation (DW), or when using two transceivers; one for the voice channel and the other for the preset search channel,
two identical icons will appear. In this case, the upper icon indicates the voice channel status and the lower icon indicates the preset
search channel status.
Not receiving
Receiving an analog signal, or receiving an SQL code signal which is not in accordance with your node setting (when
using a digital transceiver)
Receiving an SQL code signal which is in accordance with the your node setting, but not repeating (when using a
digital transceiver)
Receiving a signal and repeating to a node or room on the Internet (only for the voice channel)
Tip
For details on the SQL code setting, refer to “Settings for the transceiver” (page 75).
●
Device connection status
The connection status of the transceiver(s) to the HRI-200 and to your PC is shown.
An analog transceiver is connected to the HRI-200 properly
Caution
If this icon appears even when a digital transceiver is connected, check the connection of the transceiver to the HRI-200
again.
A digital transceiver is connected to the HRI-200 properly
Two digital transceivers are connected to the HRI-200 properly
The HRI-200 is not connected or there is a problem with the connection
Caution
If this icon appears, close the WIRES-X software, check the connection, then restart the software.
●
DTMF signal detection status
Shows whether the HRI-200 detects the DTMF signal or not. The icon appears only for an analog operation.
Not detecting
Detecting
●
Transmission timeout timer
While transmitting, the remaining time before transmission automatically stops is shown.
1 to 3 minutes left
20 to 59 seconds left
1 to 19 seconds left
No remaining time (3 minutes has passed)
Tip
“0:00” will flash.
Caution
With WIRES-X, individual transmissions must be less than 3 minutes in duration. Be careful not to make a continuous transmission longer than 3 minutes.
User monitoring window
Displays the information below the status indicators, of the digital node (mobile or fixed) that is accessing your node.