7
automatic device, to comply with the FCC rule Part 97: Sec.97.119(b)(1)Station identification.
Caution2 (INTERVAL)
When operating in the USA the ID setting time should be ten minutes or less to comply with the FCC rule
Part 97: Sec.97.119(a)Station identification.
[TX INHIBIT]
Set transmit inhibit.
Mode : Set the TX INHIBIT function.
• OFF:
Permit repeater transmissions
• ON:
Restrict transmission
• REMOTE: Remote transmit control by ECS(Enhanced Code Squelch) code.
STOP/RESUME CODE : Set the ECS(Enhanced Code Squelch)code for remote TX control.
Note
The selected ECS code, must meet the following conditions:
• Analog SQL is 151.4Hz or less (ToneSQL), or “DCS”: 01(67 Hz) to 25 (151.4 Hz)
• Analog SQL is 156.7Hz or higher (ToneSQL), or “No Tone”: 26 (156.7 Hz) to 50 (254.1 Hz)
[DISP TIMER]
Set the repeater touch panel automatic light timer.