20
VX-8R/E and VX-8DR/E Technical Supplement
B-Band 50 MHz Band Adjustment
Press the [
BAND
] key to select the 50 MHz Amateur band.
Receiver Sensitivity Adjustment (TUNE DC)
Ì
Connect the test equipment as shown in Figure 2: RX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
TUNE DC
".
Ì
Set the RF Signal Generator output to 52.100 MHz, at a
level of -10 dBµ, ±3.5 kHz deviation with a 1 kHz audio
tone.
Ì
Press the [
V/M
] button (the "
" icon will appear on
the display).
Ì
Rotate the DIAL knob for maximum deflection on the
SINAD meter.
Ì
Press the [
V/M
] button (the "
" icon will disappear on
the display).
Squelch Hysteresis Confirmation (HIS SQL)
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
HIS SQL
".
Confirm that the alignment value is "0".
Squelch Threshold Adjustment (THLD SQL)
Ì
Connect the test equipment as shown in Figure 2: RX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"THLD SQL".
Ì
Set the RF Signal Generator output to 52.100 MHz, at a
level of -11 dBµ, ±3.5 kHz deviation with a 1 kHz audio
tone.
Ì
Press the [
V/M
] button (the "
" icon will appear on
the display).
Ì
Press the [
F/W
] key two times to store the Squelch
Threshold level.
Ì
Press the [
V/M
] button (the "
" icon will disappear on
the display).
Tight Squelch Adjustment (TIGH SQL)
Ì
Connect the test equipment as shown in Figure 2: RX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"TIGH SQL".
Ì
Set the RF Signal Generator output to 52.100 MHz, at a level
of -3 dBµ, ±3.5 kHz deviation with a 1 kHz audio tone.
Ì
Press the [
V/M
] button (the "
" icon will appear on
the display).
Ì
Press the [
F/W
] key two times to store the Squelch
Tight level.
Ì
Press the [
V/M
] button (the "
" icon will disappear on
the display).
FM S-Meter S-1 Adjustment (S1 LEVEL)
Ì
Connect the test equipment as shown in Figure 2: RX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
S1 LEVEL
" with "
NFM
" icon.
Ì
Set the RF Signal Generator output to 52.100 MHz, at a
level of -7 dBµ, ±3.5 kHz deviation with a 1 kHz audio
tone.
Ì
Press the [
V/M
] button (the "
" icon will appear on
the display).
Ì
Press the [
F/W
] key two times to store the FM S-Meter
S-1 level.
Ì
Press the [
V/M
] button (the "
" icon will disappear on
the display).
FM S-Meter Full-Scale Adjustment (S9 LEVEL)
Ì
Connect the test equipment as shown in Figure 2: RX
Alignment Setup.
Ì
Rotate the
DIAL
knob to select the Alignment Menu
"
S9 LEVEL
" with "
NFM
" icon.
Ì
Set the RF Signal Generator output to 52.100 MHz, at a
level of +20 dBµ, ±3.5 kHz deviation with a 1 kHz au-
dio tone.
Ì
Press the [
V/M
] button (the "
" icon will appear on
the display).
Ì
Press the [
F/W
] key two times to store the FM S-Meter
Full Scale level.
Ì
Press the [
V/M
] button (the "
" icon will disappear on
the display).
Alignment
Summary of Contents for VX-8R/E
Page 5: ...5 VX 8R E and VX 8DR E Technical Supplement Block Diagram...
Page 6: ...6 VX 8R E and VX 8DR E Technical Supplement Block Diagram Note...
Page 25: ...25 RF Unit Lot 1 4 VX 8R E Technical Supplement Circuit Diagram...
Page 27: ...27 RF Unit Lot 5 7 VX 8R E Technical Supplement Circuit Diagram...
Page 47: ...47 RF 2 Unit Lot 8 15 VX 8R E Technical Supplement Circuit Diagram...
Page 49: ...49 RF 2 Unit Lot 16 VX 8R E Technical Supplement Circuit Diagram...
Page 51: ...51 RF 2 Unit Lot 24 VX 8R E and VX 8DR Technical Supplement Circuit Diagram...
Page 73: ...73 CNTL Unit Lot 1 4 VX 8R E Technical Supplement Circuit Diagram...
Page 75: ...75 CNTL Unit Lot 5 7 VX 8R E Technical Supplement Circuit Diagram...
Page 87: ...87 CNTL 2 Unit Lot 8 15 VX 8R E Technical Supplement Circuit Diagram...
Page 89: ...89 CNTL 2 Unit Lot 16 VX 8R E Technical Supplement Circuit Diagram...
Page 91: ...91 CNTL 2 Unit Lot 24 VX 8R E and VX 8DR Technical Supplement Circuit Diagram...
Page 104: ...104 VX 8R E Technical Supplement Note CONNECTOR Unit Lot 1 7...
Page 106: ...106 VX 8R E and VX 8DR E Technical Supplement Note CONNECTOR 2 Unit Lot 8...
Page 108: ...108 VX 8R E and VX 8DR E Technical Supplement Note MAIN VCO Unit...
Page 112: ...112 VX 8R E and VX 8DR E Technical Supplement Note MAIN VCO Unit...
Page 114: ...114 VX 8R E and VX 8DR E Technical Supplement Note SUB VCO Unit...
Page 117: ...117 VX 8R E and VX 8DR E Technical Supplement...