12
50 MHz band
Press the [
BAND
] button to switch the alignment band to
50 MHz Band.
Squelch Threshold Adjustment
P
Connect the RF Signal Generator to the ANT jack, and
then set the output level to -4 dB
μ
V at the 52.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).
P
Rotate the DIAL knob one click clockwise to select the
alignment item "tHL".
P
Press the [
V/M
] key.
P
Press the [
F/W
] key twice, and then press the [
V/M
] key
again.
Squelch Tight Adjustment
P
Connect the RF Signal Generator to the ANT jack, and
then set the output level to +3 dB
μ
V at the 52.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).
P
Rotate the DIAL knob one click clockwise to select the
alignment item "tIg".
P
Press the [
V/M
] key.
P
Press the [
F/W
] key twice, and then press the [
V/M
] key
again.
NFM S-Meter S-1 Adjustment
P
Connect the RF Signal Generator to the ANT jack, and
then set the output level to 0 dB
μ
V at the 52.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).
P
Rotate the DIAL knob one click clockwise to select the
alignment item "S1".
P
Press the [
V/M
] key.
P
Press the [
F/W
] key twice, and then press the [
V/M
] key
again.
NFM S-Meter Full Scale Adjustment
P
Connect the RF Signal Generator to the ANT jack, and
then set the output level to +20 dB
μ
V at the 52.100 MHz
(with 1 kHz tone @ ±3.5 kHz deviation).
P
Rotate the DIAL knob one click clockwise to select the
alignment item "S9".
P
Press the [
V/M
] key.
P
Press the [
F/W
] key twice, and then press the [
V/M
] key
again.
Alignment
WFM S-Meter S-1 Adjustment
P
Connect the RF Signal Generator to the ANT jack, and
then set the output level to +8 dB
μ
V at the 52.100 MHz
(with 1 kHz tone @ ±20 kHz deviation).
P
Rotate the DIAL knob one click clockwise to select the
alignment item "S1".
P
Press the [
V/M
] key.
P
Press the [
F/W
] key twice, and then press the [
V/M
] key
again.
WFM S-Meter Full Scale Adjustment
P
Connect the RF Signal Generator to the ANT jack, and
then set the output level to +25 dB
μ
V at the 52.100 MHz
(with 1 kHz tone @ ±20 kHz deviation).
P
Rotate the DIAL knob one click clockwise to select the
alignment item "S9".
P
Press the [
V/M
] key.
P
Press the [
F/W
] key twice, and then press the [
V/M
] key
again.
Summary of Contents for VX-3R
Page 5: ...5 Block Diagram...
Page 6: ...6 Note...
Page 15: ...15 Circuit Diagram MAIN Unit Lot 1 3...
Page 16: ...16 Note MAIN Unit Lot 1 3...
Page 19: ...19 MAIN Unit Lot 4 Circuit Diagram...
Page 20: ...20 MAIN Unit Lot 4 Note...
Page 36: ...36 Note Main Unit...
Page 37: ...37 Filter Unit Circuit Diagram...
Page 40: ...40 Filter Unit Note...
Page 41: ...41 SW Unit Lot 1 3 Circuit Diagram...
Page 43: ...43 SW Unit Lot 4 Circuit Diagram...
Page 47: ...47 VCO Unit Circuit Diagram...
Page 51: ...51...