Yaesu VX-160U Alignment Manual Download Page 3

VX-160U/180U

Alignment

3

Receiver

Receiver

Receiver

Receiver
Set up the test equipment as shown for receiver alignment.

Sensitivity

ˆ

 

Set the transceiver to CH 3 (high band edge)

ˆ

 

Tune the RF signal generator to the same frequency of the transceiver, then set the
generator output level to 40 µV with ±3.0 kHz deviation @ 1 kHz tone modulation.

ˆ

 

Open the “Adjust

Adjust

Adjust

Adjust” window on the CE44, then select “Sensitivity

Sensitivity

Sensitivity

Sensitivity” parameter.

ˆ

 

Press the 

[

ENTER

]

 key to enable programming of this parameter, use the [

UP

] or

[

Down

] arrow keys so that the RF signal generator output level should be –7dB or

less for 12 dB SINAD.