VX-160U/180U
Alignment
3
Receiver
Receiver
Receiver
Receiver
Set up the test equipment as shown for receiver alignment.
Sensitivity
Set the transceiver to CH 3 (high band edge)
Tune the RF signal generator to the same frequency of the transceiver, then set the
generator output level to 40 µV with ±3.0 kHz deviation @ 1 kHz tone modulation.
Open the “Adjust
Adjust
Adjust
Adjust” window on the CE44, then select “Sensitivity
Sensitivity
Sensitivity
Sensitivity” parameter.
Press the
[
ENTER
]
key to enable programming of this parameter, use the [
UP
] or
[
Down
] arrow keys so that the RF signal generator output level should be –7dB or
less for 12 dB SINAD.