FTM-400DR/DE Technical Supplement
Alignment
ALIGNMENT-8
Center Meter Calibration
1. Set the RF signal generator to 440.050 MHz. Set
the generator for ±3.5 kHz deviation of a 1 kHz
modulation tone, and set the RF output level
from the signal generator to +10 dBμV.
2. Set the transceiver frequency to 440.050 MHz.
3. Press the [
D
(
X
)
] key to select "FM".
4. Press the [
P1
] key of the Microphone to set the
alignment menu Item to "
Adj 07 CTR/A
".
5. Press the [
P3
] key
to save the new setting.
6. Set the transceiver frequency to 440.050 MHz of
the Band B.
7. Press the [
D
(
X
)
] key to select "FM".
8. Press the [
P2
] key of the Microphone to set the
alignment menu Item to "
Adj 07 CTR/B
".
9. Press the [
P3
] key
to save the new setting.
To close the alignment mode, just turn the power
off bypressing and holding the [
POWER
(
LOCK
)
]
switch for two seconds. The next time the trans-
ceiver is turned on, normaloperation will resume.
Summary of Contents for FTM-400DR/DE
Page 5: ...BLOCK DIAGRAM 1 FTM 400DR DE Technical Supplement Block Diagram...
Page 14: ...FTM 400DR DE Technical Supplement MAIN 1 MAIN Unit Circuit Diagram...
Page 16: ...FTM 400DR DE Technical Supplement MAIN 3 MAIN Unit Side B a b d f c e 1 2 3 5 4 6 g...
Page 48: ...FTM 400DR DE Technical Supplement PANEL 1 PANEL Unit Circuit Diagram...
Page 49: ...FTM 400DR DE Technical Supplement PANEL 2 PANEL Unit Parts Layout Side A A B D F C E 1 2 3 4 G...
Page 50: ...FTM 400DR DE Technical Supplement PANEL 3 PANEL Unit Side B a b d f c e 1 2 3 4 g...
Page 55: ...FTM 400DR DE Technical Supplement DSP 1 DSP Unit Circuit Diagram...
Page 56: ...FTM 400DR DE Technical Supplement DSP 2 DSP Unit Parts Layout Side A Side B A B 1 2...