FT2DR/DE Technical Supplement
Alignment
ALIGNMENT-7
Tight Squelch Adjustment (TIGH SQL)
Connect the test equipment as shown in Figure 2:
RX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "
TIGH SQL
".
Set the RF Signal Generator output to 145.100
MHz, at a level of -4 dBμ, ±3.5 kHz deviation
with a 1 kHz audio tone.
Press the [
V/M
] button (the "Data" will appear
on the display).
Press the [
X
] key two times to store the Squelch
Tight level.
Press the [
V/M
] button (the "Data" will disap-
pear on the display).
FM S-Meter S-1 Adjustment (S1 LEVEL)
Connect the test equipment as shown in Figure 2:
RX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "
S1 LEVEL
".
Set the RF Signal Generator output to 145.100
MHz, at a level of -7 dBμ, ±3.5 kHz deviation
with a 1 kHz audio tone.
Press the [
V/M
] button (the "Data" will appear
on the display).
Press the [
X
] key two times to store the FM
S-Meter S-1 level.
Press the [
V/M
] button (the "Data" will disap-
pear on the display).
FM S-Meter Full-Scale Adjustment (S9 LEVEL)
Connect the test equipment as shown in Figure 2:
RX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "
S9 LEVEL
".
Set the RF Signal Generator output to 145.100
MHz, at a level of +20 dBμ, ±3.5 kHz deviation
with a 1 kHz audio tone.
Press the [
V/M
] button (the "Data" will appear
on the display).
Press the [
X
] key two times to store the FM
S-Meter Full Scale level.
Press the [
V/M
] button (the "Data" will disap-
pear on the display).
TX Power (HI) Adjustment (HI POWER)
Connect the test equipment as shown in Figure 1:
TX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "
HI POWER
".
Press the [
V/M
] button (the "Data" will appear
on the display).
Press the
PTT
switch to transmit and rotate the
DIAL
knob so that the Power Meter setting is
4.9 W (±0.05 W).
Release the
PTT
switch, then press the [
V/M
]
button (the "Data" will disappear on the dis-
play).
TX Power (L3) Adjustment (L3 POWER)
Connect the test equipment as shown in Figure 1:
TX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "
L3 POWER
".
Press the [
V/M
] button (the "Data" will appear
on the display).
Press the
PTT
switch to transmit and rotate the
DIAL
knob so that the Power Meter setting is
2.5 W (±0.1 W).
Release the
PTT
switch, then press the [
V/M
]
button (the "Data" will disappear on the dis-
play).
TX Power (L2) Adjustment (L2 POWER)
Connect the test equipment as shown in Figure 1:
TX Alignment Setup.
Rotate the
DIAL
knob to select the Alignment
Menu "
L2 POWER
".
Press the [
V/M
] button (the "Data" will appear
on the display).
Press the
PTT
switch to transmit and rotate the
DIAL
knob so that the Power Meter setting is
0.9 W (+0.05/-0.1 W).
Release the
PTT
switch, then press the [
V/M
]
button (the "Data" will disappear on the dis-
play).
Summary of Contents for FT2DR
Page 5: ...BLOCK DIAGRAM 1 FT2DR DE Technical Supplement Block Diagram...
Page 17: ...FT2DR DE Technical Supplement RF 1 Circuit Diagram RF Unit Lot 1 2...
Page 19: ...FT2DR DE Technical Supplement RF 3 RF Unit Lot 3 Circuit Diagram...
Page 21: ...FT2DR DE Technical Supplement RF 5 RF Unit Lot 4 6 Circuit Diagram...
Page 23: ...FT2DR DE Technical Supplement RF 7 RF Unit Lot 7 Circuit Diagram...
Page 43: ...FT2DR DE Technical Supplement CNTL 1 Circuit Diagram CNTL Unit Lot 1 2...
Page 45: ...FT2DR DE Technical Supplement CNTL 3 Circuit Diagram CNTL Unit Lot 3 6...
Page 47: ...FT2DR DE Technical Supplement CNTL 5 Circuit Diagram CNTL Unit Lot 7...
Page 57: ...FT2DR DE Technical Supplement SUB 1 SUB Unit Circuit Diagram...
Page 58: ...FT2DR DE Technical Supplement SUB 2 SUB Unit Parts Layout Side A Side B...
Page 63: ...ENC 1 Circuit Diagram Parts Layout Side A Side B ENC Unit FT2DR DE Technical Supplement...