![Yaesu FT DX 9000 - CAT OPERATION REFERENCE BOOK Reference Download Page 17](http://html1.mh-extra.com/html/yaesu/ft-dx-9000-cat-operation-reference-book/ft-dx-9000-cat-operation-reference-book_reference_3122132017.webp)
FT
DX
9000 S
ERIES
CAT O
PERATION
R
EFERENCE
CAT
(
C
OMPUTER
A
IDED
T
RANSCEIVER
)
O
PERATION
R
R
R
R
RT
T
T
T
T
CLAR
Set
1
2
3
4
5
6
7
8
9
10
R
T
P1
;
Read
1
2
3
4
5
6
7
8
9
10
R
T
;
Answer
1
2
3
4
5
6
7
8
9
10
R
T
P1
;
P1 0: RX Clarifier “OFF”
1: RX Clarifier “ON”
R
R
R
R
RU
U
U
U
U
RX CLARIFIER PLUS OFFSET
Set
1
2
3
4
5
6
7
8
9
10
R
U
P1 P1 P1 P1
;
Read
1
2
3
4
5
6
7
8
9
10
Answer
1
2
3
4
5
6
7
8
9
10
P1 0000 - 9999 (Hz)
SC
SC
SC
SC
SC
SCAN
Set
1
2
3
4
5
6
7
8
9
10
S
C
P1
;
Read
1
2
3
4
5
6
7
8
9
10
S
C
;
Answer
1
2
3
4
5
6
7
8
9
10
S
C
P1
;
P1 0: Scan “OFF”
1: Scan “ON” (Upward)
2: Scan “ON” (Downward)
C
ONTROL
C
OMMAND
T
ABLES
R
R
R
R
RO
O
O
O
O
ROTATOR
Set
1
2
3
4
5
6
7
8
9
10
R
O
P1
;
Read
1
2
3
4
5
6
7
8
9
10
R
O
;
Answer
1
2
3
4
5
6
7
8
9
10
R
O
P1 P2 P2 P2 P3 P3 P3
;
P1 0: OFF
1: Counter Clockwise
2: Clockwise
3: SPEED 1 % DOWN
4: SPEED 1 % UP
P2 DIRECTION (0 - 450 degree)
P3 SPEED (0 - 100 %)
RS
RS
RS
RS
RS
RADIO STATUS
Set
1
2
3
4
5
6
7
8
9
10
Read
1
2
3
4
5
6
7
8
9
10
R
S
;
Answer
1
2
3
4
5
6
7
8
9
10
R
S
P1
;
P1 0: NORMAL MODE
1: MENU MODE
2: MENU DATA READ (from CF Card)
Page 16
SD
SD
SD
SD
SD
CW BREAK-IN DELAY TIME
Set
1
2
3
4
5
6
7
8
9
10
S
D
P1 P1 P1 P1
;
Read
1
2
3
4
5
6
7
8
9
10
S
D
;
Answer
1
2
3
4
5
6
7
8
9
10
S
D
P1 P1 P1 P1
;
P1 0000: Full Break-in
0001 - 5000 mS
SF
SF
SF
SF
SF
SUB VFO-B KNOB FUNCTION
Set
1
2
3
4
5
6
7
8
9
10
S
F
P1 P1
;
Read
1
2
3
4
5
6
7
8
9
10
S
F
;
Answer
1
2
3
4
5
6
7
8
9
10
S
F
P1 P1
;
P1 00: OFF (Read only)
05: BAND (Sub (VFO-B) Band)
01: BAND (Main (VFO-A) Band)
06: MHz (Sub (VFO-B) Band)
02: MHz (Main (VFO-A) Band)
07: FAST (Sub (VFO-B) Band)
03: GRP
08: A/B
04: MCH
09: CLAR
10: MODE (Sub (VFO-B) Band)
RL
RL
RL
RL
RL
NOISE REDUCTION LEVEL
Set
1
2
3
4
5
6
7
8
9
10
R
L
P1 P2 P2
;
Read
1
2
3
4
5
6
7
8
9
10
R
L
P1
;
Answer
1
2
3
4
5
6
7
8
9
10
R
L
P1 P2 P2
;
P1 0: Main (VFO-A) Band Receiver
1: Sub (VFO-B) Band Receiver
P2 01 - 15
RM
RM
RM
RM
RM
READ METER
Set
1
2
3
4
5
6
7
8
9
10
Read
1
2
3
4
5
6
7
8
9
10
R
M
P1 P1
;
Answer
1
2
3
4
5
6
7
8
9
10
R
M
P1 P1 P2 P2 P2
;
P1 00: Current Main Meter
01: Current Sub Meter
02: Current VDD/BIAS Meter
(Contest/MP versions)
03: Current TEMP/SWR Meter
(Contest/MP versions)
04: S Meter (Main)
05: S Meter (Sub)
06: COMP Meter
07: ALC Meter
08: PO Meter
09: SWR Meter
10: ID Meter
P2 000 - 255
11: VDD Meter
12: MIC Meter
13: BIAS Meter
14: TEMP Meter