12
FT-60R/E Technical Supplement
CTCSS TX Deviation
1. Tune the frequency to 440.050 MHz, then activate the
CTCSS encoder with a “100 Hz” tone, and set the trans-
mit power level to “LOW.”
2. Press the [
F/W
] key, then press the [
BAND
(
BAND DN
)]
key to set the alignment parameter to “
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
.”
3. With in five second of appearing the “
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
” on
the display, press the
PTT
switch to activate the trans-
mitter (with no microphone input), adjust the
DIAL
knob so that the deviation meter reading is 0.7 kHz
(±0.05 kHz).
4. Tune the frequency to 146.050 MHz, then activate the
CTCSS encoder with a “100 Hz” tone, and set the trans-
mit power level to “LOW.”
5. Press the [
F/W
] key to recall the alignment parameter
to “
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
.”
6. With in five second of appearing the “
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
A5 CTC.xxx
” on
the display, press the
PTT
switch to activate the trans-
mitter (with no microphone input), adjust the
DIAL
knob so that the deviation meter reading is 0.7 kHz
(±0.05 kHz).
S-meter Sensitivity
1. Tune the frequency to 440.050 MHz.
2. Inject a 440.050 MHz signal at a level of –5 dB
μ
V (with
1 kHz modulation @±3.5 kHz deviation) from the RF
signal generator.
3. Press the [
F/W
] key, then press the [
BAND
(
BAND DN
)]
key to set the alignment parameter to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
4. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
5. Increase the RF signal generator output level to +23
dB
μ
V.
6. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
7. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
8. Tune the frequency to 850.050 MHz.
9. Inject a 850.050 MHz signal at a level of +5 dB
μ
V (with
1 kHz modulation @±3.5 kHz deviation) from the RF
signal generator.
10. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
11. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
12. Increase the RF signal generator output level to +31
dB
μ
V.
13. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
14. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
Alignment
15. Tune the frequency to 146.050 MHz.
16. Inject a 146.050 MHz signal at a level of –5 dB
μ
V (with
1 kHz modulation @±3.5 kHz deviation) from the RF
signal generator.
17. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
18. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
19. Increase the RF signal generator output level to +23
dB
μ
V.
20. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
21. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
22. Tune the frequency to 230.050 MHz.
23. Inject a 230.050 MHz signal at a level of –5 dB
μ
V (with
1 kHz modulation @±3.5 kHz deviation) from the RF
signal generator.
24. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
25. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
26. Increase the RF signal generator output level to +23
dB
μ
V.
27. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
28. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
29. Tune the frequency to 350.050 MHz.
30. Inject a 350.050 MHz signal at a level of –5 dB
μ
V (with
1 kHz modulation @±3.5 kHz deviation) from the RF
signal generator.
31. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
32. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
33. Increase the RF signal generator output level to +23
dB
μ
V.
34. Press the [
F/W
] key to recall the alignment parameter
to “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
.”
35. With in five second of appearing the “
A6 SM U
A6 SM U
A6 SM U
A6 SM U
A6 SM U
/
D
D
D
D
D
” on
the display, press the [
(
MHz
)] key.
DC Voltmeter
1. Set the power supply voltage to 9.9 V.
2. Press the [
F/W
] key, then press the [
BAND
(
BAND DN
)]
key to set the alignment parameter to “
A7 BAT RV
A7 BAT RV
A7 BAT RV
A7 BAT RV
A7 BAT RV
.”
3. With in five second of appearing the “
A7 BAT RV
A7 BAT RV
A7 BAT RV
A7 BAT RV
A7 BAT RV
” on
the display, press the [
HM/RV
] key.
To close the alignment mote, just turn the power off by rotating
the
VOL
knob fully counter clockwise. The next time the trans-
ceiver is turned on, normal operation may resume.
Summary of Contents for FT-60R/E
Page 4: ...4 FT 60R E Technical Supplement Exploded View Miscellaneous Parts Note...
Page 5: ...5 Block Diagram FT 60R E Technical Supplement...
Page 6: ...6 Block Diagram FT 60R E Technical Supplement Note...
Page 14: ...Note MAIN Unit Lot 1 5 14 FT 60R E Technical Supplement...
Page 17: ...Circuit Diagram MAIN Unit Lot 6 9 17 FT 60R E Technical Supplement...
Page 18: ...Note MAIN Unit Lot 6 9 18 FT 60R E Technical Supplement...
Page 21: ...Circuit Diagram MAIN Unit Lot 10 11 21 FT 60R E Technical Supplement...
Page 22: ...Note MAIN Unit Lot 10 11 22 FT 60R E Technical Supplement...
Page 25: ...Circuit Diagram MAIN Unit Lot 12 129 25 FT 60R E Technical Supplement...
Page 26: ...Note MAIN Unit Lot 12 129 26 FT 60R E Technical Supplement...
Page 29: ...Circuit Diagram MAIN Unit Lot 130 29 FT 60R E Technical Supplement...
Page 30: ...Note MAIN Unit Lot 130 30 FT 60R E Technical Supplement...
Page 55: ...13...