FT-450D CAT O
PERATION
R
EFERENCE
B
OOK
CAT
(C
OMPUTER
A
IDED
T
RANSCEIVER
)
O
PERATION
C
ONTROL
C
OMMAND
T
ABLES
P2
FUNCTION
00
MONI
Activates the Monitor function.
01
N/A
No Function.
02
P/B
Activates the Digital Voice Recorder.
03
PLAY1
Send the CW message, which is memorized in BEACON TEXT 1.
04
PLAY2
Send the CW message, which is memorized in BEACON TEXT 2.
05
PLAY3
Send the CW message, which is memorized in BEACON TEXT 3.
06
QSPL
Activates Quick Split Operation
07
SPOT
Generates a CW Spot Tone when using CW mode.
08
SQLOFF
Opens the noise squelch.
09
SWR
Transmits a 10 watts carrier (CW mode) to measure the SWR ratio.
10
TXW
Monitor the transmit frequency when Split Frequency operation is engaged.
11
VCC
Display the DC supply voltage.
12
VOICE2
Announces the current S-meter reading, operating frequency (with resolution to the displayed 100 Hz digit), and operating mode.
13
VM1MONI
Play back the voice message, which is memorized in Voice Memory 1.
14
VM1REC
Store the voice message into Voice Memory 1.
15
VM1TX
Send the voice message, which is memorized in Voice Memory 1.
16
VM2MONI
Play back the voice message, which is memorized in Voice Memory 2.
17
VM2REC
Store the voice message into Voice Memory 2.
18
VM2TX
Send the voice message, which is memorized in Voice Memory 2.
19
DOWN
Decreases the VFO frequency by one step or moves the memory channel to the next-lowest channel.
20
FAST
Set to the same function as the front panel’s [
FAST
] button.
21
UP
Increases the VFO frequency by one step or moves the memory channel to the next-highest channel.
22
DSP
Set to the same function as the front panel’s [
DSP
] button.
23
IPO/ATT
Set to the same function as the front panel’s [
IPO/ATT
] button.
24
NB
Set to the same function as the front panel’s [
NB
] button.
25
AGC
Set to the same function as the front panel’s [
AGC
] button.
26
MODEDN
Set to the same function as the front panel’s [
MODE
] button.
27
MODEUP
Set to the same function as the front panel’s [
MODE
] button.
28
DSP/SEL
Set to the same function as the front panel’s [
DSP/SEL
] button.
29
KEYER
Set to the same function as the front panel’s [
KEYER
] button.
30
CLAR
Set to the same function as the front panel’s [
CLAR
] button.
31
BANDDN
Set to the same function as the front panel’s [
BAND
] button.
32
BANDUP
Set to the same function as the front panel’s [
BAND
] button.
33
A=B
Set to the same function as the front panel’s [
A=B
] button.
34
A/B
Set to the same function as the front panel’s [
A/B
] button.
35
LOCK
Set to the same function as the front panel’s [
LOCK
] button.
36
TUNE
Set to the same function as the front panel’s [
TUNE
] button.
37
VOICE
Announce the current operating frequency (with resolution to the displayed 100 Hz digit) and operating mode.
38
MW
Copies the current operating data from the VFO into the currently selected memory channel.
39
V/M
Toggles frequency control between VFO and memory system.
40
HOME
Recall the “Home” (favorite frequency) channel.
41
RCL
Recall the QMB (Quick Memory Bank) memory.
42
VOX
Activate the VOX (automatic voice-actuated transmitter switching) feature.
43
STO
Copies operating data into QMB (Quick Memory Bank) Memory.
44
STEP
Enables the setting of the frequency step of the [
DSP/SEL
] knob by the [
DSP/SEL
] knob.
45
SPLIT
Activates split frequency operation between VFO-A and VFO-B.
46
PMS
Engages Programmable Memory Scan (PMS).
47
SCAN
Initiates the upward scanning of VFO frequencies or memory channels.
48
MENU
Engage the “Menu” mode.
49
DIMMER
Enables adjustment of the display dimmer level by the [
DSP/SEL
] knob.
50
MTR
Change the meter function in the transmit mode.
T
ABLE
6
00
01
02
03
04
05
06
07
08
67.0 Hz
69.3 Hz
71.9 Hz
74.4 Hz
77.0 Hz
79.7 Hz
82.5 Hz
85.4 Hz
88.5 Hz
09
10
11
12
13
14
15
16
17
91.5 Hz
94.8 Hz
97.4 Hz
100.0 Hz
103.5 Hz
107.2 Hz
110.9 Hz
114.8 Hz
118.8 Hz
123.0 Hz
127.3 Hz
131.8 Hz
136.5 Hz
141.3 Hz
146.2 Hz
151.4 Hz
156.7 Hz
159.8 Hz
27
28
29
30
31
32
33
34
35
162.2 Hz
165.5 Hz
167.9 Hz
171.3 Hz
173.8 Hz
177.3 Hz
179.9 Hz
183.5 Hz
186.2 Hz
36
37
38
39
40
41
42
43
44
189.9 Hz
192.8 Hz
196.6 Hz
199.5 Hz
203.5 Hz
206.5 Hz
210.7 Hz
218.1 Hz
225.7 Hz
45
46
47
48
49
---
---
---
---
229.1 Hz
233.6 Hz
241.8 Hz
250.3 Hz
254.1 Hz
---
---
---
---
CTCSS T
ONE
C
HART
18
19
20
21
22
23
24
25
26
T
ABLE
5
Page 8
T
ABLE
3
P2
000
010
030
040
050
060
070
080
090
100
FUNCTION
1.8 MHz “OFF”
3.5 MHz “OFF”
7 MHz “OFF”
10 MHz “OFF”
14 MHz “OFF”
18 MHz “OFF”
21 MHz “OFF”
24.5 MHz “OFF”
28 MHz “OFF”
50 MHz “OFF”
MY BAND
P2
001
011
031
041
051
061
071
081
091
101
FUNCTION
1.8 MHz “ON”
3.5 MHz “ON”
7 MHz “ON”
10 MHz “ON”
14 MHz “ON”
18 MHz “ON”
21 MHz “ON”
24.5 MHz “ON”
28 MHz “ON”
50 MHz “ON”
P2
10
20
30
40
50
60
70
80
90
A0
B0
C0
FUNCTION
LSB “OFF”
USB “OFF”
CW “OFF”
FM “OFF”
AM “OFF”
DATA (RTTY-LSB) “OFF”
CW-R “OFF”
USER-L “OFF”
DATA (RTTY-USB) “OFF”
N.A.
FM-N “OFF”
USER-U “OFF”
MY BAND
P2
11
21
31
41
51
61
71
81
91
A1
B1
C1
FUNCTION
LSB “ON”
USB “ON”
CW “ON”
FM “ON”
AM “ON”
DATA (RTTY-LSB) “ON”
CW-R “ON”
USER-L “ON”
DATA (RTTY-USB) “ON”
N.A.
FM-N “ON”
USER-U “ON”
T
ABLE
4