background image

 

 

External Connections 

Yacht Sentinel has an external connector that enables the connection of power and sensors. If 
you look at the External Connection Diagram on page 18, you will see how the connections are 
arranged when in standard mode. It is quite easy to add other sensors in place of those shown, 
such as pressure mats, tilt sensors, lanyards, etc.  to monitor a wide range of possible events.  
Likewise there are three external outputs one external temperature sensor and two ‘clean 
contact’ outputs for switching other devices. See page 19 for output wiring diagram. 
 
 

 
 
 
 
 
 
 
 
 
 

Figure 2 

 
 
LOCATING UNIT 

Install the unit on a flat surface with the top facing directly up to the sky to ensure the best 
connection with GPS satellites. If you need to ensure that the unit does not move around 
excessively, then please use either double-sided tape or Velcro to fix it to a surface. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3 

 
 

 

Summary of Contents for Yacht Sentinel

Page 1: ...1 USER MANUAL North America August 2014...

Page 2: ...Mounting 6 Infra Red Movement Sensor 7 Figure 5 Detection Zone 7 Internal Battery Connection 7 Figure 6a 6b Internal Battery Connection 7 Internal Power Connection 7 Installation Check List 8 Install...

Page 3: ...ring and security that can be customized to fit whatever your needs might be The unit is shipped pre programmed in its most popular user configuration to accommodate ease of installation with maximum...

Page 4: ...FUNCTIONS AND UNIT OVERVIEW Motion Sensor Use in enclosed area to detect motion Bilge 1 Used to detect a water level Can be bilge or high water monitor Bilge 2 Used to detect a water level Can be bil...

Page 5: ...ors lanyards etc to monitor a wide range of possible events Likewise there are three external outputs one external temperature sensor and two clean contact outputs for switching other devices See page...

Page 6: ...as shown in the External Input Connections Diagram The Hatch Sensors consist of one connected component and one free component The free component has an internal magnet that is detected by the connect...

Page 7: ...Sensor as shown below red wire screw connector 1 brown wire screw connector 2 black wire screw connector 3 INTERNAL BATTERY CONNECTION Please be aware that we send Yacht Sentinel with the internal bat...

Page 8: ...it This would also require disconnecting the internal battery All sensor wires can be extended if needed Make all splices with heat shrink connectors or tubing to protect them from elements Do not pla...

Page 9: ...ks If you now connect the Yacht Sentinel to the power supply the device enters a special charge phase in order to charge the battery During this phase the GSM and GPS are completely switched off and t...

Page 10: ...MOVEALARM OFF RADIUS 20 ANCHOR OFF SWING 20 Parameters Description SMS text Description YACHT Sentinel Device logo MY BOAT Name of the boat MMSI 68003836 The MMSI number set by the user default 00000...

Page 11: ...89dbm BOATBATT 11 7V VBATT 4 2V TEMP 25 GPSFIX YES TIME 11 26 35 DATE 31 05 12 LAT 52 06 4445N LONG 008 39 8726E SOG 33 COG 74 Status Description SMS text Description YACHT Sentinel Device logo MY BOA...

Page 12: ...d NEWPWD 8 After the user resets the password all masters will receive the following SMS as notification that the password is set to the default value PASSWORD RESET YACHT SENTINEL MY BOAT MMSI 680038...

Page 13: ...ed SHOREPOWER ALARM Indicates that the shore power has been removed BATT ALARM Indicates that the battery voltage is low MOVE OUT Indicates that the device has moved out of the set GPS geo fence posit...

Page 14: ...rameter description Note The tracking SMS will send to the person who initiated the tracking mode but not to the masters The device will try to resend the SMS to the destination every 30 seconds until...

Page 15: ...ht Sentinel sends MOVE IN to the masters RADIUS Command to set the permitted movement in meters if the move alarm is enabled 20 200 Note The permitted range is from 20m to 200m Since the Yacht Sentine...

Page 16: ...ll be sent in each SMS Default MY BOAT max 12 characters MMSI Command to set MMSI Maritime Mobile Service Identity max 12 characters NEWPWD Command to change the default password for SMS commands NEWP...

Page 17: ...d the following text to the Yacht Sentinel 4444 anchoralarm on swing 35 To change the password for SMS commands to 1111 send the following text to Yacht Sentinel 4444 newpwd 1111 To enable the trackin...

Page 18: ...ure 10 70 C GSM Integrated GSM module Telit GE865 Suitable for all networks frequencies GSM850 EGSM900 DCS1800 PCS1900 and providers UMTS not supported Usable with prepaid or contract SIM cards from a...

Page 19: ...ensors 100k ohm Hatch Sensor 10k ohm If other sensors types are used such as a pressure mat the tamper resistor must be placed across the input as in the above diagram otherwise the sensor will not be...

Page 20: ...an SMS to the YS 4444 status 7 Once this SMS is sent you will see the SMS being received by the YS as a series of quick flashes 8 The YS will then continue two or one flash if GPS has been detected e...

Page 21: ...has a closed circuit until activated mA mili amp Unit of electrical energy measurement V Volt MMSI Maritime Mobile Service Identity Nine digit system that uniquely identifies your vessel Definitions B...

Reviews: