QUICK START GUIDE

ba75977e05 07/2022

pHotoFlex

®

pH

LED FILTER PHOTOMETER WITH INTEGRATED pH FUNCTION

Summary of Contents for WTW pHotoFlex pH

Page 1: ...QUICK START GUIDE ba75977e05 07 2022 pHotoFlex pH LED FILTER PHOTOMETER WITH INTEGRATED pH FUNCTION...

Page 2: ...pHotoFlex pH 2 ba75977e05 07 2022 Copyright 2022 Xylem Analytics Germany GmbH Printed in Germany...

Page 3: ...hotometry 22 pH value ORP voltage 23 Disposal 24 Part of the process of consequently improving our products is the continuous further development of the range of photometric tests offered and the mete...

Page 4: ...is authorized see TECHNICAL DATA page 20 Any other use is considered unauthorized Display and socket field Display The graphic display shows all information of the current measurement in the measured...

Page 5: ...This section contains basic information on the operation of the pHotoFlex pH Measuring mode measured pa rameter Measured value with unit Program and citation form Diameter of the cell and measur ing...

Page 6: ...etry pH ORP Select the measured parameter within a measuring mode M short keystroke pH ORP pH ORP Photometry Concentration Absorbance Transmission Start calibration measuring mode pH ORP Start zero ad...

Page 7: ...ection is highlighted as white text on a black background Menus The name of the menu is displayed at the upper edge of the frame Menus are opened by confirming with START ENTER Example Switch the mete...

Page 8: ...ut by confirming with START ENTER Example display the Calibration record function in the pH ORP Calibration menu Messages Information or operating instructions are indicated by the i symbol They canno...

Page 9: ...fferent language as follows Setting the date and time The date and time are set in the menu Configuration System Continue Date time Operation Inserting a cell To be able to insert cells in the pHotoFl...

Page 10: ...rt the cell so that it is positioned on the bottom of the cell shaft The cell is ready to be measured 1 Put the fold out cell shaft 2 in an upright position until it locks into place 2 Pull up the hei...

Page 11: ...the M key long pressure repeatedly until the Photometry measuring mode is selected 2 Press the M key short pressure repeatedly until the measured parameter Concentration is selected Photometry Concent...

Page 12: ...ber display with PROG enter the required program number with the number keys and confirm with START ENTER or from the second concentration measurement Select a program out of the last ten programs wit...

Page 13: ...nual A table with the programs and required blank values can be found in the analysis specifications 1 Press the M key long pressure repeatedly until the Photometry measuring mode is selected 2 Press...

Page 14: ...ss the M key short pressure repeatedly until the measured parameter pH is selected pH ORP ORP 157mV 25 0 C AR 01 02 04 15 12 1 Press the M key long pressure repeatedly until the pH measuring mode is s...

Page 15: ...t set up for recycling purposes Batteries are marked with the crossed out waste container symbol There fore they may not be disposed with the domestic waste Cleaning Occasionally wipe the outside of t...

Page 16: ...ubstances If the content is released follow the danger warnings on the cell If necessary take corresponding protective measures protective goggles protective gloves etc 1 Switch the pHotoFlex pH off a...

Page 17: ...s Charge the rechargeable battery Cause Remedy Software error Operating condition undefined or EMC load unallowed Processor reset Press the START ENTER and PRT key simultaneously Cause Remedy Software...

Page 18: ...Clean the cell shaft Dilution set incorrectly Set the dilution Selected program unsuitable Select other program Zero measurement incorrect Perform zero measurement Blank value incorrect Remeasure the...

Page 19: ...Buffer solutions too old Use only once Note the shelf life Cause Remedy Cause Remedy pH electrode Junction contaminated Clean junction Membrane contaminated Clean membrane Test sample pH value not sta...

Page 20: ...e Follow special procedure Cause Remedy Cause Remedy Calibration interval expired Recalibrate the measuring system Dimensions approx 236 x 86 x 117 mm Weight approx 0 6 kg without batteries Mechanical...

Page 21: ...40 V 50 60 Hz 400 mA Output 9 V 1 5 A Connection max overvoltage category II Primary plugs contained in the scope of delivery Euro US UK and Australian Serial interface Connection of the cable AK 540...

Page 22: ...al may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct t...

Page 23: ...2 00 16 00 0 01 U mV 1000 1000 1 T C 5 0 100 0 0 1 T F 23 0 212 0 0 1 Manual temperature input Variable Range Increment Tmanual C 20 100 1 Accuracy 1 digit Variable Accuracy Temperature of the test s...

Page 24: ...ble reuse of material resources Waste from electrical and electronic equipment can be returned to the producer or distributor EU only Correct disposal of batteries in this product This marking on the...

Page 25: ......

Page 26: ...rove the way water is used conserved and re used in the future is central to our work Our products and services move treat analyze monitor and return water to the environment in public utility industr...