background image

6

ba15358d04

12/2021

F 800

Copyright

© 2021, Xylem Analytics Germany GmbH

Summary of Contents for wtw F 800 DIN

Page 1: ...BEDIENUNGSANLEITUNG OPERATING MANUAL MODE D EMPLOI INSTRUCCIONES DE OPERACI N ba15358d04 12 2021 F 800 DIN F 800 BNC...

Page 2: ...2 ba15358d04 12 2021 F 800 Copyright 2021 Xylem Analytics Germany GmbH...

Page 3: ...bration measurement 18 Sample preparation 19 Response times 19 Interferences 19 Aging 20 Maintenance 20 Storage 20 Recommended accessories 21 Calibration line of a fluoride sensitive electrode 22 What...

Page 4: ...r calibrar medir 38 Preparativos para la muestra 39 Tiempo de reacci n 39 Trastornos 40 Envejecimiento 40 Mantenimiento 40 Almacenamiento 41 Accesorios recomendados 41 Curva de calibraci n de un elect...

Page 5: ...BEDIENUNGSANLEITUNG ba15358d04 12 2021 F 800 DIN F 800 BNC FLUORID SELEKTIVE ELEKTRODE BEDIENUNGSANLEITUNG...

Page 6: ...6 ba15358d04 12 2021 F 800 Copyright 2021 Xylem Analytics Germany GmbH...

Page 7: ...O Ring 6 Einf ll ffnung f r den Br ckenelektrolyt 7 Innere Diaphragmen 8 Schliffdiaphragma 9 Aufbewahrungsk cher f r F 800 9 7 8 4 6 5 3 2 1 1 Aufbewahrungsk cher abziehen 2 Br ckenelektrolyt ELY BR...

Page 8: ...lyt befinden eine optimale Eintauchtiefe gegeben ist Vor dem Messen 4 Dabei ausgelaufenen Br ckenelektrolyt nachf llen so dass die inne ren Diaphragmen mit Br ckenelektrolyt bedeckt sind 5 Einstabmess...

Page 9: ...Standardl sung nahe an der zu erwartenden Konzent ration in der Messl sung liegen Die Konditionierzeit h ngt von der Vorgeschichte der ionenselektiven Elektrode ab Bei Inbetriebnahme und nach l ngere...

Page 10: ...ktrode folgende T tigkeiten ausf h ren Bei organischen Bel gen die Membran mit Isopropanol und weichem Papiertuch reinigen Anschlie end die Elektrode erneut konditionieren siehe Abschnitt KONDITIONIER...

Page 11: ...ckenelektrolyt ber die Einf ll ffnung einf llen L nger als ber Nacht Den Br ckenelektrolyt entfernen und die Einstabmesskette mit entioni siertem Wasser sp len mit einem sauberen Papiertuch trocken tu...

Page 12: ...Br ckenelektrolyt benetzt Br ckenelektrolyt nachf llen bis die inneren Diaphragmen mit Br ckenelektrolyt bedeckt sind Innere Diaphragmen verkrustet Br ckenelektrolyt einige Stunden auf innere Diaphra...

Page 13: ...sf hrung Innere Diaphragmen verkrustet Br ckenelektrolyt einige Stunden auf innere Diaphragmen einwirken lassen bis die Kruste aufgel st ist Messkette bzw Elektrode defekt Messkette bzw Elektrode aust...

Page 14: ...14 ba15358d04 12 2021 Technische Daten F 800...

Page 15: ...OPERATING MANUAL ba15358d04 12 2021 F 800 DIN F 800 BNC FLUORIDE SENSITIVE ELECTRODE OPERATING MANUAL...

Page 16: ...16 ba15358d04 12 2021 F 800 Copyright 2021 Xylem Analytics Germany GmbH...

Page 17: ...ut 5 O ring 6 Filling opening for bridge electrolyte 7 Inner junctions 8 Ground junction 9 Storage vessel for F 800 9 7 8 4 6 5 3 2 1 1 Remove the storage vessel 2 Fill the bridge electrolyte ELY BR 5...

Page 18: ...he depth of immersion is within the optimum range Before measuring 4 When doing so refill any spilled bridge electrolyte so that the inner junctions are covered with bridge electrolyte 5 Rinse the com...

Page 19: ...itive electrode To achieve a good responding behavior the concentration of the standard solution should be similar to the concentration expected of the test sample During commissioning and after long...

Page 20: ...tivities In the case of organic coatings clean the membrane with isopropanol and a soft paper towel Then recondition the electrode see section CONDITIONING CALIBRATION MEASUREMENT Clean the inside of...

Page 21: ...new bridge electrolyte into the filling opening Longer than over night Remove the bridge electrolyte then rinse the combination electrode with deionized water and dab it dry with a clean paper towel S...

Page 22: ...d with bridge electrolyte Fill up bridge electrolyte until the inner junctions are covered with bridge electrolyte Inner junctions encrusted Leave the bridge electrolyte to react on the inner junction...

Page 23: ...g on the design Inner junctions encrusted Leave the bridge electrolyte to react on the inner junctions for some hours until the crusts have dissolved Electrode defective Exchange the electrode Cause R...

Page 24: ...24 ba15358d04 12 2021 Technical data F 800...

Page 25: ...MODE D EMPLOI ba15358f04 12 2021 F 800 DIN F 800 BNC ELECTRODE S LECTIVE DE FLUORURE MODE D EMPLOI...

Page 26: ...26 ba15358f04 12 2021 F 800 Copyright 2021 Xylem Analytics Germany GmbH...

Page 27: ...ique d tanch it 6 Orifice de remplissage pour l lectrolyte pont 7 Diaphragmes int rieurs 8 Diaphragme rod 9 tui de conservation pour F 800 9 7 8 4 6 5 3 2 1 1 Retirer l tui de conservation 2 Remplir d...

Page 28: ...mmersion optimale soit donn e Avant la mesure 4 Ce faisant faire l appoint pour compenser l lectrolyte pont coul de sorte que les diaphragmes int rieurs soient couverts d lectro lyte pont 5 Rincer la...

Page 29: ...alon devrait tre proche de la concentration atten due dans la solution de mesure Le temps de conditionne ment d pend des ant c dents de l lectrode s lective d ions Pendant la mise en service et apr s...

Page 30: ...de mesure une tige Faire l appoint d lectrolyte pont consomm En cas de temps de r action de l lectrode plus lev s ex cuter les op rations suivantes En cas de d p ts organiques nettoyer la membrane ave...

Page 31: ...te de raccordement et laisser l lectrolyte pont s couler Ensuite remplir d lectrolyte pont frais par l orifice de remplissage Pour plus d une nuit Enlever l lectrolyte pont et rincer la cha ne de mes...

Page 32: ...nt rieurs pas assez mouill s d lectrolyte pont Faire l appoint d lectrolyte pont jusqu ce que les diaphragmes int rieurs soient couverts d lectrolyte pont Diaphragmes int rieurs encro t s Laisser l le...

Page 33: ...ions talons trop vieilles Utiliser de nouvelles solutions talons Diaphragmes int rieurs encro t s Laisser l lectrolyte pont agir quelques heures sur les diaphragmes int rieurs jusqu ce que la cro te s...

Page 34: ...34 ba15358f04 12 2021 Caract ristiques techniques F 800...

Page 35: ...MANUAL DE INSTRUCCIONES ba15358s04 12 2021 F 800 DIN F 800 BNC ELECTRODO ION SELECTIVO PARA FLUORURO MANUAL DE...

Page 36: ...36 ba15358s04 12 2021 F 800 Copyright 2021 Xylem Analytics Germany GmbH...

Page 37: ...llenado para el electrolito puente 7 Diafragmas interiores 8 Diafragma esmerilado 9 Carcaj de protecci n para almacenamiento para F 800 9 7 8 4 6 5 3 2 1 1 Quitar el carcaj de protecci n para almacen...

Page 38: ...est dada Antes de medir 4 Rellenar el electrolito puente derramado de modo que los diafrag mas interiores queden cubiertos de electrolito puente 5 Enjuagar la cadena de medici n de una vara con agua d...

Page 39: ...te a la concentraci n prevista de la soluci n de medici n El tiempo requerido para el acondicionamiento depende del historial precedente del electrodo ion selectivo Durante la puesta en funcionamiento...

Page 40: ...una vara Rellenar el electrolito puente consumido Si el tiempo de reacci n del electrodo aumenta demasiado proceder como se indica a continuaci n Si se tiene depositaciones org nicas en las membranas...

Page 41: ...el cabezal de conexi n y dejar escurrir el electrolito puente A continuaci n llenar electrolito puente nuevo a trav s de la abertura de llenado Por un per odo m s prolongado m s de una noche Eliminar...

Page 42: ...st n suficientemente mojados con el electrolito puente rellenar electrolito puente hasta que los diafragmas interiores est n completamente cubiertos diafragmas interiores con incrustaciones dejar actu...

Page 43: ...uy vieja utilizar una soluciones patr n nueva diafragmas interiores con incrustaciones dejar actuar el electrolito puente durante algunas horas sobre los diafragmas interiores hasta que las incrustaci...

Page 44: ...44 ba15358s04 12 2021 Especificaciones t cnicas F 800...

Page 45: ......

Page 46: ...rove the way water is used conserved and re used in the future is central to our work Our products and services move treat analyze monitor and return water to the environment in public utility industr...

Reviews: