Xylem rule DB412 Instruction Manual Download Page 5

•  A seacock installed in accordance with the requirements of ABYC H-27, 

Seacocks, Thru-Hull Connections, and Drain Plugs, and

•  A vented loop to prevent siphoning into the boat. A check valve shall 

not be used for this purpose.

If the discharges of several pumps are manifolded to discharge through a 
single thru-hull fitting, the system shall be designed so that the operation 
of one pump will not back feed another pump, and the simultaneous 
operation of each pump will not diminish the pumping capacity of the 
system. A check valve shall not be used in the discharge manifold system.
During the winterization of a vessel, it’s recommended that you remove 
the check valve and drain any residual water from the plumbing.
Periodically remove, clean and inspect bilge pump, check valve and its 
surroundings for damage or debris that may reduce the performance of 
the pump.

Operation

The dc motor is suitable for intermittent duty and should not be run for 
more than 30 minutes continuously.

Rotation of Pump Head

1. Push down on clip and remove end cover
2. Internal bolt heads now exposed
3. Undo all four mounting bolts
4. Remove bolts and grasp motor unit firmly
5. Rotate pump head to desired position
6. Example of pumps rotational capabilities
7. Replace all 4 internal bolts and secure tightly
8. Replace end cover

1

3

5

7

2

4

6

8

All mounting holes must be sealed with a marine 

grade sealant to prevent water intrusion.

Install to ABYC H-22 and E-11

Summary of Contents for rule DB412

Page 1: ...DRY BILGE PUMP WITH PANEL SWITCH DB412 INSTRUCTION MANUAL...

Page 2: ...ine fuel source as described in ABYC E 11 5 3 3 Exception 1 Boats using diesel fuel as the only fuel source 2 Outboard engines mounted externally or in compartments open to the atmosphere in accordanc...

Page 3: ...ded to absorb vibration Use 3 4 19mm i d spiral reinforced hose with a smooth internal bore or semi rigid pipework systems Connect the hose to inlet and outlet of pump using stainless steel hose clamp...

Page 4: ...charge piping longer runs reduce flow The number or radius of bends Excess amount of debris in water A strainer or other means of preventing debris from entering the pump inlet should be used to prolo...

Page 5: ...s recommended that you remove the check valve and drain any residual water from the plumbing Periodically remove clean and inspect bilge pump check valve and its surroundings for damage or debris that...

Page 6: ...ten until firmly secure Maintenance Check all electrical connections periodically particularly in salt water areas Corrosion can cause loss of performance or non operation in extreme cases The motor s...

Page 7: ...mbly 13 Shower Drain Bilge Pump Chamber 17 Washer Bilge Pump Service Kit 7 Cover 1 8 Diaphragm 1 10 Hex Head Screw 4 12 Screw Recessed Pan Head 1 14 Shower Drain Bilge Pump Joker Valve 2 15 Shower Dra...

Page 8: ...onditions of sale copies of which will be furnished upon request 2020 Xylem All rights reserved Rule is a trademark of Xylem or one of its subsidiaries 950 0548 Rev B 05 2020 USA 100 Cummings Center S...

Reviews: