![Xylem Lowara Scuba Additional Installation, Operation And Maintenance Instructions Download Page 29](http://html.mh-extra.com/html/xylem/lowara-scuba/lowara-scuba_additional-installation-operation-and-maintenance-instructions_892236029.webp)
en – Original instructions
SCUBA – Additional Installation, Operation and Maintenance Instructions
29
60 Hz
Model
Head, m (ft)
Model
Head, m (ft)
Model
Head, m (ft)
1SC4/05/6C
58 (191)
5SC4/15/6C
69 (226)
3SC6/15/6T
100 (328)
1SC5/07/6C
73 (238)
8SC2/11/6C
32 (103)
5SC2/07/6T
35 (115)
1SC6/11/6C
86 (283)
8SC3/15/6C
47 (155)
5SC3/11/6T
52 (172)
3SC2/05/6C
33 (107)
1SC3/05/6T
45 (147)
5SC4/15/6T
68 (223)
3SC3/07/6C
49 (161)
1SC4/07/6T
60 (196)
5SC6/22/6T
102 (335)
3SC4/09/6C
65 (214)
1SC5/09/6T
75 (244)
8SC2/11/6T
32 (104)
3SC5/11/6C
82 (268)
1SC6/11/6T
89 (293)
8SC3/15/6T
48 (156)
3SC6/15/6C
98 (321)
3SC2/05/6T
34 (110)
8SC4/22/6T
63 (208)
5SC2/07/6C
34 (112)
3SC3/07/6T
50 (165)
-
-
5SC3/11/6C
51 (167)
3SC4/09/6T
67 (219)
-
-
8.3
Maximum operating pressure
1MPa (145 psi).
Note:
P1max + Pmax ≤ PN.
Data
Description
P1max
Maximum input pressure
Pmax
Maximum pressure generated by the unit
PN
Maximum operating pressure
8.4
Maximum number of starts per hour
Motor power, kW
Starts / h
0.5 - 0.9
25
1.1 - 2.2
20
8.5
Mechanical characteristics
Electric power supply cord length
20 m (66 ft).
Maximum immersion depth
17 m (56 ft)
Protection class
IPX8.
8.6
Electrical specifications
Speed
Frequency Hz
Speed, min
-1
50
2900
60
3500