General fault finding guide

Lowara UK Limited

Millwey Rise Industrial Estate,  Axminster, Devon  EX13 5HU - UK     
Tel:  01297 630230     Fax: 01297 630270
e-mail: [email protected]    
http://www.lowara.co.uk           http://completewatersystems.com

Lowara is a trademark of Xylem Inc. or one of its subsidiaries.      © 2011 Xylem, Inc.
Lowara reserve the right to make modifications without prior notice.    
cod. UKLIT0091 P05/12

Fault

Possible Cause

Remedy

Pump fails to start

Power supply failure

Reinstate incoming power supply 

Genyo has no lights on

Isolator fuse blown/MCB tripped

Replace fuse/reset MCB

Pump fails to stop

User point left open causing flow
to take place 
Leak in system

Close user point 

Switch unit off until leak is repaired

Pump switches on and off
quickly

Air in system
Vessel pre-charge (if fitted) 
incorrect
Dribble condition at outlet

Purge air from pumps and pipework
Check vessel pre-charge and Charge as
necessary with Nitrogen or dry air
Replace/repair outlet

Pump runs but will not
make pressure

Pump air locked
Commissioning valve left open
Passing too much water

Vent pump
Check commissioning valves are in 
correct position.
Check system for leaks

Pump overheating

Pump partially seized

Remove pump and check for sediment
build up or foreign objects

Break tank overflowing

Leaking ball valve
Non-return valve letting by

Replace ball valve seal
Replace/clean non-return valve in Genyo

Pump stops and pressure
drops immediately

Non-return valve letting by
Vessel pre-charge incorrect

Replace non-return valve in Genyo unit
Check as necessary with Nitrogen or dry
air