Xylem Lowara Micro PRESFIX Operating, Installation And Maintenance Instructions Download Page 6

Fault

Possible Cause

Remedy

Pump fails to start.

Power supply failure.

Control panel fuse blown. 

Low water level.

Reinstate incoming power supply. 

Replace power supply fuse. 

Reinstate water supply.

Pump fails to stop.

Set point set too high.

Air in system.

System pressure low due to 
large leak.

Lower set point.

Bleed pumps.

Switch unit off until leak is repaired.

Pump switches on and off
quickly.

Air in system.

Unit isolated from system 
vessel or pre-charge incorrect.

Purge air from pumps and pipework.

Check vessel and system isolating valves are in the 
open position and check vessel pre-charge.
Charge as necessary with Nitrogen or dry air.

Pump runs but will not
make pressure.

Pump air locked.

Large leak in system

Passing too much water.

Open bleed screw in system and vent.

Check system for leaks.

Check pump Non return valve.

Pump overheating.

Pump partially seized.

Remove pump and check for sediment build up or 
foreign objects

Pump set frequently
starting. (pressure falls
to cut in point).

Newly installed system with large

amount of air in pipe work.

Leaks in system pipe work.

Vessel pre-charge incorrect.

Bleed system to remove air.

Repair leaks.

Isolate vessel and pre-charge with 
Nitrogen as appropriate.

Break tank overflowing.

Non-return valve letting by.

Replace pump or non-return valve in pump. 

Pump stops and
pressure drops
immediately.

Non-return valve letting by.

Vessel pre-charge incorrect.

Replace pump or non-return valve in pump.

Check vessel pre-charge and Charge as
necessary with Nitrogen or dry air.

Fault finding guide

Xylem Water Solutions UK Limited

Millwey Rise Industrial Estate,  Axminster, Devon  EX13 5HU - UK     
Tel:  01297 630230     Fax: 01297 630270
e-mail: [email protected]    
www.lowara.co.uk       www.xyleminc.com

Lowara is a trademark of Xylem Inc. or one of its subsidiaries.      
© 2017 Xylem, Inc.

Lowara reserve the right to make modifications without prior notice. 

Code UKLIT0167          P03/17

O&M Micro Presfix_Layout 1  29/03/2017  11:15  Page 6

Summary of Contents for Lowara Micro PRESFIX

Page 1: ...all persons responsible for the installation operation and maintenance of this product Warning Symbols Safety instructions where noncompliance would affect safety Safety instructions where electrical hazard is involved Safety instructions where noncompliance could cause damage to the equipment Instruction for safe use This product has been designed for the pressurisation of sealed heating chilled ...

Page 2: ...n sketch Fig 1 The Break tank is constructed to have a weir slot as required by the water bylaws to prevent back flow contamination if the inlet ball valve or NRV suffered a catastrophic failure the overflow may not be able to keep up with the inflow in which case excess water will be ejected through the weir slot in the side of the case and onto the plant room floor if this is not acceptable then...

Page 3: ...position no pumps are allowed to run but low and high pressures are still monitored In hand pump 1 or 2 press the select button and the selected pump will run for 10 seconds and then switch to off Auto will need to be selected after this operation To lock the selected data put the switch on the back of the display to the locked position Set point description Delay start This set point is adjustabl...

Page 4: ... 0 28 days and is used to run the pumps for a short period after the set time has elapsed running the pumps at regular intervals helps prevent pumps from seizing due to inactivity V Free contacts See appropriate drawing for Volt free contact availability Rating 1A 50v maximum Features Hours Run With the mode switch scroll through until P1 hours run is shown or P2 and the run hours will be displaye...

Page 5: ...n its own Maintenance Routine check 3 monthly intervals 1 Check that the pump seal is not leaking 2 Check the pump is not seized and develops the correct pressure 3 Check that the pump operates without undue noise or vibration Routine check 6 monthly intervals 1 Check the break tank is clean and that the correct water level has been maintained 2 Check that all screws are tight on electrical compon...

Page 6: ... and check for sediment build up or foreign objects Pump set frequently starting pressure falls to cut in point Newly installed system with large amount of air in pipe work Leaks in system pipe work Vessel pre charge incorrect Bleed system to remove air Repair leaks Isolate vessel and pre charge with Nitrogen as appropriate Break tank overflowing Non return valve letting by Replace pump or non ret...

Reviews: