7.0 PRODUCT OPERATION

7. 1 OPERATING CONDITIONS

-   Maximum ambient temperature is +60 deg. C 

(140 deg. F), with minimum temperature - 
15 deg. C (5 deg. F).

-   The life of the impeller depends upon the 

temperature of the liquid being pumped.

-   High and low temperatures can affect impeller 

life.

7.2 PERMITTED FLUIDS:

-   Only use the pump with specified products, 

including fresh and salt water solutions.

-  Do not use any Jabsco pump for petrol,  

petroleum products or any products with  
a flash point below 37 deg. C, (98 deg. F),  
explosion or death may occur, shown below.

-   If in doubt about pump material compatibly, 

consult the website or a sales representative.

-   If in doubt about the use of the pump in a 

potentially explosive atmosphere, consult the 
website or a sales representative.   

-   If corrosive products are pumped, pump life will 

be prolonged if pump is flushed with water at the 
end of each cycle.

7.3 INITIAL START-UP:

-  Complete the installation (as per section 5).
-  This is a continuously rated pump for 

recommended duty cycle of 30 minutes. 

-  The pump is self-priming to 1.2 m (4 ft).  
-  Intake lines must be air-tight to ensure self-

priming.

-  The pump will run dry up to 1 off for 5 minutes.
-  Priming may take up to 35 seconds, if priming 

takes longer than the designated time, check: 

-  There are no blockages in the suction hose, 
-  The inlet filter is not blocked,
-  The suction pipework is airtight,
-  The height you are priming to falls within the 

priming capabilities listed in section 7.

- Do not operate any switches with wet hands.
- Never operate a motor which in any way has been 

manipulated and lost its full enclose.

WARNING!
The working temperature of the motor may 

reach a maximum of approx. +80 deg. C (surface 
temperature) which may burn your skin.

-  Motors can spark and explosion and death can 

occur, with incorrect wiring causing injury or 
death.

7.4 STORAGE AND CLEANING

-  If any pump unit needs to be removed for 

storage purposes, it must be stored in a cool dry 
location

-  Pump units are rated to IP55. It is recommended 

that the unit is wiped down after use.

-  Liquids must not be allowed to freeze in 

the pump body, to winterise your system all 
water must be drained from the entire system, 
including the pump.

8.0 TECHNICAL SPECIFICATIONS

-  The data specified in the above table refers 

to performance running at the ideal efficiency 
points on water at 20 deg. C. with fully charged 
battery (12.8v).

-  The ‘MAX AMP DRAW’ refers to the pumps 

running at their maximum pressure, which is past 
their recommended duty point.

- For longer installations, fit thicker cables 

(reference ISO 10133).

-  The wire length is the total distance from the 

battery to the pump and back to the battery.  It is 
recommended to use a relay to shorten the main 
leaders.

-  If the fuse fails repeatedly, do not fit a heavier 

fuse or bridge the fuse terminals with silver 
paper or metal wire.  Failure to observe this 
instruction may result in a fire hazard due to 
overheating of cables.

-  Exceeding recommended pump discharge 

pressure will shorten the impeller life.

Total Head 

(DIFF)

Flow

Current

M

FT

LPM

US GPM

AMPS

0

0

60

16

14

2

7

56

14.8

14.5

4

13

50

13.2

15

6

20

42

11.4

16

8

26

32

8.5

17

10

33

18

4.7

18

12

39

5

1.6

19

Model 

Number

Voltage 

(V DC)

Maximum 

AMP Draw 

(A)

Minimum 

Fuse Size 

(A)

Minimum 

Wire Size 

(mm2)

Maximum 

Total Length 

Between (+) 

& (-) Battery 

Terminals

22610-9007

12.8

19

25

 8

4.5

22610-2007

12.8

19

25

 8

4.5

Summary of Contents for Jabsco Ballast King 22610-2007

Page 1: ...Ballast King DC Flexible Impeller Pump ...

Page 2: ......

Page 3: ...ectrical Configuration 5 4 Footprint Specifications 6 0 Environmental Protection 7 0 Product Operation 7 1 Operating Conditions 7 2 Permitted Fluids 7 3 Initial Start Up 7 4 Storage and Cleaning 8 0 Technical Specifications 9 0 Maintenance Service and Customer Repair 10 0 Customer Support 11 0 Parts and Accessories 12 0 EC Declaration of Conformity Ballast King DC Flexible Impeller Pump 3 ...

Page 4: ...r safe operation when used as detailed in accordance with the Manufacturer s instructions This manual also contains necessary information for the correct installation This manual was developed for qualified personnel with suitable training and technical qualification to operate this type of equipment NOTE Failure to use this equipment in accordance with the manufacturer s operating instructions ma...

Page 5: ... spiral reinforced hose with a smooth internal bore that will not collapse under suction or rigid or semi rigid pipework systems The pump can be mounted on any flat suitable surface Fit the pump in a dry well ventilated position where there is full access for service Use rubber grommets provided to minimise vibration do not over tighten the mounting screws All marine pumps discharging overboard mu...

Page 6: ...rce see section 8 for recommended fuses Ensure fuses for the Ballast King pump are slow burning being capable of handling the start up and reversing current Connect the black motor wire to the negative battery terminal Inadequate voltage at the motor terminals when the pump is running not less than 95 below rated voltage at full load due to partially discharged batteries or insufficient cable size...

Page 7: ...number is RM07081 Full details of scheme can be found Valpak Limited Unit 4 Montague House Stratford upon Avon Business and Technology Park Banbury Road Stratford upon Avon Warwickshire CV37 7GW At the end of your product and accessories life it must not be discarded as domestic waste Please contact your distributor supplier for further information For end users outside of the EU consult applicabl...

Page 8: ... full enclose WARNING The working temperature of the motor may reach a maximum of approx 80 deg C surface temperature which may burn your skin Motors can spark and explosion and death can occur with incorrect wiring causing injury or death 7 4 STORAGE AND CLEANING If any pump unit needs to be removed for storage purposes it must be stored in a cool dry location Pump units are rated to IP55 It is r...

Page 9: ... be returned please ensure the pump unit has been fully drained Please contact customer services for more information No used pumps parts will be accepted as returns unless complete details of liquids pumped are supplied Item Number Quantity Part Number 1 1 23094 9000 2000 2 1 98012 9334 3 1 9328 0200 4 2 X3001 147F 5 1 23095 0107 6 1 23005 2529 2530 7 1 SP2701 52 8 4 92900 0380 9 1 X5251 049 10 3...

Page 10: ...me navigation and radio communication equipment and systems General requirements 2002 ELVD BS EN ISO 10133 Small craft Electrical systems Extra Low Voltage d c systems dc installations 2012 ISO ISO 8846 Small craft Electrical devices Protection against ignition of surrounding flammable gases 1990 ENV EN 60068 2 1 Cold 2007 EN 60068 2 2 Hot 2007 EN 60068 2 6 Vibration General 2008 Vibration Resonan...

Page 11: ......

Page 12: ... environment and we help people use water efficiently in their homes buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of innovation For more information on how Xylem can help you go to www xyleminc com UNITED STATES SA We...

Reviews: