7.0 PRODUCT OPERATION
7. 1 OPERATING CONDITIONS
- Maximum ambient temperature is +60 deg. C
(140 deg. F), with minimum temperature -
15 deg. C (5 deg. F).
- The life of the impeller depends upon the
temperature of the liquid being pumped.
- High and low temperatures can affect impeller
life.
7.2 PERMITTED FLUIDS:
- Only use the pump with specified products,
including fresh and salt water solutions.
- Do not use any Jabsco pump for petrol,
petroleum products or any products with
a flash point below 37 deg. C, (98 deg. F),
explosion or death may occur, shown below.
- If in doubt about pump material compatibly,
consult the website or a sales representative.
- If in doubt about the use of the pump in a
potentially explosive atmosphere, consult the
website or a sales representative.
- If corrosive products are pumped, pump life will
be prolonged if pump is flushed with water at the
end of each cycle.
7.3 INITIAL START-UP:
- Complete the installation (as per section 5).
- This is a continuously rated pump for
recommended duty cycle of 30 minutes.
- The pump is self-priming to 1.2 m (4 ft).
- Intake lines must be air-tight to ensure self-
priming.
- The pump will run dry up to 1 off for 5 minutes.
- Priming may take up to 35 seconds, if priming
takes longer than the designated time, check:
- There are no blockages in the suction hose,
- The inlet filter is not blocked,
- The suction pipework is airtight,
- The height you are priming to falls within the
priming capabilities listed in section 7.
- Do not operate any switches with wet hands.
- Never operate a motor which in any way has been
manipulated and lost its full enclose.
WARNING!
The working temperature of the motor may
reach a maximum of approx. +80 deg. C (surface
temperature) which may burn your skin.
- Motors can spark and explosion and death can
occur, with incorrect wiring causing injury or
death.
7.4 STORAGE AND CLEANING
- If any pump unit needs to be removed for
storage purposes, it must be stored in a cool dry
location
- Pump units are rated to IP55. It is recommended
that the unit is wiped down after use.
- Liquids must not be allowed to freeze in
the pump body, to winterise your system all
water must be drained from the entire system,
including the pump.
8.0 TECHNICAL SPECIFICATIONS
- The data specified in the above table refers
to performance running at the ideal efficiency
points on water at 20 deg. C. with fully charged
battery (12.8v).
- The ‘MAX AMP DRAW’ refers to the pumps
running at their maximum pressure, which is past
their recommended duty point.
- For longer installations, fit thicker cables
(reference ISO 10133).
- The wire length is the total distance from the
battery to the pump and back to the battery. It is
recommended to use a relay to shorten the main
leaders.
- If the fuse fails repeatedly, do not fit a heavier
fuse or bridge the fuse terminals with silver
paper or metal wire. Failure to observe this
instruction may result in a fire hazard due to
overheating of cables.
- Exceeding recommended pump discharge
pressure will shorten the impeller life.
Total Head
(DIFF)
Flow
Current
M
FT
LPM
US GPM
AMPS
0
0
60
16
14
2
7
56
14.8
14.5
4
13
50
13.2
15
6
20
42
11.4
16
8
26
32
8.5
17
10
33
18
4.7
18
12
39
5
1.6
19
Model
Number
Voltage
(V DC)
Maximum
AMP Draw
(A)
Minimum
Fuse Size
(A)
Minimum
Wire Size
(mm2)
Maximum
Total Length
Between (+)
& (-) Battery
Terminals
22610-9007
12.8
19
25
8
4.5
22610-2007
12.8
19
25
8
4.5