4
ASSEMBLY
1.
Lubricate seal with water and position it in seal bore with lip, or hollowed-out side of seal, pointing towards the impeller bore. With a 1/2” diameter
dowel, push against the shaft seal into its bore until it contacts the bottom.
2.
Lubricate motor shaft and install body on motor.
3.
Lubricate impeller bore and, aligning flat in impeller with flat on motor shaft, install impeller with clockwise rotary motion.
4.
Install O-ring, end cover and screws.
Dimensional Drawing
Inches (Millimeters)
Dessin dimensionnel en pouces (millimètres) / Maßzeichnung Zoll (Millimeter) / Disegno dimensionale Pollici (millimetri)
Maattekening inch (millimeter) / Måttritning tum (millimeter) / Dibujo dimensional en pulgadas (milímetros)
B
A
J
O
C
S
7-1/8
(181)
2
(51)
1-7/8
(48)
3-5/8
(93)
3/8
(10)
3-1/2
(89)
4-5/32
(105)
4-3/4
(121)
DISCHARGE
2-3/8
(60)
2X 1/2-14 NPT
(Female)
WARRANTY
XYLEM LIMITED WARRANTY WARRANTS THIS PRODUCT TO BE FREE OF DEFECTS AND WORKMANSHIP FOR A PERIOD OF 1 YEAR. THE WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY AND ALL OTHER EX-
PRESS OR IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF WHATEVER NATURE RELATING TO THE GOODS PROVIDED HEREUNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXPRESSLY DISCLAIMED AND EXCLUDED. EXCEPT AS OTHERWISE PROVIDED BY LAW, BUYER’S
EXCLUSIVE REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF ANY OF THE FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES
BE LIMITED TO THE AMOUNT PAID BY THE BUYER HEREUNDER. IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CON-
SEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF BUSINESS,
LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION. THIS WARRANTY IS ONLY A REPRESENTATION OF THE COMPLETE LIMITED WARRANTY. FOR A DETAILED EXPLANATION,
PLEASE VISIT US AT www.xylem.com/en-us/support/, CALL OUR OFFICE NUMBER LISTED, OR WRITE A LETTER TO YOUR REGIONAL OFFICE.
RETURN PROCEDURE
Warranty returns are conducted through the place of purchase. Please contact the appropriate entity with a receipt of purchase to verify date.
AIS (Aquatic Invasive Species) Decontamination Process.
All of our pumps are designed to meet the ABYC standards for the current AIS
Decontamination procedure including low pressure water at 120ºF for 130 seconds.
Please follow current guidelines for the decontamination process.