Figure 2: Drainage opening
Pumps with motors above 5 HP require extra support.
4.1.8 Tanks under pressure
For applications where the tank is going to be under pressure install the plug in the drainage
on page 17.
4.1.9 Positioning measurements
A
B
C
D
≥ 5.9 in
(150 mm)
≥ 7.9 in
(200 mm)
RS002025
Dimensions are in in (mm).
Model
A
B
C
D
1, 3 and 5
0.79 (20)
Dimension depends on the configuration
used. See the Technical Brochure for
more information.
Minimum 1.18 (30)
1
10, 15 and 22
1.38 (35)
4.1.10 Install the unit
1. Install the gasket.
2. Remove the discharge port plug.
1
Dimension D has to be established based on the clearance needed to extract the pump.
4 Installation
e-SVI series Instruction Manual
17