Xylem GOULDS 4SPC10EC Instruction Manual Download Page 4

PRIMING cont. 

flow  does  not  start  within  five  minutes,  stop  motor  and 

determine cause (see Trouble Guide on back page).  Be sure 

all suction and discharge valves are open when the pump is 

running.  Operating  the  pump  with a  closed  valve  in  the 

system can cause pump damage. 

MAINTENANCE 

The  strainer  built  into  the  pump  should  be  inspected  and 

cleaned daily. These strainers are easy to clean.  Loosen the 

hand  knob(s)  and  remove  the  strainer  cover  to  expose  the 

strainer  basket.  Remove  the  basket  and  clean.  Inspect  the 

cover gasket;  if damaged,  replace.  Install the strainer cover, 

tightening hand knob by hand only.  The pump seal  requires 

no  lubrication.  The  electric  motor  has  bearings  and  you 

should refer  to  the motor manufacturer's  instructions  for 

proper maintenance. 

STORAGE 

If  your  pool is  deactivated  until  next season,  care  must  be 

taken to  protect  the  pump-motor  from  damage  and  ex­

posure.  Over  the  winter,  store  the  pump-motor  unit  in  a 

warm, dry location. 

NOTE: 

Be  certain  power  is  turned  off  at  the  control  panel. 

Next  drain  the  casing  by  removal of  both  drain  plugs. 

Disconnect the suction  and  discharge lines at  the union 

connections, then move unit to warm, dry indoor location. 

SAFETY INSTRUCTIONS 

When installing and  using  this  electrical equipment,  basic 

safety precautions should always be followed, including the 

following: 

REPLACEMENT PARTS 

This  unit is  designed  to  provide  maximum electrical safety. 

To  assure  continued  protection  against  shock  hazard  use 

only  identical  factory  supplied  replacement  parts  when 

servicing. 

CAUTION

.. The  performance of  Marlow  pumps  is based upon 

clear,  cold,  fresh  water  with suction conditions as shown 

on the performance curve.  If used to  pump other liquids, 

pump  performance  may  differ  from  rated  performance 

based  on  the  different  specific  gravity,  temperature, 

viscosity,  etc.  of  the liquid  being  pumped.  However,  a 

standard pump may not be safe for pumping all types of 

liquids,  such  as  toxic,  volatile or chemical  liquids,  or 

liquids under extreme temperatures or pressures.  Please 

consult  Marlow  catalogs  as  well  as  local  codes  and 

general  references  to  determine  the  appropriate  pumps 

for  your  particular  application.  Since  it  is  impossible  f�r 

us  to  anticipate  every  application  of  a  Marlow  pump,  1f 

you  plan  to  use  the  pump  for  a  non-swimming  P?OI 

application, 

consult  Marlow  beforehand 

to  determine 

whether  such application may  be proper or  safe  under 

the  circum-stances.  Failure  to  follow  these  instructions 

may result in personal injury, death or property damage. 

WARNING: 

This product can expose you to 

chemicals including Lead, which is known to the 

State of California to cause cancer and birth defects 

or other reproductive harm.

 

For more information go 

to: www.P65Warnings.ca.gov.