12 Technical Reference
12.1 Dimensions
WS009292A
1
3
2
4
1. 255 mm (10 in)
2. 155 mm (6.1 in)
3. 105 mm (4.1 in)
4. 57.5 mm (2.26 in)
12.2 Environmental requirements
Parameter
Value
Operating temperature
• FGC 401: -20°C – +70°C (-4°F – 158°F)
• FGC 411, FGC 421: -20°C – +45°C (-4°F –
113°F)
Storage temperature
-20°C – +85°C (-4°F – 185°F)
Operating humidity
Relative humidity, non-condensing: 90%
Sunlight exposure
UV-resistant
Maximum altitude
• With UL approval: 2000 m (6562 ft)
• Without UL approval: 4000 m (13 123 ft)
12.3 IP-rating
IP20
12.4 Electrical data
Parameter
Value
Supply voltage
• 3-phase:
– 200–460 VAC with neutral
– 400–415 VAC without neutral
• 1-phase: 100–265 VAC
Frequency
50 Hz or 60 Hz
Supply voltage tolerance
± 10%