![Xylem Flygt 2840.180 Installation, Operation And Maintenance Manual Download Page 39](http://html1.mh-extra.com/html/xylem/flygt-2840-180/flygt-2840-180_installation-operation-and-maintenance-manual_3870241039.webp)
Voltage, V
Rated current, A
Starting current, A
Power factor, cos
φ
380 Y
11
68
0.91
400 D
11
78
0.87
400 Y
11
72
0.86
415 D
10
67
0.92
440 D
10
71
0.86
500 D
8.7
59
0.89
500 Y
8.6
53
0.9
525 D
8.2
51
0.9
550 D
7.9
55
0.88
660 Y
6.4
43
0.92
690 Y
6.3
45
0.88
1000 Y
4.3
30
0.89
3-phase, 60 Hz
Motor type:
• 2 pole
• 3,500 rpm
• 6.6 kW (8.8 hp)
Voltage, V
Rated current, A
Starting current, A
Power factor, cos
φ
200 D
24
185
0.91
208 D
24
194
0.88
220 D
22
159
0.93
220 Y//
22
158
0.92
230 D
21
167
0.9
230 Y//
22
166
0.89
240 D
21
175
0.86
240 Y//
22
174
0.85
380 D
13
101
0.9
380 Y//
13
92
0.93
400 D
13
107
0.85
400 Y//
13
94
0.88
440 D
11
80
0.93
440 DSER
11
77
0.91
440 YSER
11
79
0.92
460 D
11
84
0.9
460 DSER
11
83
0.9
460 YSER
11
83
0.89
480 D
11
88
0.86
575 D
8.5
64
0.91
575 Y
8.4
58
0.92
600 D
8.5
67
0.88
600 Y
8.4
61
0.88
1-phase, 60 Hz
Motor type:
Technical Reference
Flygt 2840.180 Installation, Operation, and Maintenance Manual
37