Assembly: Install single piece outer piston (B) into bearing cover (9) with piston tops pointing 
away from motor (See picture on parts list). Slightly bend outer piston (B) along pre-moulded 
crease to aid assembly. Place diaphragm in Bearing cover (9) with the moulded o-ring seals 
facing away from the motor. Insert each inner piston through the diaphragm into the outer 
piston. Turn each piston unit fully seated. Align cam/bearing kit (10) with outer piston (B). 
Secure with cam/piston screws using 2Nm of torque. 

Assemble lower housing (8, 9 &10) to motor. Set screw MUST be positioned over shaft 
indentation and securely tightened. 

Reassemble pump upper housing (4, 5 & 7). Check that rubber ferrules are installed in the 
upper housing and the O-ring is properly seated before inserting the valve assembly (7) into the 
upper housing assembly (5). Align pump assembly to motor and tighten pump head screws 
evenly to 3Nm torque. 

PRESSURE SWITCH CONTROL. 

  

This may be used to create an automatic pressure system and must be used in conjunction with 
an accumulator tank to avoid rapid on-off cycling of the pump.  This type of control may be used 
to avoid over-pressurisation of the pump on other applications.  A pressure relief by-pass 
version is also available as a pump safety feature. 

Setting the Large Adjustable Pressure Switch (if fitted).

  

                

 

 

 

 

 

 

 

 

This procedure should be carried out with care by a competent technician. 

 Disconnect the 

electrical supply, remove the switch cover and check that there are no exposed electrical 
connectors before re-connecting the supply.

 

 
NOTE:  Factory fitted pressure switches are pre-adjusted. Check with your pump supplier, if 
necessary, before making adjustments. 

1.  Loosen the differential nut (D) completely 

2.  Adjust the range nut (R)  to the required 

cut-in

 pressure, using a suitable pressure gauge in 

the discharge pipework close to the pump. 

3.  Tighten the differential nut (D) to give the required 

cut-out 

pressure. 

 

 

Fixed Setting Pressure Switches        

These are not adjustable.  These switches are 

not

 IP55 and require protection from liquids and 

mechanical damage. The complete unit should be fitted in an enclosure. Note: Enclosure 
should allow heat to dissipate and keep the motor pump ambient temperature below 40

o

C. 

(D) Adjusting screw - 

differential 

 

(R) Adjusting screw - 

range 