Training and Qualifications 

5.1  Requirements 

The skills required to complete this work are: 

  Knowledge of electrical wiring and safety 

  Minor hardware installation (bolts and nuts) 

 

Related Documents 

Reference 

Letter 

Part Number 

Description 

Ref.A 

Battery_cable_illustrated_drawing.
pdf 

Diagram for battery cable connector 

Ref.B 

Chasqui_radar_connection_illustr
ated_drawing.pdf 

Diagram for Telecom Board radar 
connector 

 

Safety 

There are some potential hazards which could damage equipment or cause risk of injury. 

 Static discharge to electronic equipment 

 Battery discharge and fire 

 Pinching  

 Working near a confined space 

 

7.1  Mitigating Risk when Servicing a Unit 

Please review the following before attempting to service a unit 

 Inspect outside of enclosure for damage before attempting service. If the unit appears 

physically damaged in any way, do not redeploy unit. Disconnect the battery if it is safe 
to do so and contact your Xylem Representative to arrange for safe disposal. 

 Do not service the device while the radar is operating. 

 When servicing in the field, remove the radar from the manhole and move to a safe and 

dry location before opening the enclosure. 

 Disconnect the battery from the electronic circuitry whenever the enclosure is opened. 

 Please read the remainder of this document and adhere to all requirements listed herein. 

 

7.2  Battery Requirements 

Caution 

  The  battery  used  in  this  device  may  present  a  risk  of  fire  or  chemical  burn  if 

mistreated.    Do  not  disassemble,  heat  above  100C,  or  incinerate.    Replace  battery  with 
Vitzrocell SB-D024S+CON only.  Use of another battery may present a risk of fire or explosion.  
Caution 

 DO NOT attempt to charge the batteries. The batteries are primary cells and should 

not be charged. Doing so risks potential fire or explosion. 
 

Tools and Consumables 

No special tools are required to service the radar. 
 
The  installer  will  be  required  to  replace  the  tamper  detection  tag  (consumable  item)  when 
servicing the unit. The tags are supplied with the support bar installation kit and the support 

Summary of Contents for emnet BLU-X Radar B

Page 1: ...1 Table of Contents 2 Legal Statements 2 2 1 FCC 2 2 2 Antenna care unauthorized modifications 3 2 3 Responsible Party 3 2 4 Manufacturer 3 3 Overview 4 3 1 Guideline 4 4 Technical Specifications 4 4...

Page 2: ...responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to pa...

Page 3: ...lows NOTE This equipment may only be operated indoors Operation outdoors is a violation of 47 U S C 301 and could subject the operator to serious legal penalties 2 2 Antenna care unauthorized modifica...

Page 4: ...76 values Default recording time 2 5 years 4 4 Communication Connectivity Cellular LTE Communication Frequency Real Time Hourly Daily or Weekly Antenna Integrated optional external 4 5 Battery Type Fa...

Page 5: ...is safe to do so and contact your Xylem Representative to arrange for safe disposal Do not service the device while the radar is operating When servicing in the field remove the radar from the manhol...

Page 6: ...site assessment followed by installation of the support hardware and then mounting the radar to the support bar before proceeding to install the assembly into the manhole 9 1 Site assessment No Descri...

Page 7: ...igure the radar for different site conditions These are changed by editing parameters At the time of writing the parameters that the installer will need to update are 1 0 to 30 0 Total manhole height...

Page 8: ...on and replacement of desiccant 6 Inspection and replacement of batteries Step 1 above should be completed according to support bar service documentation Steps 2 6 are addressed below 11 1 Inspection...

Page 9: ...If the unit appears to have been damaged please request a replacement unit 11 3 Opening of the enclosure and inspection of the interior No Description Illustration Orient the radar with the lid facing...

Page 10: ...was consumed Please estimate and record how much the desiccant was consumed Replace with new packs of the same type 11 5 Inspection and Replacement of Batteries Battery removal is described as follows...

Page 11: ...If battery packs and cables appear to be in good condition remove battery packs and safely discard following all legal requirements Note Dispose of used battery promptly Keep away from children Do no...

Page 12: ...without opening the enclosure by looking through the optically transparent lid If the enclosure is opened look for pools droplets on surfaces and corrosion of metal surfaces and connectors Damage to...

Page 13: ...upport 12 2 Returning a device for service If there is an issue which cannot be resolved or if the service technician has identified a hardware issue please disconnect the batteries if it is safe to d...