4.2 Mounting of coupling (some models are equipped 
with coupling)
  Power  must  be  cut  off  or  switched  off  before 
maintenance operation.
Installation steps:
1. Check the water pump and motor shaft to remove all
burrs, rust, etc.
2. Install the positioning ring 2 and screw 4 onto the
motor shaft, and locate the ring end face level with the
motor shaft end face, then use the electric drill to spot-
face the motor shaft, and the position corresponds to
that of screw 4.
3. Install the positioning plate 3 and lifting bolt 8 onto
the pump shaft without tightening. The positioning
plate can be moved up and down.
4. Align the groove of the coupling with locating ring
2 before adjusting locating plate 3, so that the coupling
can  be  installed  smoothly  on  locating  ring  2  and
locating plate 3.
5. Tighten the lifting bolt 8 on the pump shaft end until
it is in place to lift the rotor assembly.
6. Then install the other half coupling on the locating

1. Coupling 2. Positioning ring 3. Positioning plate
4. Screw 5. Bolt 6. Washer
7. Nut 8. Lifting bolt
Installation of the coupling must be very careful so
that the pump runs reliably for long periods of time.
Incorrect  coupling  installation  causes  noise  and
vibration, as well as damage to sliding bearings and
seals.

Fig. 8  Schematic diagram of coupling structure

Fig.7

1-Concrete base

2-Shock absorber

Pump installation procedure:
a)The anchor bolts are mounted through the holes on
pump base and align the pump suction flange with the
pipeline flange.

b)Perform  the  first  grouting  till  20-30mm  below
the pump base. Do not move the equipment during
grouting  and"  the  anchor  bolts  should  be  placed
vertically in the foundation holes.

b)When the concrete is completely cured, align the
pump suction/discharge flange and pipeline flange
again and perform the second grouting till the pump
base.

ring 2 and locating plate 3.
7. Then screw down bolt 5, nut 7 and washer 6 evenly.
Check the middle joint of the coupling.
8. Disk  coupling,  it  is  confirmed  that  the  impeller
and shaft assembly can rotate normally, and the shaft
hopping between the coupling and the gland is not
greater than 0.1mm.
9. Finally install the coupling guard.

Summary of Contents for Bell & Gossett GLC Series

Page 1: ...GLC series pipeline pump Installation Manual Please leave the manual to the user Read the instructions carefully before Installation operation and maintenance...

Page 2: ...onnection 7 4 4 Electrics connection 7 5 Operation 7 5 1 Preparation and checklist prior to startup 8 5 2 Priming 8 5 3 Startup 8 5 4 Operation and monitoring 8 5 5 Shutdown 8 5 6 Dismantling 9 5 7 Al...

Page 3: ...1...

Page 4: ...2...

Page 5: ...e in m Hv liquid saturated vapor pressure unit is m converted to water column height Hs safety margin in m usually 0 5m Such as Pb 1bar pump cavitation margin NPSHr 2m Pipe loss Hf 2m safety margin Hs...

Page 6: ...ing and 6 Service in this manual for more information on the mechanical seal and potentialrisks3 3 Shipping handling and storage 3 1 Shipping handling Check in time if any part is damaged during the s...

Page 7: ...han the width around the base of the pump set When installed with vibration isolation the vibration damping platform should be 150mm wider than the water pump vibration isolation base Elevation on top...

Page 8: ...oning plate 4 Screw 5 Bolt 6 Washer 7 Nut 8 Lifting bolt Installation of the coupling must be very careful so that the pump runs reliably for long periods of time Incorrect coupling installation cause...

Page 9: ...7...

Page 10: ...8...

Page 11: ...9...

Page 12: ...tention to the noise during normal operation If there is vibration abnormal noise abnormal temperature rise of motor or other fault phenomena are observed stop immediately to find out and eliminate th...

Page 13: ...11...

Page 14: ...12 9 1 Vertical single pipeline pump without coupling...

Page 15: ...upling No Description No Description 1 Impeller nut 8 Motor 2 Impeller 9 Coupling parts 3 Wear ring 10 Electric motor bracket 4 Pump cover 11 Sealing gland 5 Mechanical seal 12 Sliding bearing 6 Flush...

Page 16: ...escription 1 Impeller nut 7 Sliding bearing 13 Mechanical seal 2 Pump body 8 O ring 14 Mechanical seal retainer 3 Impeller 9 Electric motor bracket 15 Shaft Sealing Ring 4 Wear ring 10 Coupling parts...

Page 17: ...15...

Page 18: ...16...

Page 19: ...17...

Page 20: ...Mx Mb DN40 450 350 410 730 200 300 400 550 DN50 600 500 550 1000 250 350 450 600 DN65 800 650 700 1250 300 350 500 700 DN80 950 750 850 1500 350 400 550 750 DN100 1250 1000 1150 1950 400 500 650 850...

Page 21: ...In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of...

Reviews: