Field Cables and Sensors
Most field cables have at least one sensor port in which a sensor must be installed. Ports on these cables are sensor-specific, so it is
important to ensure the correct sensor is installed in each port. Available field cables are listed in the table below:
Throughout the manual, the term “sensor” refers to the removable portion or electrode sensing portion of the cable assembly. For
example, the DO sensor or pH sensor is the part that can be removed from a field cable and replaced with a new sensor. Sensors
that are available for field cables include:
ISE (Ion Selective Electrode) notates a port that can accept pH, ORP, Ammonium, Nitrate, Chloride, and, in some
cases, a pH/ORP combination sensor (6051030 and 6051020 cables only).
YSI Item #
Description
605790-1, 4, 10, 20, or 30
Quatro (4 port), Dual ISE/Cond/DO/Temp. A user-replaceable conductivity/temp sensor is
included with each cable. There is one DO port and two ISE ports in which sensors can be
installed.
DO and ISE sensors sold separately. Does not accept 1003 pH/ORP combo
sensor.
6052030-1, 4, 10, 20, or 30
DO/Cond/Temp. Includes built-in conductivity and temp sensors. There is one DO port in
which a DO sensor can be installed.
DO sensors sold separately.
6051030-1, 4, 10, 20, or 30
ISE/Cond/Temp. Includes built-in conductivity and temp sensors. There is one ISE port in
which an ISE can be installed.
ISE sensors sold separately.
6051020-1, 4, 10, 20, or 30
DO/ISE/Temp. Includes a built-in temp sensor. There is one DO port and one ISE port in
which sensors can be installed.
DO and ISE sensors sold separately.
6051010-1, 4, 10, 20, or 30
Dual ISE/Temp. Includes a built-in temp sensor. There are two ISE ports in which sensors can
be installed.
ISE sensors sold separately. Does not accept 1003 pH/ORP combo sensor.
60530-1, 4, 10, 20, or 30
Cond/Temp. Includes built-in conductivity and temp sensors; no additional sensors needed.
60520-1, 4, 10, 20, 30, or 100
DO/Temp. Includes a built-in temp sensor. There is one DO port in which a DO sensor can be
installed.
DO sensors sold separately.
60510-1, 4, 10, 20, or 30
ISE/Temp. Includes a built-in temp sensor. There is one ISE port in which an ISE can be
installed. ISE sensors sold separately.
Does not accept 1003 pH/ORP combo sensor.
YSI Item #
Description
605202
Galvanic DO Sensor
605203
Polarographic DO Sensor
605101
pH Sensor
605102
ORP Sensor
605103
pH/ORP Sensor (for use with 6051030 and 6051020 cables only)
605104
Ammonium ISE, NH4+
605105
Chloride ISE
605106
Nitrate ISE
605323
1001A Amplified pH Sensor
605216
1001A Amplified pH Sensor Kit; includes a required guard extension for 6051010 and 6051020 cables
005560
Conductivity and temperature sensor for Quatro cables; included with new Quatro cables