NOTICE:
Do not use Variable Frequency Drive (VFD) with this unit.
NOTICE:
Do not use any type of soft start equipment with this unit.
Cable requirements
NOTICE:
Leakage into the electrical parts can cause damaged equipment or a blown fuse. Keep
the cable ends dry at all times.
• The cables must be in good condition, not have any sharp bends, and not be pinched.
• The cables must not be damaged and must not have indentations or be embossed
(with markings, etc.) at the cable entry.
• The cable entry seal sleeve and washers must conform to the outer diameter of the
cable.
• The minimum bending radius must not be below the acceptable value.
• If a cable is used again, then a short piece must be peeled off. Make sure that the
cable entry seal sleeve does not close around the cable at the same point again. If the
outer sheath of the cable is damaged, then replace the cable.
• The voltage drop in long cables must be considered. The rated voltage of the drive
unit is the voltage that is measured at the cable connection point in the unit.
• The cables must be long enough for maintenance work.
• For SUBCAB
®
cables, the twisted pair copper foil must be trimmed.
• All unused conductors must be insulated.
• The cables must be run so that they cannot be sucked into the unit.
• The cables must comply with the local regulations.
• A screened SUBCAB
®
cable must be used between the pump and the gateway or
controller.
For more information, contact the sales and service representative.
Electromagnetic compatibility
Make sure that the equipment or system in which the product is incorporated complies
with the electromagnetic compatibility (EMC) legislation of that country.
The unit complies with and is approved according to EMC Directive 2014/30/EU. In the
European Union, equipment in which the unit is incorporated must comply with the same
directive.
The unit is not intended to be used in low-voltage public networks which supply domestic
premises, without a 3–phase VFD mains filter to reduce radio frequency interference.
• Without a 3–phase VFD mains filter, the unit is expected to cause interference in
accordance with EN 61800-3 category C3.
• With a 3–phase VFD mains filter 85 03 10 installed, the unit complies with
EN 61000-6-4 and EN 61000-6-2.
For more information, contact the sales and service representative.
5.3 Make the electrical connections
5.3.1 Prepare the SUBCAB
®
cables
This section applies to screened SUBCAB
®
cables with twisted-pair control cores.
5 Electrical Installation
26
6020.180/090 Installation, Operation, and Maintenance Manual