XVision PC810 Instruction Manual Download Page 3

 

P.3

 

STEP 3: Adjust the vertical and horizontal angles by loosening screws 

(A&B) as in Figure 3 and by turning the bracket vertically and 
horizontally.       

                                                                                                     

                 

3. Wiring instructions 

STEP 1:Connect the coaxial cable between the camera and the monitor 

using a 75Ohm coaxial cable. 

STEP 2: Insert the AC plug into the AC power socket and the DC plug to the DC 

Jack.  

Note: AC Adapter Sold separately. 

 

A

B

Summary of Contents for PC810

Page 1: ...mera uses high sensitive 1 3 1 4 interline transfer CCD Image Sensor CCD Charge Coupled Device and all state circuitry which provides extremely long life and high reliability This Camera offers excellent image quality with low lag and high burn resistance and is not subject to distortions from magnetic fields Highly resistance to shock and vibration and easy to install this Camera is a very good c...

Page 2: ...P 2 2 Installation STEP 1 Secure the bracket to the wall with screws included as shown in Figure 1 STEP 2 Attach the Camera Case to the bracket as shown in Figure 2 ...

Page 3: ...3 and by turning the bracket vertically and horizontally 3 Wiring instructions STEP 1 Connect the coaxial cable between the camera and the monitor using a 75Ohm coaxial cable STEP 2 Insert the AC plug into the AC power socket and the DC plug to the DC Jack Note AC Adapter Sold separately A B ...

Page 4: ...60s 1 100 000s CCIR PAL 1 50s 1 110 000s S N Ratio More than 48 dB Gamma Characteristic GAMMA 0 45 Sync System Internal Negative sync Video Output 1 Vp p 75 Ohms BNC or F connector Audio Optional 2 Vp p 50 Ohms RCA connector for model Audio including PIR working sensor only Power Supply DC 12V 10 Power Consumption PIR Sensor not included 1 32W 1 44W Lens Furnished Corn Lens f 3 7mm F2 0 Operating ...

Page 5: ...wider pattern 2 Sensitivity Adjustment B To lower sensitivity Turn counter clockwise for detection in narrow areas For closure period of N C N O relay connected to an alarm panel light control or recording control of time lapse VCR etc A Max time Turn counter clockwise B Min time Turn clockwise 3 Dwell Time Adjustment Adjustable from 2 to 40 sec Top Center pins of J4 must be selected to adjust the...

Page 6: ...or Recording control will be triggered immediately 5 Pulse Control Once or twice 4PINS 2PAIRS w jumper connector Position 2 Set to Twice when PIR detects someone 2 times within 15 seconds N C Normally Closed A For connection to Security panel or Light control CCTV etc B With anti tamper function for 24 hours 6 Output Terminals 24 Hour Anti Tamper N O Normally Open Contacts P S Relay output current...