- Xhouse unit connection to the power 

- Connection of the unit in to the electric box 

Input wire is ready from the manufacturer for connection in to the 

electric box. 
- For connection of the income wire to the electric power network use 
appropriate components. (IE connectors, spring clamps) 

- Connection of the unit to the electric socket 

Income wire is possible to connect with plug with security connector 

(pin) – this is not part of the delivery.

 

 

Installation of the income wire to the electric box or installation of the plug to the income wire and connection to the electric 

power network has to be performed only by authorised person and inline with safety law instructions valid in the area of the 
installation. 

5) Controls – electro accessories to the Xflat 

 

-

 For the correct operation of the unit (in manual mode), there is no need to connect anything else. It is ready for immediate use after installation 

on the wall. For operation in automatic mode, you must connect the air quality sensor accessories CO2 (NL-ECO-CO2) or RH (NL-ECO-RH).

 

-

 

Connection of electrical accessories 

     

Before connecting electrical accessories, always switch off the unit at the remote control and the main switch. 

 

- Connect the electrical accessories in the control box. To connect accessories, use the membrane multi-through. To access the control 

box, proceed as follows: 
 

-  Connection of CO2 (NL-ECO-CO2) and RH (NL-ECO-
RH) sensors - AQS sensors (AQS CO2 

- Spring clamps with manual wire locking 

are used to connect the individual 
components. Both a licna-type conductor 

(cable with a sleeve) and a solid conductor 
(wire) can be installed in the terminals 

with a cross-section ranging from 0.5 to 
1.5 mm², exposed length 10 mm. Before 
inserting the wire into the terminals, first 

press the locking orange button. Then 
insert the wire, release the lock and check 

that the wire is properly secured by pulling 
slightly on the clamp. If you need to 

remove the wire from the terminal, the 
procedure is the same. Choose the 

optimal conductor cross-section according 
to the length of the conductor route. 

a)

 loosen the grommet nuts 

e)

 Connect the cable to the appropriate terminals in the motherboard according to the 

- K It is possible to connect 2x AQS sensors (1xCO2 and 1xRH) to 
the unit, which are used to measure the content of CO2 
concentration and humidity – RH in the air at the place where the 
sensors are installed. Thanks to the sensors, it is possible to 
operate the unit in automatic mode, which automatically controls 
the operation and air output of the unit according to the current 
need in the given space where the sensors are installed. At the 
same time, this method of management is the most efficient in 
terms of economy of operation – it only ventilates as needed. If 
necessary, it is possible to connect up to 8 sensors of one type to 
the unit using the "PRO-SUM-08" accessory. 

Sensor AQS 
RH 

Sensor AQS 
CO

2

 

b)

 unscrew the securing screws of the 

regulation cover - remove the cover 

c)

 pass the cable through the membrane 

Terminal 

bridge for 

switching NC 

and NO 

switching logic 

GREEN-YELLOW (PE) – 

SECURITY WIRE 

BLUE (N) – NEUTRAL WIRE 

BLACK/BROWN (L) – PHASE 

WIRE 