background image

16 

 

INSTALLATION INSTRUCTIONS 

Grounding 

• 

The power cord is equipped with a three-prong (grounding) plug which mates with a 
standard three-prong grounding wall receptacle to minimize the possibility of 
electrical shock hazard from the range. 

• 

All cord connected appliance shall include instructions relative to location of the wall 
receptacle and a warning to the user to disconnect the electrical supply before 
serving the appliance. 

• 

Where a standard two-prong wall receptacle is encountered, it is the responsibility 
and obligation of the customer to have it replaced with a properly grounded three- 
prong wall receptacle. Do not cut or remove the grounding prong from the power 
cord. 

 

Connect Range to Gas Supply 

• 

Install a manual gas line shut-off valve in the gas line in an easily accessed location 
outside the range in the gas piping external to the appliance for the purpose of 
turning on or shutting off gas to the appliance. 

 

• 

Install male ½” flare union adapter to ½” NPT internal thread elbow at inlet of 
regulator. On models equipped with standard twin burners, install the male pipe 
thread end of the 

½” flare union adapter to the ½” NPT internal thread at inlet of 

pressure regulator. Use a wrench on the regulator fitting to avoid damage. 

 

• 

Install male 

½” or ¾” flare union adapter to the NPT internal thread of the manual 

shut-off valve, taking care to secure the shut-off valve to keep it from turning. 

 

• 

The gas supply pressure for checking the regulator setting is 6in (Natural Gas) and 

11inch

LP gas

connect flexible gas line connector to the regulator on the range. 

Position range to permit connection at the shut-off valve. 

 

• 

When all connections have been made, check that all range controls are in the 

“off” 

position and turn on the main gas supply valve. 

 

• 

Leak testing of the appliance shall be conducted according to the manufacture’s 
instructions .Use some soap water (50% water and 50% soap) or a leak detector at 
all joints and connections to check for leaks in the system. Do not use a flame to 
check for gas leaks. 

 

• 

The appliance must be isolated from the building’s gas supply piping system by 
closing its individual manual shut-off valve during any pressure testing of the gas 
supply piping system at test pressure equal to or less than ½ psig (3.5kPa). 

Summary of Contents for XTA-PR30

Page 1: ...XTA PR48 XTA PR36 XTA PR30 Freestanding Gas Ranges Range Installation Guide and User Manual...

Page 2: ...operating your new appliance for the first time This manual contains instructions on how to properly install and set up your new range as well as insights into many of the unique features that our pr...

Page 3: ...t store or use gasoline liquid propane cylinder or other flammable vapors and liquids in the vicinity of this appliance What to do if you smell gas Do not try to light any appliance Do not touch any e...

Page 4: ...oided could result in minor or moderate injury CAUTION when used without the safety alert symbol indicates a potentially hazardous situation which if not avoided could result in property damage IMPORT...

Page 5: ...bya licens ed installer an approved service agency or your gas supplier To reduce the risk of tipping the appliance the appliance must be secured by properly installing the anti tip device packed wit...

Page 6: ...adequate manpower is required when moving the range to avoid personal injury or damage to the unit or the floor The unit is heavy and restson adjustable steel legs Failure to follow this advice may r...

Page 7: ...om the burners should be blue in color In addition the flames should be stable free of yellow tipping excessive noise and lifting However this yellow tipping should be restricted to the primary flame...

Page 8: ...only the bottom of the utensil and does not overlap at the sides of the utensil Utensils pots and pans that conduct heat slowly i e glass pots should be used in conjunction with burner flames at a low...

Page 9: ...essure in accordance with the inlet pressure rating of the gas appliance pressure regulator supplied MINIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR LP GAS 14 0 IN W C MINIMUM GAS SUPPLY PRESSURE TO APPL...

Page 10: ...ll a non combustible material on the rear wall above the range and up to the vent hood It is not necessary to install non combustible materials behind the range below the counter top height The minimu...

Page 11: ...11 36 36...

Page 12: ...12 48 36...

Page 13: ...Installation Dimensions and Clearances Installation Diagram Installation Diagram 13...

Page 14: ...Installation Diagram 14...

Page 15: ...h local codes or in the absence of local codes in accordance with the National Electrical Code ANSI NFPA 70 latest edition In Canada electrical grounding must be in accordance with the current CSA C22...

Page 16: ...odels equipped with standard twin burners install the male pipe thread end of the flare union adapter to the NPT internal thread at inlet of pressure regulator Use a wrench on the regulator fitting to...

Page 17: ...th no yellow tipping or lifting flames Check ignition of oven burner 3 Visually check tubular burner oven burner re ignition to be sure both rows of burner ports are relighting each time 4 Check for g...

Page 18: ...is turned to the Hi position all the burners will spark Do not attempt to disassemble or clean around any burner while another burner is on Do not touch any burner cap burner base or igniter while the...

Page 19: ...ame should be steady and blue in color Foreign material in the gas line may cause an orange flame during initial operation Power Failure If the gas does not ignite within four seconds turn off the val...

Page 20: ...rby surfaces during oven or broiler operation they may become hot Burner Grates 1 The grates must be properly positioned before cooking Improper installation of the grates may result in scratching of...

Page 21: ...eat is then circulated by natural airflow This is a traditional bake setting Infrared Broil The broil burner is located at the top of the oven This burner heats the metal screen until it glows The glo...

Page 22: ...vection roasting it is important that you use the broiler pan for best convection roasting results The pan is used to catch grease spills and has a cover to prevent grease splatters Convection Defrost...

Page 23: ...tion before turning or removing food Setting Broil The Oven selector knob controls the Broil feature When broiling heat radiates downward from the oven broiler for even coverage The Broil feature temp...

Page 24: ...remove dust or any protective coating 2 Rinse with clean water and wipe off to dry with soft clean lint free towel cloth 3 A stainless steel cover that is sized to fit on top of the surface when the g...

Page 25: ...with a solution of mild detergent and warm water Do not use abrasive cleaners or scrubbers they will permanently damage the finish Dry the components with a soft lint free cloth Oven Window Clean all...

Page 26: ...off the power at the main power supply Remove the lens cover from the housing by pulling straight out To prevent electrical shock or personal injury make sure the oven and light bulb are cool and pow...

Page 27: ...pe of gas Regulator is not installed is faulty or is set for the wrong type of gas Clean burner bezel ring ports with straightened paper clip needle or wire Remove and carefully re install burner beze...

Page 28: ...28...

Page 29: ......

Reviews: