INSTALLATION INSTRUCTIONS 

 

 

INSTALLATION INSTRUCTIONS 

 

 

This appliance can be used with Natural Gas and LP Gas. It is shipped 
from the factory adjusted for use with Natural Gas. Propane 
conversion kits can be purchased separately. 

 

The  maximum  inlet  gas  supply  pressure  incoming  to  the  gas  appli- 
ance  pressure  regulator 

is  20’’  water  column  (5  kPa).  The  minimum 

gas  supply  pressure  for  checking  the  regulator  setting  shall  be  at 
least 

1“ w.c.  (249  Pa)  above  the  inlet  specified  manifold  pressure  to 

the appliance (this operating pressure is 
4” w.c. (1.00 kPa) for Natural Gas and 10” w.c. (2.75 kPa) for LP Gas). 

 

ATTENTION 

A manual valve shall be installed in an accessible location in the gas 
line external to the appliance for the purpose of turning on or shut- ting 
off gas to the appliance. 

 

WARNING 

Do not use aerosol sprays in the vicinity of this appliance while it is in 
operation 

 

INSERTING THE COOKTOP 

After  having  removed  the  various  loose  parts  from  the  internal  and 
external packing, make sure that the cooktop is not damaged and is 
suitable for the  specific gas  usage. The gas  type  label  is on the  un- 
derside of the cooktop base. 

 

In case of doubt, do not use the appliance and contact skilled 
personnel. 

 

Keep  all  the  packaging  parts  (polystyrene  foam,  cardboard,  staples, 
etc.)  away  from  children.  Consider  the  critical  dimensions  of  the  ap- 
pliance,  before  making  an  opening  in  the  top  surface  of  the 
countertop. (relative measurements as per Page 18-19, Fig. 1, 2). 

ATTACHING THE COOKTOP 

To  prevent  liquids  from  leaking  accidentally  into  the  underlying 
storage space, the appliance is equipped with a special gasket. 
To apply this gasket, carefully  follow the instructions in Fig. 3. Lay out 
the  protective  sealing  strips  along  the  edges  of  the  opening  in  the 
countertop  and  carefully  overlap  the  strip  end.  (See  Fig.  3).  Insert  the 
cooktop into the countertop opening. With a screwdriver assemble 
the brackets A to the cooktop bottom by means of the screws B. 
(See  Fig.  4).  Slide  the  hooks  into  position  and  secure  them  with  the 
screws.Trim  the  part  of  the  sealing  strips  which  extend  beyond  the 
hotplate base. 

 

GAS CONNECTION 

Before connecting the appliance to the gas supply, first remove the 
plastic plug on which is press- fitted into the gas inlet union; to 
remove, just pull it off. 

 

1. 

Check the 

‘gas type’ sticker attached to the cooktop. Details of the 

injector sizes used are recorded on the data plate located on the 
base of the appliance. 

 

2. 

This appliance shall be installed in accordance with installation re- 

quirements of the local gas authority of the appropriate 
installation code. 

 

3. 

Before installing the cooktop consider the location of the gas supply 

and routing the gas line.(Refer fig.6) 

 

4. 

For LPG models: the gas supply is connected to the regulator which 

is supplied loose. The inlet connection has a 1/ 

2” B.S.P. male thread. IT 

IS ESSENTIAL THAT THE ELBOW ON THE APPLIANCE BE HELD FIRMLY 
WITH A SPANNER WHEN CONNECTING THE SUPPLY. DO NOT OVER 
TIGHTEN. The regulated pressure For LPG is 10” w.c. (See Fig. 5). 

 

 

Summary of Contents for XTA-PC30

Page 1: ...Slide in Gas Cooktops Models XTA PC30 XTA PC36 Cooktop Installation Guide and User Manual XtremeAIRUSA com...

Page 2: ...leaves the factory after thorough quality inspection and testing Our distributors and our service partners are ready to answer any questions you may have regarding how to install use and care for your...

Page 3: ...pipe thread You will need to determine the fitting required depending on the size of your gas supply line the flexible metal connector and the shutoff valve The appliance when installed must be elect...

Page 4: ...top relative measurements as per Page 18 19 Fig 1 2 ATTACHING THE COOKTOP To prevent liquids from leaking accidentally into the underlying storage space the appliance is equipped with a special gasket...

Page 5: ...fterwards open the relative burner knob at maximum position keeping it pressed then measure the outlet pressure from the burner injector d Once the pressure checking has been carried out replace the b...

Page 6: ...Gas at a nominal outlet pres sure of 4 W C or LP gas at a nominal outlet pressure of 10 W C and it is pre arranged from the factory to operate with one of these gas pres sure as indicated in the pre a...

Page 7: ...vapors and liquid Do not store dangerous or flammable material in the cabinet areas above appliance store them in a safe place in order to avoid poten tial hazards For safe use of appliance do not use...

Page 8: ...y turning the knob in counter clockwise to your desired flame height Should the burner fail to light up turn the knob to its original position and try again NOTE When first used the gas burner will no...

Page 9: ...ening the attachment screws of each burner un screwing the cooktop attachment nuts which are visible at the bottom of the surface removing the cooktop stainless steeltop and finally re placing the def...

Page 10: ...REFERENCE FIGURES REFERENCE FIGURES Fig 1 Fig 2 Fig 3 Fig 4 30 MODEL W 29 8 D 27 36 36 MODEL W 35 8 D 27 36 18 19 Table n 1 c...

Page 11: ...REFERENCE FIGURES Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 14 Fig 15 Fig 13 20 21...

Page 12: ......

Reviews: