INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
This appliance can be used with Natural Gas and LP Gas. It is shipped
from the factory adjusted for use with Natural Gas. Propane
conversion kits can be purchased separately.
The maximum inlet gas supply pressure incoming to the gas appli-
ance pressure regulator
is 20’’ water column (5 kPa). The minimum
gas supply pressure for checking the regulator setting shall be at
least
1“ w.c. (249 Pa) above the inlet specified manifold pressure to
the appliance (this operating pressure is
4” w.c. (1.00 kPa) for Natural Gas and 10” w.c. (2.75 kPa) for LP Gas).
ATTENTION
A manual valve shall be installed in an accessible location in the gas
line external to the appliance for the purpose of turning on or shut- ting
off gas to the appliance.
WARNING
Do not use aerosol sprays in the vicinity of this appliance while it is in
operation
INSERTING THE COOKTOP
After having removed the various loose parts from the internal and
external packing, make sure that the cooktop is not damaged and is
suitable for the specific gas usage. The gas type label is on the un-
derside of the cooktop base.
In case of doubt, do not use the appliance and contact skilled
personnel.
Keep all the packaging parts (polystyrene foam, cardboard, staples,
etc.) away from children. Consider the critical dimensions of the ap-
pliance, before making an opening in the top surface of the
countertop. (relative measurements as per Page 18-19, Fig. 1, 2).
ATTACHING THE COOKTOP
To prevent liquids from leaking accidentally into the underlying
storage space, the appliance is equipped with a special gasket.
To apply this gasket, carefully follow the instructions in Fig. 3. Lay out
the protective sealing strips along the edges of the opening in the
countertop and carefully overlap the strip end. (See Fig. 3). Insert the
cooktop into the countertop opening. With a screwdriver assemble
the brackets A to the cooktop bottom by means of the screws B.
(See Fig. 4). Slide the hooks into position and secure them with the
screws.Trim the part of the sealing strips which extend beyond the
hotplate base.
GAS CONNECTION
Before connecting the appliance to the gas supply, first remove the
plastic plug on which is press- fitted into the gas inlet union; to
remove, just pull it off.
1.
Check the
‘gas type’ sticker attached to the cooktop. Details of the
injector sizes used are recorded on the data plate located on the
base of the appliance.
2.
This appliance shall be installed in accordance with installation re-
quirements of the local gas authority of the appropriate
installation code.
3.
Before installing the cooktop consider the location of the gas supply
and routing the gas line.(Refer fig.6)
4.
For LPG models: the gas supply is connected to the regulator which
is supplied loose. The inlet connection has a 1/
2” B.S.P. male thread. IT
IS ESSENTIAL THAT THE ELBOW ON THE APPLIANCE BE HELD FIRMLY
WITH A SPANNER WHEN CONNECTING THE SUPPLY. DO NOT OVER
TIGHTEN. The regulated pressure For LPG is 10” w.c. (See Fig. 5).
6
7