1. TYPE 1: TOUCH SCREEN CONTROL (For Pro-X Series PX10, PX12-models)
Note:
This range hood is equipped with remote control and smoke sensor that will self-calibrate within 5 seconds
when the range hood is first electrically activated. Self-calibration will be set when the range hood beeps. LCD panel
will turn off automatically after a period of inactivity.
A.
Activating Smoke Detector Function:
B. Activating Normal Blower Function:
C. Activating Light Function:
D. Activating Power-Off Delay Function:
E. Changing the clock:
While the blower is off:
1.
Touch power sign once; the hour indicator will flashing
2.
use (+) or (-) to adjust to designed hour
3.
Touch power sign again; the “minutes” indicator will flashing
4.
use (+) or (-) to adjust to designed minutes
5.
Touch power sign again to clear the screen. Touch light button to validate. To check time, touch light
button.
Note: The clock display is only for PX10
• Touch
Light
button to turn the lights on or off.
1.
While the range hood is on and the blower is running in normal mode, touch
Power-Off Delay
button to activate delay off timer.
2.
Adjust to desired period of delay of timer by touching (-)
or (+)
button quickly (1-15 minutes).
Timer begins to countdown immediately, when it reaches 0, the blower will shut off.
3.
Display screen will show flashing clock if timer is working
• While the range hood is off,
Touch
(+) to start from lowest speed, F1
Touch
(-) to start from Highest speed, F4
Touch (+) or (-) again to change the blower speed as indicated in LCD panel
00 = blower off
F1 = quiet speed
F2 = low speed
F3 = medium speed
F4 = high speed
• Touch
Auto Function
button to activate the smoke detector auto function mode
NOTE: this function will only worked when there’s a lot of smoke.
ONCE THIS BUTTON IS
TOUCHED, ALL OTHER BUTTONS ARE NOT ACTIVE.