Xtreme XC-14A User & Installation Manual Download Page 6

 

INTRODUCTION

 

The

 

information

 

provided

 

in

 

this

 

manual

 

covers

 

13,200

 

 

29,000

 

BTU/HR

 

Xtreme

 

Cooling

 

units,

 

their

 

basic

 

functions,

 

operating

 

procedures,

 

options

 

available

 

and

 

emergency

 

situations.

 

It

 

also

 

includes

 

information

 

on

 

how

 

to

 

ship,

 

store,

 

handle,

 

and

 

install

 

the

 

equipment.

 

Only

 

detailed

 

requirements

 

of

 

the

 

Cooling

 

units

 

are

 

described

 

herein,

 

and

 

installation

 

must

 

be

 

carried

 

out

 

in

 

accordance

 

with

 

this

 

manual.

 

Electrical

 

installation

 

must

 

also

 

carefully

 

follow

 

local

 

legislation

 

and

 

regulations.

 

Only

 

qualified

 

personnel

 

should

 

conduct

 

these

 

installations

 

as

 

failure

 

to

 

acknowledge

 

electrical

 

hazards

 

could

 

prove

 

to

 

be

 

fatal.

 

PRODUCT

 

DESCRIPTION

 

Xtreme

 

Cooling

 

Portable

 

Air

 

Conditioners

 

feature

 

spot

 

cooling

 

for

 

large

 

areas

 

where

 

cooling

 

of

 

the

 

entire

 

area

 

is

 

not

 

practical

 

or

 

possible.

 

A

 

dedicated

 

spot

 

cooling

 

thermostat

 

controls

 

the

 

unit

 

in

 

this

 

application.

 

These

 

air

 

conditioners

 

can

 

also

 

be

 

used

 

in

 

smaller

 

areas

 

for

 

room

 

cooling.

 

A

 

control

 

panel

 

provides

 

ease

 

of

 

use

 

and

 

contains

 

self

diagnostic

 

functions

 

and

 

displays,

 

showing

 

operating

 

modes,

 

room

 

and

 

set

 

temperatures,

 

and

 

faults.

 

If

 

an

 

abnormal

 

operation

 

occurs,

 

a

 

visual

 

display

 

of

 

the

 

fault

 

is

 

shown.

 

Caster

 

wheels

 

are

 

included

 

for

 

ease

 

of

 

portability.

 

Suitable

 

applications

 

include:

 

factory

 

or

 

work

 

place,

 

industrial

 

kitchen,

 

computer

 

room,

 

emergency

 

cooling,

 

outdoor

 

event,

 

etc.

 

 

XC

14A,

 

XC

22A,

 

XC

30A

 

USER’S

 

MANUAL

           

Portable

 

Air

 

Conditioners

 

Page

 

6

 

Xtreme

 

Power

 

Conversion®

 

(XPC)

 

Corporation

 

SHIPPING

 

LIST

 



(1)

 

PORTABLE

 

COOLING

 

UNIT

 



(1)

 

User’s

 

and

 

Installation

 

Manual

 



(1)

 

POWER

 

CORD

 

HOLDER

 



(4)

 

RUBBER

 

STOPPERS

 



DISCHARGE

 

/

 

SUPPLY

 

AIR

 

DUCTS

 

(1)

 

XC

14A

 

(2)

 

XC

22A

 

(3)

 

XC

30A

 

Xtreme

 

Power

 

Conversion®

 

(XPC)

 

Corporation

                                  

Page

 

19

 

XC

14A,

 

XC

22A,

 

XC

30A

 

USER’S

 

MANUAL

           

Portable

 

Air

 

Conditioners

 

Summary of Contents for XC-14A

Page 1: ...le Air Conditioners Models XC 14A XC 22A XC 30A User s Installation Manual Xtreme Power Conversion XPC Corporation XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Page 24 Xtreme Power Conversion XPC Corporation ...

Page 2: ...ting Chart SPECIFICATIONS 18 SHIPPING LIST 19 OBTAINING SERVICE 20 XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY 21 OPTIONS 23 Ambient Air Adaptor Cooling Hose Assembly Temperature Sensor Line Remote Control Pump Kit XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Page 2 Xtreme Power Conversion XPC Corporation OPTIONS Ambient Air Adaptor Cooling Hose Assembly Exhaust Flange...

Page 3: ...the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any technical advice furnished by XPC Corporation or a XPC Corporation authorized representative before or after delivery with regard to the use or application of Xtreme Power Conversion equipment is furnished on the basis that it represents XPC Corporations bes...

Page 4: ...he outside of all packages Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes 4 Return the Xtreme Cooling unit by insured prepaid carrier to the address provided by the Technician Refer to the Warranty statements in this manual for additional details on what is covered XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY Xtreme Power Conversion XPC...

Page 5: ...ervice center Xtreme Power Conversion XPC Corporation Page 5 XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners OBTAINING SERVICE If the Xtreme Cooling unit requires Service 1 Use the TROUBLESHOOTING section in this manual to eliminate obvious causes 2 Verify there are no circuit breakers tripped 3 Call your dealer for assistance If you cannot reach your dealer or if they cannot resolve ...

Page 6: ...ea is not practical or possible A dedicated spot cooling thermostat controls the unit in this application These air conditioners can also be used in smaller areas for room cooling A control panel provides ease of use and contains self diagnostic functions and displays showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown...

Page 7: ... 0 x 24 4 x 50 4 22 0 x 24 4 x 50 4 Weight LBS 132 198 209 Current Consumption AMPS 11 5 11 0 10 0 15 0 14 0 Circuit Breaker Size AMPS 15 15 20 Power Consumption KW 1 4 2 3 3 1 Compressor Input KW 1 2 2 0 2 4 Air Flow High Low Evaporator CFM 357 285 464 393 571 500 Air Flow Condenser CFM 610 857 1142 Motor Input High Low Evaporator KW 0 091 0 089 0 24 0 20 0 13 0 11 Motor Input Condenser KW 0 08 0...

Page 8: ...e blockage from drain hose Remove any object stuck underneath of the black panel under the water tank The unit doesn t work Check the utility to verify that power is available to the unit Verify that the power cord is connected Reset the circuit breaker and restart the unit Connect the power cord No cold air flows from the cold air outlet Ambient air cannot be properly cooled if the filter is dirt...

Page 9: ...act a qualified service agent Replace compressor Condensate water level alarm Condensate tank is full Empty the water tank After installation of the water tank press the SPOT COOL or ROOM COOL button to resume operation Page 16 Xtreme Power Conversion XPC Corporation XC 14A XC 22A XC 30A USER S MANUAL Portable Air Conditioners Xtreme Power Conversion XPC Corporation Page 9 XC 14A XC 22A XC 30A USE...

Page 10: ...andles to a flat level surface and set the cater brakes to the locked position Plugging in the Unit Check the prongs and surface of the power cord plug for dust dirt If dust and or dirt are present wipe off with a clean dry cloth Check the power cord plug and prongs for damage or excess play If any damage or excess play is found contact a qualified repair technician or a qualified electrician to p...

Page 11: ...6 To clean the condenser filter lift up on the rear filter from the middle bar slightly and then angle the filter outwards from the bottom and remove 7 Use the same cleaning procedure as in steps 3 5 above 8 To replace the condenser filter place the top of the filter in the guide and slide the filter up until the bottom of the filter clears the frame Then push the bottom of the filter into the gui...

Page 12: ...d when abnormal operation occurs 8 TARGET TEMP Displays the unit set temperature for ROOM COOL mode only MAINTENANCE Filter Cleaning There are two filters in the unit The evaporator filter is located at the front of the unit The condenser filter is located in the rear of the unit see Figure 9 10 Pull the filter frame forward to remove the back filter Figure 7 Removing Rear Filter Remove dust from ...

Reviews: