Xtreme Power Conversion Corporation
JX-200 User’s Manual
Page 4
3.2 Selecting Installation Position
It is necessary to select a proper environment to install the unit, in order to minimize the possibility of damage to
the isolation transformer and extend the life of the isolation transformer. Please follow the instructions below:
1. Do not block the air-flow to the ventilation openings of the unit.
2. Please ensure the installation site environmental conditions are in accordance with the unit’s working
specifications to avoid overheat and excessive moisture.
3. Do not place the unit in a dusty or corrosive environment or near any flammable objects.
4. This unit is not designed for outdoor use.
3.3 Mounting the Ears
Attach mounting ears to the side mounting holes of isolation transformer using the screws provided. Refer to left
chart.
4. Specifications
MODEL NUMBER
JX-200
CAPACITY
Power rating
200VA (200W)
INPUT
Voltage
120VAC
Frequency
50/60Hz
Breaker
5A,125VAC
OUTPUT
Voltage
120VAC
Frequency
50/60Hz
Surge suppression
300 joules
Let-through Noise
<10 volts normal mode and < .5 volts common mode
PHYSICAL
Dimensions (W x D x H)
6.9 x 8.5 x 1.25 in (175 x 216 x 32 mm)
Weight
6.6 lbs(3.0 kg)
Line cord
C13 to 5–15P
Receptacles
(3) 5–15R
ENVIRONMENT
Temperature
32–104°F (0–40°C)
Humidity
0–95%
Altitude
11,500 feet above sea level
APPROVALS
UL60950 RoHS
COMMUNICATIONS INTERFACE
LED*2(green/red)
INCLUDED IN BOX
User manual
AVAILABLE OPTIONS
Line cord with offset right angle 5–15P